On-orbit performance of the Compact Infrared Camera(CIRC) with uncooled infrared detector

被引:4
|
作者
Katayama, Haruyoshi [1 ]
Sakai, Michito [1 ]
Kato, Eri [1 ]
Nakajima, Yasuhoiro [1 ]
Nakau, Koji [2 ]
Kimura, Toshiyoshi [1 ]
机构
[1] Japan Aerosp Explorat Agcy, Tsukuba, Ibaraki 3058505, Japan
[2] Hokkaido Univ, Kita Ku, Sapporo, Hokkaido 0608628, Japan
来源
关键词
remote sensing; thermal infrared imaging; microbolometer; wildfire; ALOS-2;
D O I
10.1117/12.2179764
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed the Compact Infrared Camera (CIRC) with an uncooled infrared array detector (microbolometer) for space application. Microbolometers have an advantage of not requiring cooling system such as a mechanical cooler, and is suitable for resource-limited sensor system. Another characteristic of the CIRC is its use of athermal optics. The athermal optics system compensates for defocus owing to temperature changes. We also employ a shutter-less system which is a method to correct non-uniformity of the detector without a mechanical shutter. The CIRC achieves a small size (approximately 200 mm), light mass (approximately 3 kg), and low electrical power consumption (<20 W) by employing athermal optics and a shutterless system. The CIRC is launched in May 2014 as a technology-demonstration payload of Advanced Land Observation Satellite-2 (ALOS-2). Since the initial functional verification phase (July 4-14, 2014), the CIRC was demonstrated a function according to its intended design. We also confirmed the temperature accuracy of the CIRC observation data is within +/- 4K in the calibration validation phase after the initial functional verification phase. The CIRC also detected wildfires in various areas and observed the volcano activities in the operational phase. In this paper, we present the on-orbit performance of the CIRC onboard ALOS-2.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Design of a Handheld infrared imaging device based on Uncooled Infrared Detector
    Sun XianZhong
    Li Junwei
    Zhang YaZhou
    SECOND INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2017, 10256
  • [22] HIGH-SPEED UNCOOLED INFRARED DETECTOR
    BENDITSKII, AA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1986, 29 (04) : 956 - 957
  • [23] On-Orbit Calibration Data-Processing Technologies for the Space-Based Infrared Camera
    Zhang, Yin
    Cong, Mingyu
    Hao, Shijing
    Zhou, Yuxing
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2015, 53 (12): : 6372 - 6384
  • [24] An evaluation of the performance of an uncooled microbolometer array infrared camera for transient thermography NDE
    Pickering, S. G.
    Almond, D. P.
    NONDESTRUCTIVE TESTING AND EVALUATION, 2007, 22 (2-3) : 63 - 70
  • [25] Design and Implementation of a High-Performance Readout Circuit for Uncooled Infrared Detector
    Yuan, Honghui
    Chen, Shijun
    Zhai, Houming
    Chen, Yongping
    AOPC 2015: OPTICAL AND OPTOELECTRONIC SENSING AND IMAGING TECHNOLOGY, 2015, 9674
  • [26] Infrared on-orbit RCC inspection system (IORIS)
    Gazarik, MJ
    Antill, CW
    Johnson, DG
    Stephan, RA
    Vipavetz, KG
    Pandolf, JE
    Kist, EH
    Tappan, ND
    Winfree, WP
    Teter, J
    Haakenson, D
    Hinds, D
    Backer, B
    Wickman, H
    Harris, M
    Thermosense XXVII, 2005, 5782 : 303 - 314
  • [27] Analysis on Optical System Performance of A Strap-down Uncooled Infrared Detector
    Zhang, Zhan
    He, Guanglin
    Xiao, Pan
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND COMPUTER SCIENCE, 2016, 80 : 603 - 607
  • [28] Performance of 320 x 240 bolometer-type uncooled infrared detector
    Oda, N
    Tanaka, Y
    Sasaki, T
    Ajisawa, A
    Kawahara, A
    Kurashina, S
    NEC RESEARCH & DEVELOPMENT, 2003, 44 (02): : 170 - 174
  • [29] Overview of the advanced camera for surveys on-orbit performance
    Ford, H
    Clampin, M
    Hartig, G
    Illingworth, G
    Sirianni, M
    Martel, A
    Meurer, G
    McCann, J
    Sullivan, P
    Bartko, F
    Benitez, N
    Blakeslee, J
    Bouwens, R
    Broadhurst, T
    Brown, R
    Burrows, C
    Campbell, D
    Cheng, E
    Feldman, P
    Franx, M
    Golimowski, D
    Gronwall, C
    Kimble, R
    Krist, J
    Lesser, M
    Magee, D
    Miley, G
    Postman, M
    Rafal, M
    Rosati, P
    Sparks, W
    Tran, H
    Tsvetanov, Z
    Volmer, P
    White, R
    Woodruff, R
    FUTURE EUV/UV AND VISIBLE SPACE ASTROPHYSICS MISSIONS AND INSTRUMENTATION, 2003, 4854 : 81 - 94
  • [30] Microbolometer uncooled infrared camera with 20 mK NETD
    Radford, W
    Wyles, R
    Wyles, J
    Ray, M
    Kennedy, A
    Finch, A
    Moody, E
    Cheung, F
    Coda, R
    Baur, S
    INFRARED TECHNOLOGY AND APPLICATIONS XXIV, PTS 1-2, 1998, 3436 : 636 - 646