The value of the white precursor cell channel (WPC) on the Sysmex XN-1000 analyser in a specialist paediatric hospital

被引:20
|
作者
Jones, Amanda S. [1 ]
Tailor, Hitesh [2 ]
Liesner, Ri [1 ]
Machin, Samuel J. [2 ]
Briggs, Carol J. [2 ]
机构
[1] NHS Fdn Trust, Great Ormond St Hosp Children, Camelia Botnar Labs, Dept Haematol, London, England
[2] Univ Coll London Hosp, Dept Haematol, London, England
关键词
PAEDIATRIC HAEMATOLOGY; NEO-NATAL HAEMATOLOG; ANALYTICAL METHODS; PERFORMANCE EVALUATION; BLOOD; LYMPHOCYTES; MORPHOLOGY;
D O I
10.1136/jclinpath-2014-202640
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Background Historically, haematology analyser flags for abnormal white blood cells (WBCs) show good sensitivity but lower specificity, causing unnecessary blood film reviews. While the WBC differential channel on Sysmex XE and XN instruments reports a combined flag for blasts/abnormal lymphocytes, the new white precursor cell channel (WPC) on the XN series has been introduced to separate this into a specific flag for either cell type or, if no abnormality, remove the flag entirely. Aims To compare the efficiency of abnormal WBC flags from the XN WPC to our existing analyser and determine whether WPC can reduce false positive flags and blood films required. Methods Abnormal WBC flags from the Sysmex XE-5000 and XN-1000 were compared to manual differential and blood film morphology on 300 K(2)EDTA samples from infants and children. Results The XN WPC flag for blasts was more sensitive and specific than flags indicating blasts on the XE-5000, with a reduction in false positives from 64% (XE) to 36% (XN). Overall efficiency of the WPC flag for abnormal lymphocytes was 94% vs 79% on the XE. WPC reduced false positive flags for blasts and abnormal lymphocytes on neonatal samples by 50%. Automatic reflex analysis by WPC correctly removed a false positive flag from the white cell differential channel on 46% of samples. Total abnormal WBC flags from XN WPC were less (73) than the XE-5000 (92). Conclusions XN WPC demonstrated superior efficiency of abnormal WBC flags on paediatric samples, compared to the XE-5000, with greater sensitivity and specificity of flagging, reducing blood films for review.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 22 条
  • [1] BLOOD CELLS ANALYSIS IN CEREBROSPINAL FLUID USING SYSMEX® XN-1000 HEMATOLOGY ANALYSER
    Alic, Elizabeta Boznar
    Kase, Simona
    Skitek, Milan
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 : 81 - 81
  • [2] SYSMEX XN WHITE PRECURSOR CHANNEL EVALUATION
    Kosasih, Agus
    Setiawan, Lyana
    Hayuanta, Hubertus
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 93 - 93
  • [3] The value of extended inflammatory parameters obtained on Sysmex XN-1000 haematology analyser as early laboratory indicators of COVID-19
    Lapic, Ivana
    Brencic, Tina
    Rogic, Dunja
    Pozaic, Petra
    Juricic, Gordana
    Honovic, Lorena
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2022, 82 (03): : 257 - 259
  • [4] Cell counting chamber vs. Sysmex XN-1000 for determining white blood cell count and differentiation for body fluids
    Evren, Ebru
    Us, Ebru
    Hekimoglu, Can Huseyin
    Karahan, Zeynep Ceren
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2023, 48 (01): : 19 - 25
  • [5] Performance evaluation of the Sysmex XN-1000 hematology analyzer in assessment of the white blood cell count differential in pediatric specimens
    Becker, P. -H.
    Fenneteau, O.
    Da Costa, L.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 (01) : 54 - 63
  • [6] Evaluation of activated lymphocytes (RE-LYMP, AS-LYMP) on hematological analyser sysmex XN-1000 with manual method
    Kajinic, D.
    Grdisa, K.
    CLINICA CHIMICA ACTA, 2022, 530 : S175 - S175
  • [7] SCREENING OF DYSPLASTIC NEUTROPHILS USING CELL POPULATION DATA USING SYSMEX XN-1000 ANALYZER
    Kim, Hyunjung
    Han, Eunhee
    Han, Kyungja
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 69 - 69
  • [8] Performance evaluation of the white cell precursor channel on the Sysmex XN hematology analyzer in HIV specimens
    Schapkaitz, Elise
    Khoza, Phoyisile
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (04)
  • [9] SYSTEMIC IMMUNE INFLAMMATION INDEX & SYSMEX XN-1000 RESEARCH WHITE BLOOD CELL PARAMETERS IN COVID-19 PATIENTS
    Petridou, Eleni
    Agorasti, Athanasia
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 134 - 135
  • [10] PERFORMANCE EVALUATION OF THE WHITE CELL PRECURSOR CHANNEL ON THE SYSMEX XN-9000 HEMATOLOGY ANALYZER
    Schapkaitz, Elise
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 128 - 128