Paper-based microchip electrophoresis for point-of-care hemoglobin testing

被引:39
|
作者
Hasan, Muhammad Noman [1 ]
Fraiwan, Arwa [1 ]
An, Ran [1 ]
Alapan, Yunus [1 ,2 ]
Ung, Ryan [1 ]
Akkus, Asya [1 ]
Xu, Julia Z. [3 ]
Rezac, Amy J. [4 ]
Kocmich, Nicholas J. [4 ]
Creary, Melissa S. [5 ]
Oginni, Tolulope [6 ]
Olanipekun, Grace Mfon [7 ]
Hassan-Hanga, Fatimah [8 ]
Jibir, Binta W. [9 ]
Gambo, Safiya [10 ]
Verma, Anil K. [11 ]
Bharti, Praveen K. [11 ]
Riolueang, Suchada [12 ]
Ngimhung, Takdanai [12 ]
Suksangpleng, Thidarat [12 ]
Thota, Priyaleela [13 ]
Werner, Greg [14 ]
Shanmugam, Rajasubramaniam [11 ]
Das, Aparup [11 ]
Viprakasit, Vip [15 ]
Piccone, Connie M. [16 ,17 ]
Little, Jane A. [18 ,19 ,20 ]
Obaro, Stephen K. [4 ,7 ]
Gurkan, Umut A. [1 ,21 ]
机构
[1] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Case Biomfg & Microfabricat Lab, Cleveland, OH 44106 USA
[2] Max Planck Inst Intelligent Syst, Phys Intelligence Dept, D-70569 Stuttgart, Germany
[3] Duke Univ, Med Ctr, Dept Med, Durham, NC 27707 USA
[4] Univ Nebraska Med Ctr, Coll Med, Div Pediat Infect Dis, Omaha, NE 68198 USA
[5] Univ Michigan, Sch Publ Hlth, Dept Hlth Management & Policy, Ann Arbor, MI 48109 USA
[6] eHealth Africa, Kano, Nigeria
[7] Int Fdn Infect Dis Nigeria, Abuja, Nigeria
[8] Bayero Univ, Aminu Kano Teaching Hosp, Kano, Nigeria
[9] Hasiya Bayero Pediat Hosp, Kano, Nigeria
[10] Murtala Muhammad Specialist Hosp, Kano, Nigeria
[11] ICMR Natl Inst Res Tribal Hlth, Nagpur Rd, Jabalpur 482003, Madhya Pradesh, India
[12] Mahidol Univ, Siriraj Hosp, Fac Med, Siriraj Thalassemia Ctr, Bangkok 10700, Thailand
[13] Hemex Hlth Inc, Portland, OR 97239 USA
[14] Thogus Prod, Avon Lake, OH USA
[15] Mahidol Univ, Siriraj Hosp, Fac Med, Div Haematol Oncol,Dept Pediat, Bangkok, Thailand
[16] Rainbow Babies & Children Hosp, Univ Hosp, Cleveland, OH 44106 USA
[17] Case Western Reserve Univ, Sch Med, Dept Pediat, Cleveland, OH 44106 USA
[18] Cleveland Med Ctr, Univ Hosp, Cleveland, OH 44106 USA
[19] Case Western Reserve Univ, Sch Med, Dept Hematol & Oncol, Cleveland, OH 44106 USA
[20] Univ N Carolina, Sch Med, Div Hematol & Oncol, Chapel Hill, NC 27516 USA
[21] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
SICKLE-CELL-DISEASE; LIQUID-CHROMATOGRAPHY; GLOBAL BURDEN; ANEMIA; HYDROXYUREA; POLYMERIZATION; DEFORMABILITY; PREVALENCE; DISORDERS; TRIAL;
D O I
10.1039/c9an02250c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nearly 7% of the world's population live with a hemoglobin variant. Hemoglobins S, C, and E are the most common and significant hemoglobin variants worldwide. Sickle cell disease, caused by hemoglobin S, is highly prevalent in sub-Saharan Africa and in tribal populations of Central India. Hemoglobin C is common in West Africa, and hemoglobin E is common in Southeast Asia. Screening for significant hemoglobin disorders is not currently feasible in many low-income countries with the high disease burden. Lack of early diagnosis leads to preventable high morbidity and mortality in children born with hemoglobin variants in low-resource settings. Here, we describe HemeChip, the first miniaturized, paperbased, microchip electrophoresis platform for identifying the most common hemoglobin variants easily and affordably at the point-of-care in low-resource settings. HemeChip test works with a drop of blood. HemeChip system guides the user step-by-step through the test procedure with animated on-screen instructions. Hemoglobin identification and quantification is automatically performed, and hemoglobin types and percentages are displayed in an easily understandable, objective way. We show the feasibility and high accuracy of HemeChip via testing 768 subjects by clinical sites in the United States, Central India, sub-Saharan Africa, and Southeast Asia. Validation studies include hemoglobin E testing in Bangkok, Thailand, and hemoglobin S testing in Chhattisgarh, India, and in Kano, Nigeria, where the sickle cell disease burden is the highest in the world. Tests were performed by local users, including healthcare workers and clinical laboratory personnel. Study design, methods, and results are presented according to the Standards for Reporting Diagnostic Accuracy (STARD). HemeChip correctly identified all subjects with hemoglobin S, C, and E variants with 100% sensitivity, and displayed an overall diagnostic accuracy of 98.4% in comparison to reference standard methods. HemeChip is a versatile, mass-producible microchip electrophoresis platform that addresses a major unmet need of decentralized hemoglobin analysis in resource-limited settings.
