Diagnostic Accuracy of Loop-Mediated Isothermal Amplification (TB-LAMP) for Tuberculosis in Children

被引:6
|
作者
Promsena, Pathariya [1 ,2 ]
Jantarabenjakul, Watsamon [1 ,2 ,3 ]
Suntarattiwong, Piyarat [4 ]
Sudjaritruk, Tavitiya [5 ]
Anugulruengkitt, Suvaporn [1 ,2 ]
Rotcheewaphan, Suwatchareeporn [6 ,7 ]
Petsong, Suthidee [6 ]
Sawangsinth, Panadda [2 ]
Sophonphan, Jiratchaya [2 ]
Tawan, Monta [2 ]
Moonwong, Juthamanee [2 ]
Puthanakit, Thanyawee [1 ,2 ]
机构
[1] Chulalongkorn Univ, Fac Med, Dept Pediat, Rama 4 Rd, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Med, Ctr Excellence Pediat Infect Dis & Vaccines, Bangkok, Thailand
[3] King Chulalongkorn Mem Hosp, Thai Red Cross Emerging Infect Dis Clin Ctr, Bangkok, Thailand
[4] Queen Sirikit Natl Inst Child Hlth, Pediat Infect Dis Unit, Bangkok, Thailand
[5] Chiang Mai Univ, Fac Med, Dept Pediat, Chiang Mai, Thailand
[6] Chulalongkorn Univ, Fac Med, Dept Microbiol, Bangkok, Thailand
[7] Chulalongkorn Univ, Fac Med, Dept Med, TB Res Unit, Bangkok, Thailand
关键词
molecular diagnosis; pediatric tuberculosis; point-of-care; TB culture; TB-LAMP; MYCOBACTERIUM-TUBERCULOSIS; PULMONARY TUBERCULOSIS; ASSAY;
D O I
10.1093/jpids/piab097
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background Diagnosing tuberculosis (TB) in children is challenging due to its paucibacillary nature. Loop-mediated isothermal amplification (TB-LAMP) is a simple, rapid, and specific point-of-care molecular diagnostic test. However, evaluation of its performance remains limited in children. This study aimed to evaluate the diagnostic performance of Eiken TB-LAMP among children with presumed tuberculosis disease. Methods Pulmonary and extrapulmonary specimens were collected from children under 18 years with presumed TB. Each specimen was tested by using TB-LAMP, acid-fast bacilli (AFB) smear microscopy, and one of the two molecular assays (polymerase chain reaction [PCR] or Xpert MTB/RIF). Sensitivity and specificity were estimated compared to mycobacterial culture as reference standard. Results From January 2020 to January 2021, 75 participants with presumed TB were enrolled with median age of 7 years (IQR 2-12). Seventeen specimens from 16 (21.3%) children had bacteriologically confirmed TB: 10 pulmonary and 7 extrapulmonary specimens. Overall sensitivity and specificity of TB-LAMP was 76.5% (95% CI 50.1%-93.2%) and 100% (95% CI 94.3%-100%), respectively. It had significantly higher sensitivity than AFB (52.9%, 95% CI 27.8%-77.0%) and similar to other molecular assays; PCR 82.4% (95% CI 56.6%-96.2%), Xpert MTB/RIF 70.0% (95% CI 34.8%-93.3%). Sensitivity of TB-LAMP for pulmonary, lymph node tissue, and extrapulmonary fluid was 80% (95% CI 44.4%-97.5%), 100% (95% CI 39.8-100), and 33.3% (95% CI 0.8-90.6), respectively. TB-LAMP detected all smear-positive (N = 9) and 50% of smear-negative (N = 8) specimens. Conclusions TB-LAMP had higher sensitivity than AFB microscopy and accuracy similar to other molecular assays in both pulmonary and extrapulmonary specimens. These findings support using TB-LAMP as a point-of-care test in children.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 50 条
  • [31] Detection of toxigenic Clostridium difficile by Loop-Mediated Isothermal Amplification (LAMP)
    Jayaratne, P.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2014, 21 : 379 - 380
  • [32] Microfluidic continuous flow digital loop-mediated isothermal amplification (LAMP)
    Rane, Tushar D.
    Chen, Liben
    Zec, Helena C.
    Wang, Tza-Huei
    LAB ON A CHIP, 2015, 15 (03) : 776 - 782
  • [33] Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects
    Notomi, Tsugunori
    Mori, Yasuyoshi
    Tomita, Norihiro
    Kanda, Hidetoshi
    JOURNAL OF MICROBIOLOGY, 2015, 53 (01) : 1 - 5
  • [34] Development of Loop-Mediated Isothermal Amplification (LAMP) for Universal Detection of Enteroviruses
    Hua-Bing Zhao
    Guang-Ya Yin
    Guo-Ping Zhao
    Ai-Hua Huang
    Jun-Hong Wang
    Shuang-Feng Yang
    Hong-Sheng Gao
    Wei-Jun Kang
    Indian Journal of Microbiology, 2014, 54 : 80 - 86
  • [35] Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for detection of Leishmania DNA in buffy coat from visceral leishmaniasis patients
    Md Gulam Musawwir Khan
    Khondaker Rifat Hasan Bhaskar
    Md Abdus Salam
    Tania Akther
    Gerd Pluschke
    Dinesh Mondal
    Parasites & Vectors, 5 (1)
  • [36] Loop-mediated isothermal amplification (LAMP) shield for Arduino DNA detection
    Velders A.H.
    Schoen C.
    Saggiomo V.
    BMC Research Notes, 11 (1)
  • [37] SENSITIVE DETECTION OF MICRORNAS WITH SIMPLIFIED LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP)
    Li Zhengping
    Liu Xiaoling
    Li Cuiping
    Liu Ye
    Li Yankun
    PROGRESS ON POST-GENOME TECHNOLOGIES AND MODERN NATURAL PRODUCTS, 2011, 2011, : 384 - 386
  • [38] Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects
    Tsugunori Notomi
    Yasuyoshi Mori
    Norihiro Tomita
    Hidetoshi Kanda
    Journal of Microbiology, 2015, 53 : 1 - 5
  • [39] Polyethylene Glycol Accelerates Loop-mediated Isothermal Amplification (LAMP) Reaction
    Nose, Kenta
    Nagamine, Kentaro
    Tokuda, Junichi
    Takino, Junichi
    Honi, Takamitsu
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2013, 133 (10): : 1121 - 1126
  • [40] Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP)
    Zhang, Xuzhi
    Lowe, Stuart B.
    Gooding, John Justin
    BIOSENSORS & BIOELECTRONICS, 2014, 61 : 491 - 499