Thermal Study of DCNQI-Cu using a High Accuracy Specific Heat Measurement System

被引:3
|
作者
Matsui, Ayaka [1 ]
Takaoka, Yui [1 ]
Nishio, Yutaka [1 ]
Kato, Reizo [2 ]
Kajita, Koji [1 ]
机构
[1] Toho Univ, Dept Phys, Miyama 2-2-1, Chiba 2748510, Japan
[2] RIKEN, Condensed Mol Mat Lab, Wako, Saitama 3510198, Japan
基金
日本学术振兴会;
关键词
D O I
10.1088/1742-6596/150/4/042120
中图分类号
O414.1 [热力学];
学科分类号
摘要
DCNQI-Cu system exhibits a mysterious metal-insulator-metal (M-I-M) phase transition. Deuteration of methyl basis can control critical temperatures of these peculiar phase transitions. We have been studying a mechanism of the transitions by measuring thermal properties. To quantitatively discuss the phase transitions, we have developed specific heat measurement system in a wide temperature range between 5 K and 200 K for the sample with the weight of less than 0.3mg. We have succeeded in an observation of the specific heat jump and latent heat at this first order phase transition in the cooling and heating processes.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Thermal study of antiferromagnetic ordering in deuterated (DMe-DCNQI)(2)Cu
    Nishio, Y
    Tega, T
    Tamura, M
    Kajita, K
    Aonuma, S
    Sawa, H
    Kato, R
    Kobayashi, H
    SYNTHETIC METALS, 1997, 85 (1-3) : 1739 - 1740
  • [22] Accuracy and reliability of thermal threshold measurement in the chin using heat flux technique
    Kawano, Teppei
    Kabasawa, Yuhji
    Ashikawa, Suga
    Sato, Yuriko
    Jinno, Shigeharu
    Omura, Ken
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (04): : 500 - 504
  • [23] A high accuracy ultrasonic measurement system using the prism technique
    Merdjana, Hassina
    Boukabou, Abdelkrim
    Grimes, Morad
    MEASUREMENT, 2018, 114 : 195 - 202
  • [24] Study on high accuracy temperature measurement technology of infrared thermal imager
    Zhang Z.
    Wang P.
    Yu X.
    Zhang J.
    Li T.
    1600, Science Press (41): : 10 - 18
  • [25] Specific heat measurement of high temperature thermal insulations by drop calorimeter method
    Ohmura, T
    Tsuboi, M
    Onodera, M
    Tomimura, T
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2003, 24 (02) : 559 - 575
  • [26] Specific Heat Measurement of High Temperature Thermal Insulations by Drop Calorimeter Method
    T. Ohmura
    M. Tsuboi
    M. Onodera
    T. Tomimura
    International Journal of Thermophysics, 2003, 24 : 559 - 575
  • [27] High precision measurement of specific heat using dual heating and cooling
    Tao S.
    Yang Z.
    Tian G.
    Zhang W.
    Yang, Zhengwei (yangzhengwei1136@163.com), 2017, Shanghai Jiaotong University (51): : 124 - 128
  • [28] A Reflection Measurement System With High Accuracy Using Binary Coded Signals
    Notzon, Gordon
    Storch, Robert
    Musch, Thomas
    Vogt, Michael
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (10) : 7825 - 7836
  • [29] Simultaneous Measurement of Thermal Conductivity, Thermal Diffusivity, and Specific Heat of Nanofluids
    Sohel Murshed, S. M.
    HEAT TRANSFER ENGINEERING, 2012, 33 (08) : 722 - 731
  • [30] Simultaneous measurement of thermal conductivity, thermal diffusivity, and volumetric specific heat
    Hammerschmidt, U.