MR-based respiratory and cardiac motion correction for PET imaging

被引:60
|
作者
Kuestner, Thomas [1 ,2 ]
Schwartz, Martin [1 ,3 ]
Martirosian, Petros [3 ]
Gatidis, Sergios [2 ]
Seith, Ferdinand [2 ]
Gilliam, Christopher [4 ]
Blu, Thierry [4 ]
Fayad, Hadi [5 ]
Visvikis, Dimitris [5 ]
Schick, F. [3 ]
Yang, B. [1 ]
Schmidt, H. [2 ]
Schwenzer, N. F. [2 ]
机构
[1] Univ Stuttgart, Inst Signal Proc & Syst Theory, Stuttgart, Germany
[2] Univ Tubingen, Dept Radiol, Tubingen, Germany
[3] Univ Tubingen, Sect Expt Radiol, Tubingen, Germany
[4] Chinese Univ Hong Kong, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
[5] Univ Bretagne, INSERM, U1101, LaTIM, Brest, France
关键词
PET/MR motion correction; Respiratory and cardiac motion correction; Image registration; Gadgetron; RECONSTRUCTION; TIME; NAVIGATOR; PET/MRI; HEART; LIVER; REGISTRATION; COMBINATION; MOVEMENTS; SEQUENCE;
D O I
10.1016/j.media.2017.08.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: To develop a motion correction for Positron-Emission-Tomography (PET) using simultaneously acquired magnetic-resonance (MR) images within 90 s. Methods: A 90 s MR acquisition allows the generation of a cardiac and respiratory motion model of the body trunk. Thereafter, further diagnostic MR sequences can be recorded during the PET examination without any limitation. To provide full PET scan time coverage, a sensor fusion approach maps external motion signals (respiratory belt, ECG-derived respiration signal) to a complete surrogate signal on which the retrospective data binning is performed. A joint Compressed Sensing reconstruction and motion estimation of the subsampled data provides motion-resolved MR images (respiratory + cardiac). A 1-POINT DIXON method is applied to these MR images to derive a motion-resolved attenuation map. The motion model and the attenuation map are fed to the Customizable and Advanced Software for Tomographic Reconstruction (CASToR) PET reconstruction system in which the motion correction is incorporated. All reconstruction steps are performed online on the scanner via Gadgetron to provide a clinically feasible setup for improved general applicability. The method was evaluated on 36 patients with suspected liver or lung metastasis in terms of lesion quantification (SUVmax, SNR, contrast), delineation (FWHM, slope steepness) and diagnostic confidence level (3-point Likert-scale). Results: A motion correction could be conducted for all patients, however, only in 30 patients moving lesions could be observed. For the examined 134 malignant lesions, an average improvement in lesion quantification of 22%, delineation of 64% and diagnostic confidence level of 23% was achieved. Conclusion: The proposed method provides a clinically feasible setup for respiratory and cardiac motion correction of PET data by simultaneous short-term MRI. The acquisition sequence and all reconstruction steps are publicly available to foster multi-center studies and various motion correction scenarios. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 144
页数:16
相关论文
共 50 条
  • [21] Errors in MR-based attenuation correction for brain imaging with PET/MR scanners
    Kops, Elena Rota
    Herzog, Hans
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 104 - 107
  • [22] MR Image-based PET Respiratory Motion Correction in PET/MR
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    Wan, Ming Young Simon
    O'Meara, Celia
    Atkinson, David
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [23] MR-Based PET Motion Correction Procedure for Simultaneous MR-PET Neuroimaging of Human Brain
    Ullisch, Marcus Goerge
    Scheins, Juergen Johann
    Weirich, Christoph
    Kops, Elena Rota
    Celik, Abdullah
    Tellmann, Lutz
    Stoecker, Tony
    Herzog, Hans
    Shah, Nadim Jon
    PLOS ONE, 2012, 7 (11):
  • [24] Validations for MR-based partial volume correction for brain PET imaging
    Matsubara, Keisuke
    Ibaraki, Masanobu
    Maeda, Tetsuya
    Kinoshita, Toshibumi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [25] MR-BASED ATTENUATION MAP RE-ALIGNMENT AND MOTION CORRECTION IN SIMULTANEOUS BRAIN MR-PET IMAGING
    Sforazzini, Francesco
    Chen, Zhaolin
    Baran, Jakub
    Bradley, Jason
    Carey, Alexandra
    Shah, N. Jon
    Egan, Gary
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 231 - 234
  • [26] MR-based truncation and attenuation correction in integrated PET/MR hybrid imaging using HUGE with continuous table motion
    Lindemann, Maike E.
    Oehmigen, Mark
    Blumhagen, Jan O.
    Gratz, Marcel
    Quick, Harald H.
    MEDICAL PHYSICS, 2017, 44 (09) : 4559 - 4572
  • [27] Possible errors with MR-based attenuation correction for brain imaging in PET/MR scanners
    Kops, Elena Rota
    Herzog, Hans
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [28] 4D tagged MR-based motion correction in simultaneous PET-MR
    Chun, Se Young
    Reese, Timothy
    Guerin, Bastien
    Zhu, Xuping
    Cho, Sanghee
    Ouyang, Jinsong
    Catana, Ciprian
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [29] MR-based attenuation correction in cardiovascular PET/MR imaging: challenges and practical solutions for cardiorespiratory motion and tissue class segmentation
    Karakatsanis, Nicolas
    Robson, Philip
    Dweck, Marc
    Abgral, Ronan
    Trivieri, Maria
    Sanz, Javier
    Contreras, Johanna
    Narula, Jagat
    Padilla, Maria
    Gidwani, Umesh
    Fuster, Valentin
    Kovacic, Jason
    Fayad, Zahi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [30] The effect of positioning aids on PET quantification following MR-based attenuation correction (AC) in PET/MR imaging
    Mantlik, Frederic
    Hofmann, Matthias
    Kupferschlaeger, Juergen
    Werner, Matthias
    Pichler, Bernd
    Beyer, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51