MR-based respiratory and cardiac motion correction for PET imaging

被引:60
|
作者
Kuestner, Thomas [1 ,2 ]
Schwartz, Martin [1 ,3 ]
Martirosian, Petros [3 ]
Gatidis, Sergios [2 ]
Seith, Ferdinand [2 ]
Gilliam, Christopher [4 ]
Blu, Thierry [4 ]
Fayad, Hadi [5 ]
Visvikis, Dimitris [5 ]
Schick, F. [3 ]
Yang, B. [1 ]
Schmidt, H. [2 ]
Schwenzer, N. F. [2 ]
机构
[1] Univ Stuttgart, Inst Signal Proc & Syst Theory, Stuttgart, Germany
[2] Univ Tubingen, Dept Radiol, Tubingen, Germany
[3] Univ Tubingen, Sect Expt Radiol, Tubingen, Germany
[4] Chinese Univ Hong Kong, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
[5] Univ Bretagne, INSERM, U1101, LaTIM, Brest, France
关键词
PET/MR motion correction; Respiratory and cardiac motion correction; Image registration; Gadgetron; RECONSTRUCTION; TIME; NAVIGATOR; PET/MRI; HEART; LIVER; REGISTRATION; COMBINATION; MOVEMENTS; SEQUENCE;
D O I
10.1016/j.media.2017.08.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: To develop a motion correction for Positron-Emission-Tomography (PET) using simultaneously acquired magnetic-resonance (MR) images within 90 s. Methods: A 90 s MR acquisition allows the generation of a cardiac and respiratory motion model of the body trunk. Thereafter, further diagnostic MR sequences can be recorded during the PET examination without any limitation. To provide full PET scan time coverage, a sensor fusion approach maps external motion signals (respiratory belt, ECG-derived respiration signal) to a complete surrogate signal on which the retrospective data binning is performed. A joint Compressed Sensing reconstruction and motion estimation of the subsampled data provides motion-resolved MR images (respiratory + cardiac). A 1-POINT DIXON method is applied to these MR images to derive a motion-resolved attenuation map. The motion model and the attenuation map are fed to the Customizable and Advanced Software for Tomographic Reconstruction (CASToR) PET reconstruction system in which the motion correction is incorporated. All reconstruction steps are performed online on the scanner via Gadgetron to provide a clinically feasible setup for improved general applicability. The method was evaluated on 36 patients with suspected liver or lung metastasis in terms of lesion quantification (SUVmax, SNR, contrast), delineation (FWHM, slope steepness) and diagnostic confidence level (3-point Likert-scale). Results: A motion correction could be conducted for all patients, however, only in 30 patients moving lesions could be observed. For the examined 134 malignant lesions, an average improvement in lesion quantification of 22%, delineation of 64% and diagnostic confidence level of 23% was achieved. Conclusion: The proposed method provides a clinically feasible setup for respiratory and cardiac motion correction of PET data by simultaneous short-term MRI. The acquisition sequence and all reconstruction steps are publicly available to foster multi-center studies and various motion correction scenarios. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 144
页数:16
相关论文
共 50 条
  • [1] Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling
    Robson, Philip M.
    Trivieri, MariaGiovanna
    Karakatsanis, Nicolas A.
    Padilla, Maria
    Abgral, Ronan
    Dweck, Marc R.
    Kovacic, Jason C.
    Fayad, Zahi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (22):
  • [2] MR-based correction of respiratory motion in oncological PET imaging using an integrated PET/MR system
    Wuerslin, Christian
    Schmidt, Holger
    Schwenzer, Nina
    Martirosian, Petros
    Claussen, Claus
    Stegger, Lars
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [3] MR-based motion correction for cardiac PET parametric imaging: a simulation study
    Rong Guo
    Yoann Petibon
    Yixin Ma
    Georges El Fakhri
    Kui Ying
    Jinsong Ouyang
    EJNMMI Physics, 5
  • [4] MR-based motion correction for cardiac PET parametric imaging: a simulation study
    Guo, Rong
    Petibon, Yoann
    Ma, Yixin
    El Fakhri, Georges
    Ying, Kui
    Ouyang, Jinsong
    EJNMMI PHYSICS, 2018, 5
  • [5] MR-Based Cardiac and Respiratory Motion-Compensation Techniques for PET-MR Imaging
    Munoz, Camila
    Kolbitsch, Christoph
    Reader, Andrew J.
    Marsden, Paul
    Schaeffter, Tobias
    Prieto, Claudia
    PET CLINICS, 2016, 11 (02) : 179 - 191
  • [6] MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging
    Petibon, Y.
    Sun, T.
    Han, P. K.
    Ma, C.
    El Fakhri, G.
    Ouyang, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19):
  • [7] Respiratory-resolved MR-based attenuation correction for motion-compensated cardiac PET-MR
    Kolbitsch, Christoph
    Neji, Radhouene
    Fenchel, Matthias
    Mallia, Andrew
    Marsden, Paul
    Schaeffter, Tobias
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (13):
  • [8] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [9] Accelerated MR-Based Motion Field Measurement for PET Motion Correction in PET/MR
    Han, Paul
    Djebra, Yanis
    Petibon, Yoann
    Marin, Thibault
    Ouyang, Jinsong
    El Fakhri, Georges
    Ma, Chao
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [10] Respiratory and cardiac motion correction in dual gated PET/MR imaging
    Hadi Fayad
    Florian Monnier
    Freedy Odille
    Jacques Felblinger
    Frederic Lamare
    Dimitris Visvikis
    EJNMMI Physics, 2 (Suppl 1)