引用
收藏
页码:2525 / 2542
页数:18
相关论文
共 50 条
  • [31] Paper-based microfluidic point-of-care diagnostic devices
    Yetisen, Ali Kemal
    Akram, Muhammad Safwan
    Lowe, Christopher R.
    LAB ON A CHIP, 2013, 13 (12) : 2210 - 2251
  • [32] Comparison of paper-based nucleic acid extraction materials for point-of-care testing applications
    Tang, Ruihua
    Li, Min
    Yan, Xueyan
    Xie, Mingyue
    Liu, Li Na
    Li, Zedong
    Xu, Feng
    CELLULOSE, 2022, 29 (04) : 2479 - 2495
  • [33] Paper-Based Fluidic Sensing Platforms for β-Adrenergic Agonist Residue Point-of-Care Testing
    Luo, Hongzhi
    Liu, Shan
    Shi, Lina
    Li, Zhu
    Bai, Qianwen
    Du, Xiaoxin
    Wang, Lijun
    Zha, He
    Li, Chenzhong
    BIOSENSORS-BASEL, 2022, 12 (07):
  • [34] A paper-based photoelectrochemical immunoassay for low-cost and multiplexed point-of-care testing
    Wang, Panpan
    Ge, Lei
    Ge, Shenguang
    Yu, Jinghua
    Yan, Mei
    Huang, Jiadong
    CHEMICAL COMMUNICATIONS, 2013, 49 (32) : 3294 - 3296
  • [35] Advances and challenges of fully integrated paper-based point-of-care nucleic acid testing
    Choi, Jane Ru
    Yong, Kar Wey
    Tang, Ruihua
    Gong, Yan
    Wen, Ting
    Li, Fei
    Pingguan-Murphy, Belinda
    Bai, Dan
    Xu, Feng
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 93 : 37 - 50
  • [36] Self-Powered, Paper-Based Electrochemical Devices for Sensitive Point-of-Care Testing
    Pal, Aniket
    Cuellar, Hugo E.
    Kuang, Randy
    Caurin, Heloisa F. N.
    Goswami, Debkalpa
    Martinez, Ramses V.
    ADVANCED MATERIALS TECHNOLOGIES, 2017, 2 (10):
  • [37] Comparison of paper-based nucleic acid extraction materials for point-of-care testing applications
    Ruihua Tang
    Min Li
    Xueyan Yan
    Mingyue Xie
    Li Na Liu
    Zedong Li
    Feng Xu
    Cellulose, 2022, 29 : 2479 - 2495
  • [38] A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample
    Devi, A. Lakshmi
    Resmi, P. E.
    Pradeep, Aarathi
    Suneesh, P. V.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 287
  • [39] Magnetic Bead Handling Using a Paper-Based Device for Quantitative Point-of-Care Testing
    Arias-Alpizar, Kevin
    Sanchez-Cano, Ana
    Prat-Trunas, Judit
    Sulleiro, Elena
    Bosch-Nicolau, Pau
    Salvador, Fernando
    Oliveira, Ines
    Molina, Israel
    Sanchez-Montalva, Adrian
    Baldrich, Eva
    BIOSENSORS-BASEL, 2022, 12 (09):
  • [40] Direct writing electrodes using a ball pen for paper-based point-of-care testing
    Li, Zedong
    Li, Fei
    Hu, Jie
    Wee, Wei Hong
    Han, Yu Long
    Pingguan-Murphy, Belinda
    Lu, Tian Jian
    Xu, Feng
    ANALYST, 2015, 140 (16) : 5526 - 5535