SHEAR WAVE ELASTOGRAPHY QUANTIFIES STIFFNESS IN EX VIVO PORCINE ARTERY WITH STIFFENED ARTERIAL REGION

被引:47
|
作者
Widman, Erik [1 ,2 ]
Maksuti, Elira [1 ,2 ]
Amador, Carolina [3 ]
Urban, Matthew W. [3 ,4 ]
Caidahl, Kenneth [2 ]
Larsson, Matilda [1 ,2 ]
机构
[1] KTH Royal Inst Technol, Sch Technol & Hlth, Dept Med Engn, Stockholm, Sweden
[2] Karolinska Inst, Dept Mol Med & Surg, Solna, Sweden
[3] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN USA
[4] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2016年 / 42卷 / 10期
基金
瑞典研究理事会;
关键词
Artery; Arteriosclerosis; Atherosclerosis; Elasticity; Ex vivo; Plaque; Phase velocity; Shear wave elastography; Ultrasound; RISK-ASSESSMENT STRATEGIES; CAROTID-ARTERY; RADIATION FORCE; VULNERABLE PLAQUE; BLOOD-PRESSURE; SOFT; ENDARTERECTOMY; DEFINITIONS; VALIDATION; ANISOTROPY;
D O I
10.1016/j.ultrasmedbio.2016.05.021
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Five small porcine aortas were used as a human carotid artery model, and their stiffness was estimated using shear wave elastography (SWE) in the arterial wall and a stiffened artery region mimicking a stiff plaque. To optimize the SWE settings, shear wave bandwidth was measured with respect to acoustic radiation force push length and number of compounded angles used for motion detection with plane wave imaging. The mean arterial wall and simulated plaque shear moduli varied from 41 +/- 5 to 97 +/- 10 kPa and from 86 +/- 13 to 174 +/- 35 kPa, respectively, over the pressure range 20-120 mmHg. The results revealed that a minimum bandwidth of approximately 1500 Hz is necessary for consistent shear modulus estimates, and a high pulse repetition frequency using no image compounding is more important than a lower pulse repetition frequency with better image quality when estimating arterial wall and plaque stiffness using SWE. (C) 2016 The Authors. Published by Elsevier Inc. on behalf ofWorld Federation for Ultrasound in Medicine& Biology.
引用
收藏
页码:2423 / 2435
页数:13
相关论文
共 50 条
  • [21] Shear wave elastography in ex vivo and in vivo skin using high-frequency ultrasound imaging
    Dayavansha, E. G. Sunethra
    Koch, Sheryl E.
    Rubinstein, Jack
    Mast, T. Douglas
    2020 IEEE 20TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE 2020), 2020, : 637 - 641
  • [22] Effect of renal perfusion and structural heterogeneity on shear wave elastography of the kidney: an in vivo and ex vivo study
    Xiaona Liu
    Na Li
    Tao Xu
    Fang Sun
    Rui Li
    Qimin Gao
    Lianxiang Chen
    Chaoyang Wen
    BMC Nephrology, 18
  • [23] Factors influencing the stiffness of fibroadenomas at shear wave elastography
    Elseedawy, M.
    Whelehan, P.
    Vinnicombe, S.
    Thomson, K.
    Evans, A.
    CLINICAL RADIOLOGY, 2016, 71 (01) : 92 - 95
  • [24] Testicular stiffness in varicocele: evaluation with shear wave elastography
    Turna, Onder
    Aybar, Mustafa Devran
    ULTRASONOGRAPHY, 2020, 39 (04) : 350 - 355
  • [25] Shear wave elastography imaging in a porcine tendinopathy model
    Quilling, Grant M.
    Lee, Kenneth S.
    Ebben, Beau
    SKELETAL RADIOLOGY, 2022, 51 (11) : 2167 - 2173
  • [26] Shear wave elastography imaging in a porcine tendinopathy model
    Grant M. Quilling
    Kenneth S. Lee
    Beau Ebben
    Skeletal Radiology, 2022, 51 : 2167 - 2173
  • [27] Ex Vivo Assessment of Sentinel Lymph Nodes in Breast Cancer Using Shear Wave Elastography
    Kilic, Fahrettin
    Velidedeoglu, Mehmet
    Ozturk, Tulin
    Kandemirli, Sedat Giray
    Dikici, Atilla Suleyman
    Er, Mehmet Emin
    Aydogan, Fatih
    Kantarci, Fatih
    Yilmaz, Mehmet Halit
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (02) : 271 - 277
  • [28] Measurement of shear wave speed dispersion in the placenta by transient elastography: A preliminary ex vivo study
    Simon, Emmanuel G.
    Calle, Samuel
    Perrotin, Franck
    Remenieras, Jean-Pierre
    PLOS ONE, 2018, 13 (04):
  • [29] Quantification of regional aortic stiffness using MR elastography: A phantom and ex-vivo porcine aorta study
    Zhang, Nan
    Chen, Jun
    Yin, Meng
    Glaser, Kevin J.
    Xu, Lei
    Ehman, Richard L.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 91 - 96
  • [30] Assessment of the common carotid artery wall stiffness by Shear Wave Elastography in Behcet's disease
    Alis, Deniz
    Durmaz, Emine Sebnem Memis
    Alis, Ceren
    Tutuncu, Melih
    Saip, Sabahattin
    Kocer, Naci
    Islak, Civan
    Kizilkilic, Osman
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (04) : 446 - 452