Patient-Specific Radiation Dose and Cancer Risk Estimation in Pediatric Chest CT: A Study in 30 Patients

被引:0
|
作者
Lia, Xiang [1 ,2 ,3 ]
Samei, Ehsan [1 ,2 ,3 ,4 ,5 ]
Segars, W. Paul [1 ,2 ,3 ]
Sturgeon, Gregory M. [2 ,3 ]
Colsher, James G. [1 ,3 ]
Frush, Donald P. [1 ,3 ]
机构
[1] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[2] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[3] Duke Univ, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Dept Phys, Durham, NC 27705 USA
[5] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
关键词
com puted t omography; C T; chest; pediatric; or gan dose; effective dose; cancer risk; effective risk; patient-specific; Monte Carlo; ORGAN;
D O I
10.1117/12.845491
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Radiation-dose awareness and optimization in CT can greatly benefit from a dose-reporting system that provides radiation dose and cancer risk estimates specific to each patient and each CT examination. Recently, we reported a method for estimating patient-specific dose from pediatric chest CT. The purpose of this study is to extend that effort to patient-specific risk estimation and to a population of pediatric CT patients. Our study included thirty pediatric CT patients (16 males and 14 females; 0-16 years old), for whom full-body computer models were recently created based on the patients' clinical CT data. Using a validated Monte Carlo program, organ dose received by the thirty patients from a chest scan protocol (LightSpeed VCT, 120 kVp, 1.375 pitch, 40-mm collimation, pediatric body scan field-of-view) was simulated and used to estimate patient-specific effective dose. Risks of cancer incidence were calculated for radiosensitive organs using gender-, age-, and tissue-specific risk coefficients and were used to derive patientspecific effective risk. The thirty patients had normalized effective dose of 3.7-10.4 mSv/100 mAs and normalized effective risk of 0.5-5.8 cases/1000 exposed persons/100 mAs. Normalized lung dose and risk of lung cancer correlated strongly with average chest diameter (correlation coefficient: r = -0.98 to -0.99). Normalized effective risk also correlated strongly with average chest diameter (r = -0.97 to -0.98). These strong correlations can be used to estimate patient-specific dose and risk prior to or after an imaging study to potentially guide healthcare providers in justifying CT examinations and to guide individualized protocol design and optimization.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Size specific dose estimation in pediatric CT: preliminary study and conversion factors
    Zhang, Jian
    Zhang, Xiaojun
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (07) : 677 - 686
  • [42] Real-Time Patient-Specific CT Dose Estimation using a Deep Convolutional Neural Network
    Maier, Joscha
    Eulig, Elias
    Dorn, Sabrina
    Sawall, Stefan
    Kachelriess, Marc
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [43] ESTIMATION OF FEMALE RADIATION DOSES AND BREAST CANCER RISK FROM CHEST CT EXAMINATIONS
    Lahham, Adnan
    Masri, Hussein A. L.
    Kameel, Saleh
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (04) : 303 - 309
  • [44] A Patient-Specific 4D Digital Phantom for Dynamic Dose Estimation of External Ionizing Radiation
    Deng, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3693 - 3693
  • [45] Size-specific dose estimates in chest, abdomen, and pelvis CT examinations of pediatric patients
    Ozsoykal, Ismail
    Yurt, Aysegul
    Akgungor, Kadir
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2018, 24 (04): : 243 - 248
  • [46] Evolved size-specific dose estimates for patient-specific organ doses from chest CT scans based on hybrid patient size vectors
    Shao, Wencheng
    Yang, Ke
    Lou, Lizhi
    Lin, Xin
    Qu, Liangyong
    Zhuo, Weihai
    Liu, Haikuan
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2025,
  • [47] PATIENT-SPECIFIC ORGAN DOSES FROM PEDIATRIC HEAD CT EXAMINATIONS
    Garzon, W. J.
    Aldana, D. F. A.
    Cassola, V. F.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (01) : 1 - 8
  • [48] A pilot study of patient-specific cardiovascular MDCT dose maps and their utility in estimating patient-specific organ and effective doses in obese patients
    Thompson, Carla M.
    Yanof, Jeffrey H.
    Wiegert, Jens
    Bullen, Jennifer
    Obuchowski, Nancy
    Yaddanapudi, Kavitha
    Halliburton, Sandra S.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (03) : 265 - 268
  • [49] Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT
    Gao, Yiming
    Mahmood, Usman
    Liu, Tianyu
    Quinn, Brian
    Gollub, Marc J.
    Xu, X. George
    Dauer, Lawrence T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (04) : 738 - 746
  • [50] Patient-Specific Estimates of Absorbed and Effective Dose in Pediatric 18FDG PET/CT Imaging Studies
    Nosrati, R.
    Kofler, C.
    Sexton-stallone, B.
    MacDougall, R.
    Bolch, W.
    Fahey, F.
    MEDICAL PHYSICS, 2021, 48 (06)