High-Contrast Lumbar Spinal Bone Imaging Using a 3D Slab-Selective UTE Sequence

被引:9
|
作者
Afsahi, Amir Masoud [1 ]
Lombardi, Alecio F. [1 ,2 ]
Wei, Zhao [1 ]
Carl, Michael [3 ]
Athertya, Jiyo [1 ]
Masuda, Koichi [4 ]
Wallace, Mark [5 ]
Lee, Roland R. [1 ,2 ]
Ma, Ya-Jun [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Vet Affairs San Diego Healthcare Syst, Res Serv, San Diego, CA USA
[3] GE Healthcare, San Diego, CA USA
[4] Univ Calif San Diego, Dept Orthped Surg, San Diego, CA 92103 USA
[5] Univ Calif San Diego, Dept Anesthesiol, San Diego, CA 92103 USA
来源
FRONTIERS IN ENDOCRINOLOGY | 2022年 / 12卷
关键词
UTE MRI; bone imaging; lumbar spine; slab selective; CT-like contrast; ZTE MRI; MAGNETIC-RESONANCE; TIME; MRI;
D O I
10.3389/fendo.2021.800398
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ultra-short echo time (UTE) MRI with post-processing is a promising technique in bone imaging that produces a similar contrast to computed tomography (CT). Here, we propose a 3D slab-selective ultrashort echo time (UTE) sequence together with image post-processing to image bone structures in the lumbar spine. We also explore the intermodality agreement between the UTE and CT images. The lumbar spines of two healthy volunteers were imaged with 3D UTE using five different resolutions to determine the best imaging protocol. Then, four patients with low back pain were imaged with both the 3D UTE sequence and CT to investigate agreement between the imaging methods. Two other patients with low back pain were then imaged with the 3D UTE sequence and clinical conventional T-1-weighted and T-2-weighted fast spin-echo (FSE) MRI sequences for qualitative comparison. The 3D UTE sequence together with post-processing showed high contrast images of bone and high intermodality agreement with CT images. In conclusion, post-processed slab-selective UTE imaging is a feasible approach for highlighting bone structures in the lumbar spine and demonstrates significant anatomical correlation with CT images.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] UTE-SENCEFUL: first results for 3D high-resolution lung ventilation imaging
    Pereira, L. Mendes
    Wech, T.
    Weng, A. M.
    Kestler, C.
    Veldhoen, S.
    Bley, T. A.
    Koestler, H.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2464 - 2473
  • [32] Imaging of the region of the osteochondral junction (OCJ) using a 3D adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-cones) sequence at 3 T
    Ma, Ya-Jun
    Jerban, Saeed
    Carl, Michael
    Wan, Lidi
    Guo, Tan
    Jang, Hyungseok
    Bydder, Graeme M.
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2019, 32 (05)
  • [33] Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis
    Bastiaan Moraal
    Stefan D. Roosendaal
    Petra J. W. Pouwels
    Hugo Vrenken
    Ronald A. van Schijndel
    Dominik S. Meier
    Charles R. G. Guttmann
    Jeroen J. G. Geurts
    Frederik Barkhof
    European Radiology, 2008, 18
  • [34] Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis
    Moraal, Bastiaan
    Roosendaal, Stefan D.
    Pouwels, Petra J. W.
    Vrenken, Hugo
    Van Schijndel, Ronald A.
    Meier, Dominik S.
    Guttmann, Charles R. G.
    Geurts, Jeroen J. G.
    Barkhof, Frederik
    EUROPEAN RADIOLOGY, 2008, 18 (10) : 2311 - 2320
  • [35] Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis
    Moraal, Bastiaan
    Roosendaal, Stefan D.
    Pouwels, Petra J. W.
    Vrenken, Hugo
    van Schijndel, Ronald A.
    Meier, Dominik S.
    Guttmann, Charles R. G.
    Geurts, Jeroen J. G.
    Barkhof, Frederik
    NEURORADIOLOGY JOURNAL, 2009, 22 : 33 - 42
  • [36] 3D imaging of polycrystalline structure using diffraction contrast tomography
    Hirayama K.
    Keikinzoku/Journal of Japan Institute of Light Metals, 2019, 69 (12): : 587 - 590
  • [37] High-Contrast Optical Modulation from Strain-Induced Nanogaps at 3D Heterogeneous Interfaces
    Cho, Donghwi
    Shim, Young-Seok
    Jung, Jae-Wook
    Nam, Sang-Hyeon
    Min, Seokhwan
    Lee, Sang-Eon
    Ham, Youngjin
    Lee, Kwangjae
    Park, Junyong
    Shin, Jonghwa
    Hong, Jung-Wuk
    Jeon, Seokwoo
    ADVANCED SCIENCE, 2020, 7 (11)
  • [38] 4D-MRI with 3D Radial Sampling and Self-Gating-Based K-Space Sorting: Image Quality Improvement by Slab-Selective Excitation
    Deng, Z.
    Yang, W.
    Pang, J.
    Tuli, R.
    Bi, X.
    Hakimian, B.
    Fraass, B.
    Li, D.
    Fan, Z.
    MEDICAL PHYSICS, 2016, 43 (06) : 3721 - 3721
  • [39] High-contrast, speckle-free, true 3D holography via binary CGH optimization
    Byounghyo Lee
    Dongyeon Kim
    Seungjae Lee
    Chun Chen
    Byoungho Lee
    Scientific Reports, 12
  • [40] Short T2 imaging using a 3D double adiabatic inversion recovery prepared ultrashort echo time cones (3D DIR-UTE-Cones) sequence
    Ma, Ya-Jun
    Zhu, Yanchun
    Lu, Xing
    Carl, Michael
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2555 - 2563