Open source deformable image registration system for treatment planning and recurrence CT scans

被引:0
|
作者
Zukauskaite, Ruta [1 ,2 ]
Brink, Carsten [1 ,3 ]
Hansen, Christian Ronn [3 ,4 ]
Bertelsen, Anders [3 ,4 ]
Johansen, Jorgen [2 ]
Grau, Cai [5 ]
Eriksen, Jesper Grau [2 ]
机构
[1] Univ Southern Denmark, Inst Clin Res, Odense, Denmark
[2] Odense Univ Hosp, Dept Oncol, Sdr Blvd 29, DK-5000 Odense C, Denmark
[3] Odense Univ Hosp, Lab Radiat Phys, Odense, Denmark
[4] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW, Australia
[5] Aarhus Univ Hosp, Dept Oncol, Aarhus, Denmark
关键词
Computed tomography; Validation; elastix; head and neck; ADAPTIVE RADIATION-THERAPY; CONE-BEAM CT; NECK-CANCER; HEAD; VALIDATION; RADIOTHERAPY;
D O I
10.1007/s00066-016-0998-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Clinical application of deformable registration (DIR) of medical images remains limited due to sparse validation of DIR methods in specific situations, e. g. in case of cancer recurrences. In this study the accuracy of DIR for registration of planning CT (pCT) and recurrence CT (rCT) images of head and neck squamous cell carcinoma (HNSCC) patients was evaluated. Twenty patients treated with definitive IMRT for HNSCC in 2010-2012 were included. For each patient, a pCT and an rCT scan were used. Median interval between the scans was 8.5 months. One observer manually contoured eight anatomical regions-of-interest (ROI) twice on pCT and once on rCT. pCT and rCT images were deformably registered using the open source software elastix. Mean surface distance (MSD) and Dice similarity coefficient (DSC) between contours were used for validation of DIR. A measure for delineation uncertainty was estimated by assessing MSD from the re-delineations of the same ROI on pCT. DIR and manual contouring uncertainties were correlated with tissue volume and rigidity. MSD varied 1-3 mm for different ROIs for DIR and 1-1.5 mm for re-delineated ROIs performed on pCT. DSC for DIR varied between 0.58 and 0.79 for soft tissues and was 0.79 or higher for bony structures, and correlated with the volumes of ROIs (r = 0.5, p < 0.001) and tissue rigidity (r = 0.54, p < 0.001). DIR using elastix in HNSCC on planning and recurrence CT scans is feasible; an uncertainty of the method is close to the voxel size length of the planning CT images.
引用
收藏
页码:545 / 551
页数:7
相关论文
共 50 条
  • [21] Incorporating the synthetic CT image for improving the performance of deformable image registration between planning CT and cone-beam CT
    Li, Na
    Zhou, Xuanru
    Chen, Shupeng
    Dai, Jingjing
    Wang, Tangsheng
    Zhang, Chulong
    He, Wenfeng
    Xie, Yaoqin
    Liang, Xiaokun
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [22] Deformable registration of abdominal kilovoltage treatment planning CT and tomotherapy daily megavoltage CT for treatment adaptation
    Yang, Deshan
    Chaudhari, Summer R.
    Goddu, S. Murty
    Pratt, David
    Khullar, Divya
    Deasy, Joseph O.
    El Naqa, Issam
    MEDICAL PHYSICS, 2009, 36 (02) : 329 - 338
  • [23] Deformable image registration for contour propagation from CT to cone-beam CT scans in radiotherapy of prostate cancer
    Thor, Maria
    Petersen, Jorgen B. B.
    Bentzen, Lise
    Hoyer, Morten
    Muren, Ludvig Paul
    ACTA ONCOLOGICA, 2011, 50 (06) : 918 - 925
  • [24] Validation of biomechanical deformable image registration in the abdomen, thorax, and pelvis in a commercial radiotherapy treatment planning system
    Velec, Michael
    Moseley, Joanne L.
    Svensson, Stina
    Hardemark, Bjorn
    Jaffray, David A.
    Brock, Kristy K.
    MEDICAL PHYSICS, 2017, 44 (07) : 3407 - 3417
  • [25] Towards adaptive Tomotherapy: planning CT to MVCT deformable image registration for dose calculation
    Branchini, M.
    Broggi, S.
    Belli, M. L.
    Fiorino, C.
    Cattaneo, G. M.
    Perna, L.
    Calandrino, R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S851 - S852
  • [26] Improving Image Quality in 4D-CT Scans Using Deformable Registration and Selective Averaging
    Aliotta, E.
    Thomas, D.
    Gaudio, S.
    White, B.
    Jani, S.
    Lee, P.
    Lamb, J.
    Low, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] 4DCT treatment planning tools using deformable image registration
    Samant, S. S.
    Xia, J.
    Huang, M.
    Olivier, K. R.
    Chung, H.
    Liu, C.
    Chen, Y.
    Palta, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S42 - S42
  • [28] Deformable planning CT to cone-beam CT image registration in head-and-neck cancer
    Hou, Jidong
    Guerrero, Mariana
    Chen, Wenjuan
    D'Souza, Warren D.
    MEDICAL PHYSICS, 2011, 38 (04) : 2088 - 2094
  • [29] Deformable image registration for the use of magnetic resonance spectroscopy in prostate treatment planning
    Wu, XG
    Dibiase, SJ
    Gullapalli, R
    Yu, CX
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (05): : 1577 - 1583
  • [30] Deformable dose registration and treatment planning approaches
    Olivera, G
    Lu, W
    Kapatoes, J
    Ruchala, K
    Jeraj, R
    Reckwerdt, P
    Mackie, T
    MEDICAL PHYSICS, 2003, 30 (06) : 1365 - 1365