Safety and efficacy of the Pipeline Embolization Device in 100 small intracranial aneurysms

被引:117
|
作者
Chalouhi, Nohra [1 ,2 ]
Zanaty, Mario [1 ,2 ]
Whiting, Alex [1 ,2 ]
Yang, Steven [1 ,2 ]
Tjoumakaris, Stavropoula [1 ,2 ]
Hasan, David [3 ]
Starke, Robert M. [4 ]
Hann, Shannon [1 ,2 ]
Hammer, Christine [1 ,2 ]
Kung, David [1 ,2 ]
Rosenwasser, Robert [1 ,2 ]
Jabbour, Pascal [1 ,2 ]
机构
[1] Thomas Jefferson Univ, Dept Neurol Surg, Philadelphia, PA 19107 USA
[2] Jefferson Hosp Neurosci, Philadelphia, PA USA
[3] Univ Iowa, Dept Neurosurg, Iowa City, IA USA
[4] Univ Virginia, Dept Neurol Surg, Charlottesville, VA USA
关键词
intracranial aneurysm; flow diversion; Pipeline Embolization Device; small aneurysm; vascular disorders; SINGLE-CENTER EXPERIENCE; TERM-FOLLOW-UP; CEREBRAL ANEURYSMS; SACCULAR ANEURYSMS; FLOW DIVERSION; COMPLICATIONS; PREDICTORS; COILING; MIDTERM;
D O I
10.3171/2014.12.JNS14411
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECT Flow diverters are increasingly used for treatment of intracranial aneurysms. In most series, the Pipeline Embolization Device (PED) was used for the treatment of large, giant, complex, and fusiform aneurysms. Little is known about the use of the PED in small aneurysms. The purpose of this study was to assess the safety and efficacy of the PED in small aneurysms (<= 7 mm). METHODS A total of 100 consecutive patients were treated with the PED at the authors' institution between May 2011 and September 2013. Data on procedural safety and efficacy were retrospectively collected. RESULTS The mean aneurysm size was 5.2 +/- 1.5 mm. Seven patients (7%) had sustained a subarachnoid hemorrhage. All except 5 aneurysms (95%) arose from the anterior circulation. The number of PEDs used was 1.2 per aneurysm. Symptomatic procedure-related complications occurred in 3 patients (3%): 1 distal parenchymal hemorrhage that was managed conservatively and 2 ischemic events. At the latest follow-up (mean 6.3 months), 54 (72%) aneurysms were completely occluded (100%), 10 (13%) were nearly completely occluded (>= 90%), and 11(15%) were incompletely occluded (< 90%). Six aneurysms (8%) required further treatment. Increasing aneurysm size (OR 3.8, 95% CI 0.99-14; p = 0.05) predicted retreatment. All patients achieved a favorable outcome (modified Rankin Scale Score 0-2) at follow-up. CONCLUSIONS In this study, treatment of small aneurysms with the PED was associated with low-complication rates and high aneurysm-occlusion rates. These findings suggest that the PED is a safe and effective alternative to conventional endovascular techniques for small aneurysms. Randomized trials with long-term follow-up are necessary to determine the optimal treatment that leads to the highest rate of obliteration and the best clinical outcomes.
引用
收藏
页码:1498 / 1502
页数:5
相关论文
共 50 条
  • [31] Use of Coils in Conjunction With the Pipeline Embolization Device for Treatment of Intracranial Aneurysms
    Lin, Ning
    Brouillard, Adam M.
    Krishna, Chandan
    Mokin, Maxim
    Natarajan, Sabareesh K.
    Sonig, Ashish
    Snyder, Kenneth V.
    Levy, Elad I.
    Siddiqui, Adnan H.
    NEUROSURGERY, 2015, 76 (02) : 142 - 149
  • [32] Current Status of Pipeline Embolization Device in the Treatment of Intracranial Aneurysms: A Review
    Tse, Mona M. Y.
    Yan, Bernard
    Dowling, Richard J.
    Mitchell, Peter J.
    WORLD NEUROSURGERY, 2013, 80 (06) : 829 - 835
  • [33] The first decade of flow diversion for intracranial aneurysms with the Pipeline embolization device
    Monteiro, Andre
    Lim, Jaims
    Siddiqi, Manhal
    Donnelly, Brianna M.
    Khawar, Wasiq
    Baig, Ammad
    Turner, Ryan C.
    Bouslama, Mehdi
    Raygor, Kunal P.
    Lai, Pui Man Rosalind
    Housley, Steven B.
    Davies, Jason M.
    Snyder, Kenneth V.
    Siddiqui, Adnan H.
    Levy, Elad I.
    NEUROSURGICAL FOCUS, 2023, 54 (05)
  • [34] Definitive reconstruction of circumferential fusiform intracranial aneurysms with the pipeline embolization device
    Fiorella, David
    Woo, Henry H.
    Albuquerque, Felipe C.
    Nelson, Peter K.
    NEUROSURGERY, 2008, 62 (05) : 1115 - 1120
  • [35] Retreatment of previously flow diverted intracranial aneurysms with the pipeline embolization device
    Lauzier, David C.
    Cler, Samuel J.
    Chatterjee, Arindam R.
    Osbun, Joshua W.
    Moran, Christopher J.
    Kansagra, Akash P.
    INTERVENTIONAL NEURORADIOLOGY, 2022, : 710 - 714
  • [37] Canadian Experience with the Pipeline Embolization Device for Repair of Unruptured Intracranial Aneurysms
    O'Kelly, C. J.
    Spears, J.
    Chow, M.
    Wong, J.
    Boulton, M.
    Weill, A.
    Willinsky, R. A.
    Kelly, M.
    Marotta, T. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (02) : 381 - 387
  • [38] Treatment of Intracranial Aneurysms with Pipeline Embolization Device: A Systematic Review of Literature
    Murthy, Santosh
    Shah, Shreyansh
    Rao, Chethan Venkatasubba
    Bershad, Eric
    Suarez, Jose
    NEUROLOGY, 2013, 80
  • [39] Safety of the Pipeline Embolization Device in Treatment of Posterior Circulation Aneurysms
    Phillips, T. J.
    Wenderoth, J. D.
    Phatouros, C. C.
    Rice, H.
    Singh, T. P.
    Devilliers, L.
    Wycoco, V.
    Meckel, S.
    McAuliffe, W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (07) : 1225 - 1231
  • [40] Pipeline Embolization Device for Pericallosal Artery Aneurysms: A Retrospective Single Center Safety and Efficacy Study
    Rodrigues, Katyucia De Macedo
    Kuhn, Anna Luisa
    Tamura, Takamitsu
    Dabus, Guilherme
    Kan, Peter
    Marosfoi, Miklos G.
    Lozano, J. Diego
    Perras, Mary
    Brooks, Christopher
    Howk, Mary C.
    Hou, Samuel Y.
    Rex, David E.
    Massari, Francesco
    Gounis, Matthew J.
    Wakhloo, Ajay K.
    Puri, Ajit S.
    OPERATIVE NEUROSURGERY, 2018, 14 (04) : 351 - 358