Evaluation of EEG Headset Mounting for Brain-Computer Interface-Based Stroke Rehabilitation by Patients, Therapists, and Relatives

被引:18
|
作者
Jochumsen, Mads [1 ]
Knoche, Hendrik [2 ]
Kidmose, Preben [3 ]
Kjaer, Troels Wesenberg [4 ]
Dinesen, Birthe Irene [5 ]
机构
[1] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[2] Aalborg Univ, Dept Architecture Design & Media Technol, Aalborg, Denmark
[3] Aarhus Univ, Dept Engn Bioelect Instrumentat & Signal Proc, Aarhus, Denmark
[4] Zealand Univ Hosp, Dept Neurol, Roskilde, Denmark
[5] Aalborg Univ, Lab Welf Technol Telehlth & Telerehabil, Dept Hlth Sci & Technol, Aalborg, Denmark
来源
关键词
brain-computer interface; stroke rehabilitation; usability; EEG headset; technology transfer; DESIGN;
D O I
10.3389/fnhum.2020.00013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Brain-computer interfaces (BCIs) have successfully been used for motor recovery training in stroke patients. However, the setup of BCI systems is complex and may be divided into (1) mounting the headset and (2) calibration of the BCI. One of the major problems is mounting the headset for recording brain activity in a stroke rehabilitation context, and usability testing of this is limited. In this study, the aim was to compare the translational aspects of mounting five different commercially available headsets from a user perspective and investigate the design considerations associated with technology transfer to rehabilitation clinics and home use. No EEG signals were recorded, so the effectiveness of the systems have not been evaluated. Three out of five headsets covered the motor cortex which is needed to pick up movement intentions of attempted movements. The other two were as control and reference for potential design considerations. As primary stakeholders, nine stroke patients, eight therapists and two relatives participated; the stroke patients mounted the headsets themselves. The setup time was recorded, and participants filled in questionnaires related to comfort, aesthetics, setup complexity, overall satisfaction, and general design considerations. The patients had difficulties in mounting all headsets except for a headband with a dry electrode located on the forehead (control). The therapists and relatives were able to mount all headsets. The fastest headset to mount was the headband, and the most preferred headsets were the headband and a behind-ear headset (control). The most preferred headset that covered the motor cortex used water-based electrodes. The patients reported that it was important that they could mount the headset themselves for them to use it every day at home. These results have implications for design considerations for the development of BCI systems to be used in rehabilitation clinics and in the patient's home.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Development of a Brain-Computer Interface-Based Symbol Digit Modalities Test and Validation in Healthy Elderly Volunteers and Stroke Patients
    Chen, Xiaogang
    Hu, Nan
    Gao, Xiaorong
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2022, 30 : 1433 - 1440
  • [22] Comprehensive Evaluation of Stroke Rehabilitation Dynamics: Integrating Brain-Computer Interface with Robotized Orthesic Hand and Longitudinal EEG Changes
    Vales, Yolanda
    Catalan, Jose M.
    Blanco-Ivorra, Andrea
    Barios, Juan A.
    Garcia-Aracil, Nicolas
    ARTIFICIAL INTELLIGENCE FOR NEUROSCIENCE AND EMOTIONAL SYSTEMS, PT I, IWINAC 2024, 2024, 14674 : 171 - 181
  • [23] Effects of brain-computer interface-based functional electrical stimulation on balance and gait function in patients with stroke: preliminary results
    Chung, EunJung
    Park, Sang-In
    Jang, Yun-Yung
    Lee, Byoung-Hee
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (02) : 513 - 516
  • [24] Brain-Computer Interface for Lower Extremity Rehabilitation in Chronic Stroke
    Sieghartsleitner, S.
    Fernandes, F.
    Sebastian-Romagosa, M.
    Cho, W.
    Ortner, R.
    Guger, C.
    EUROPEAN JOURNAL OF NEUROLOGY, 2023, 30 : 280 - 280
  • [25] eConHand: A Wearable Brain-Computer Interface System for Stroke Rehabilitation
    Qin, Zhun
    Xu, Yao
    Shu, Xiaokang
    Hua, Lei
    Sheng, Xinjun
    Zhu, Xiangyang
    2019 9TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2019, : 734 - 737
  • [26] Performance assessment in brain-computer interface-based augmentative and alternative communication
    David E Thompson
    Stefanie Blain-Moraes
    Jane E Huggins
    BioMedical Engineering OnLine, 12
  • [27] Performance assessment in brain-computer interface-based augmentative and alternative communication
    Thompson, David E.
    Blain-Moraes, Stefanie
    Huggins, Jane E.
    BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [28] EEG and MEG brain-computer interface for tetraplegic patients
    Kauhanen, Laura
    Nykopp, Tommi
    Lehtonen, Janne
    Jylanki, Pasi
    Heikkonen, Jukka
    Rantanen, Pekka
    Alaranta, Hannu
    Sams, Mikko
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (02) : 190 - 193
  • [29] Brain-Computer Interface Based on Ear-EEG
    Hwang, Han-Jeong
    2021 9TH IEEE INTERNATIONAL WINTER CONFERENCE ON BRAIN-COMPUTER INTERFACE (BCI), 2021, : 60 - 62
  • [30] Neurological rehabilitation of stroke patients via motor imaginary-based brain-computer interface technology
    Sun, Hongyu
    Xiang, Yang
    Yang, Mingdao
    NEURAL REGENERATION RESEARCH, 2011, 6 (28) : 2198 - 2202