Influence of Screw Design, Sex, and Approach in Scaphoid Fracture Fixation

被引:15
|
作者
Meermans, Geert [1 ]
Verstreken, Frederik [2 ]
机构
[1] Lievensberg Hosp, Bergen Op Zoom, Netherlands
[2] Monica Hosp, Deurne, Belgium
关键词
HERBERT SCREW; CAST IMMOBILIZATION; INTERNAL-FIXATION; WAIST FRACTURES; DORSAL APPROACH; PLACEMENT; EPIDEMIOLOGY; AGREEMENT; INSERTION; NONUNION;
D O I
10.1007/s11999-011-2218-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Screw fixation of scaphoid fractures has gained popularity. A long central screw has been shown to be biomechanically advantageous. We compared the ability of different screw designs to obtain this goal and determined the influence of sex and approach on screw length. We performed all measurements on three-dimensional reconstructions of 20 CT scans of normal scaphoids (10 men and 10 women) with the use of software. The three-dimensional computer models were analyzed, the central axis was defined, and the screws were placed along this axis. We compared 15 different available screw designs and volar and dorsal screw placement. The length of the scaphoid along its central axis was longer in men (mean, 27.14 mm; standard error of the mean, 0.97 mm) than in women (mean, 23.86 mm; standard error of the mean, 0.37 mm). The screw length that can be used was longer in the volar approach (mean, 23.72 mm; standard error of the mean, 0.19 mm) than in the dorsal approach (mean, 23.31 mm; standard error of the mean, 0.19 mm) regardless of the screw design. Screws with a trailing thread diameter greater than 3.9 mm and leading thread diameter greater than 3.0 mm were shorter. Scaphoids in women are smaller than in men. Theoretically, fixation of scaphoid fractures through a volar approach will allow the surgeon to use longer screws. The screw design has a significant influence on the screw length that can be used in scaphoid fracture fixation. We recommend using a differential pitch screw with a thread diameter of 3.9 mm or less.
引用
收藏
页码:1673 / 1681
页数:9
相关论文
共 50 条
  • [31] Trans-scaphoid perilunate fracture dislocations: results of screw fixation of the scaphoid and lunotriquetral repair with a dorsal approach (vol 30A, pg 1145, 2005)
    Knoll, VD
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (02): : 328 - 328
  • [32] Bone Marrow Aspirate Injection Technique in the Treatment of Scaphoid Fracture Utilizing Percutaneous Screw Fixation
    Hasan, Rebwar A.
    Barawi, Omer A.
    Hasan, Jalal A.
    MEDICINA BALEAR, 2024, 39 (01): : 155 - 162
  • [33] Percutaneous Screw Fixation of Scaphoid Waist Fracture Non-Union Without Bone Grafting
    Hegazy, Galal
    JOURNAL OF HAND AND MICROSURGERY, 2015, 7 (02) : 250 - 255
  • [34] Percutaneous Fixation of Recent Scaphoid Fracture
    El Morshidy, Ahmed F.
    Abdelgaid, Sherif M.
    KUWAIT MEDICAL JOURNAL, 2012, 44 (03): : 219 - 223
  • [35] Early results of a new implant: 3.0 mm headless compression screw for scaphoid fracture fixation
    Singisetti, K.
    Aldlyami, E.
    Middleton, A.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (07) : 690 - 693
  • [36] Periprosthetic fracture of the scaphoid after successful headless compression screw fixation: report of two cases
    Liu, Edward H.
    Schulz, Philip D.
    Ek, Eugene T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (10) : 1093 - 1095
  • [37] A Comparison Between Robotic-Assisted Scaphoid Screw Fixation and a Freehand Technique for Acute Scaphoid Fracture: A Randomized, Controlled Trial
    Guo, Yang
    Ma, Wei
    Zlotolow, Dan
    Wang, Chao
    Tong, Dedi
    Liu, Kun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (12): : 1172 - 1179
  • [38] Internal fixation with Kirschner wires is as efficient as rigid screw fixation in scaphoid fracture: long-term functional outcome
    Jiang, Ziping
    Cui, Jianli
    Gong, Xu
    Lu, Laijin
    ACTA ORTHOPAEDICA BELGICA, 2018, 84 (01): : 99 - 104
  • [39] Persistent Fracture Line After Scaphoid Fracture Fixation
    Lutsky, Kevin
    Matzon, Jonas L.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (11): : 2294 - 2296
  • [40] INTERNAL-FIXATION OF SCAPHOID INJURIES USING THE HERBERT SCREW THROUGH A DORSAL APPROACH
    DOSREIS, FB
    KOEBERLE, G
    LEITE, NM
    KATCHBURIAN, MV
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (05): : 792 - 797