Evaluation of EEG Headset Mounting for Brain-Computer Interface-Based Stroke Rehabilitation by Patients, Therapists, and Relatives

被引:18
|
作者
Jochumsen, Mads [1 ]
Knoche, Hendrik [2 ]
Kidmose, Preben [3 ]
Kjaer, Troels Wesenberg [4 ]
Dinesen, Birthe Irene [5 ]
机构
[1] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[2] Aalborg Univ, Dept Architecture Design & Media Technol, Aalborg, Denmark
[3] Aarhus Univ, Dept Engn Bioelect Instrumentat & Signal Proc, Aarhus, Denmark
[4] Zealand Univ Hosp, Dept Neurol, Roskilde, Denmark
[5] Aalborg Univ, Lab Welf Technol Telehlth & Telerehabil, Dept Hlth Sci & Technol, Aalborg, Denmark
来源
关键词
brain-computer interface; stroke rehabilitation; usability; EEG headset; technology transfer; DESIGN;
D O I
10.3389/fnhum.2020.00013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Brain-computer interfaces (BCIs) have successfully been used for motor recovery training in stroke patients. However, the setup of BCI systems is complex and may be divided into (1) mounting the headset and (2) calibration of the BCI. One of the major problems is mounting the headset for recording brain activity in a stroke rehabilitation context, and usability testing of this is limited. In this study, the aim was to compare the translational aspects of mounting five different commercially available headsets from a user perspective and investigate the design considerations associated with technology transfer to rehabilitation clinics and home use. No EEG signals were recorded, so the effectiveness of the systems have not been evaluated. Three out of five headsets covered the motor cortex which is needed to pick up movement intentions of attempted movements. The other two were as control and reference for potential design considerations. As primary stakeholders, nine stroke patients, eight therapists and two relatives participated; the stroke patients mounted the headsets themselves. The setup time was recorded, and participants filled in questionnaires related to comfort, aesthetics, setup complexity, overall satisfaction, and general design considerations. The patients had difficulties in mounting all headsets except for a headband with a dry electrode located on the forehead (control). The therapists and relatives were able to mount all headsets. The fastest headset to mount was the headband, and the most preferred headsets were the headband and a behind-ear headset (control). The most preferred headset that covered the motor cortex used water-based electrodes. The patients reported that it was important that they could mount the headset themselves for them to use it every day at home. These results have implications for design considerations for the development of BCI systems to be used in rehabilitation clinics and in the patient's home.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Brain-Computer Interface-Based Soft Robotic Glove Rehabilitation for Stroke
    Cheng, Nicholas
    Phua, Kok Soon
    Lai, Hwa Sen
    Tam, Pui Kit
    Tang, Ka Yin
    Cheng, Kai Kei
    Yeow, Raye Chen-Hua
    Ang, Kai Keng
    Guan, Cuntai
    Lim, Jeong Hoon
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (12) : 3339 - 3351
  • [2] Brain-computer interface in stroke rehabilitation
    Ang, Kai Keng
    Guan, Cuntai
    Journal of Computing Science and Engineering, 2013, 7 (02) : 139 - 146
  • [3] Brain-Computer Interface Based Stroke Rehabilitation For Hemiplegia
    Triponyuwasin, Preechapawan
    Wongsawat, Yodchanan
    2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2014,
  • [4] Movement-Related Electroencephalography in Stroke Patients Across a Brain-Computer Interface-Based Intervention
    Castro-Aparicio, Juan C.
    Carino-Escobar, Ruben, I
    Cantillo-Negrete, Jessica
    COMPUTATIONAL NEUROSCIENCE, LAWCN 2021, 2022, 1519 : 215 - 224
  • [5] Brain-computer interface treatment for gait rehabilitation in stroke patients
    Sebastian-Romagosa, Marc
    Cho, Woosang
    Ortner, Rupert
    Sieghartsleitner, Sebastian
    Von Oertzen, Tim J.
    Kamada, Kyousuke
    Laureys, Steven
    Allison, Brendan Z.
    Guger, Christoph
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [6] A Motor Imagery Based Brain-Computer Interface for Stroke Rehabilitation
    Ortner, R.
    Irimia, D. -C.
    Scharinger, J.
    Guger, C.
    ANNUAL REVIEW OF CYBERTHERAPY AND TELEMEDICINE, 2012, 10 : 319 - 323
  • [7] Brain-Computer Interface-based (BCI) based arm robotic rehabilitation for Stroke: A feasibility study and randomized controlled trial
    Chua, Karen
    Guan, Cuntai
    Ang, Kai Keng
    Kuah, Christopher
    Phua, Kok Soon
    Wang, Chuanchu
    Zhang, Haihong
    Lee, Jeanette
    Arul, Earnest
    Low, Wilson
    Ang, Beng Ti
    Kong, Keng-He
    BRAIN INJURY, 2012, 26 (4-5) : 492 - 493
  • [8] A Novel Deep Learning Method Based on an Overlapping Time Window Strategy for Brain-Computer Interface-Based Stroke Rehabilitation
    Cao, Lei
    Wu, Hailiang
    Chen, Shugeng
    Dong, Yilin
    Zhu, Changming
    Jia, Jie
    Fan, Chunjiang
    BRAIN SCIENCES, 2022, 12 (11)
  • [9] A Hybrid Brain-Computer Interface-Based Mail Client
    Yu, Tianyou
    Li, Yuanqing
    Long, Jinyi
    Li, Feng
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [10] Brain-Computer Interface-Based Humanoid Control: A Review
    Chamola, Vinay
    Vineet, Ankur
    Nayyar, Anand
    Hossain, Eklas
    SENSORS, 2020, 20 (13) : 1 - 23