Tension-band wiring of transverse fractures of patella. The effect of site of wire twists and orientation of stainless steel wire loop: a biomechanical investigation

被引:51
|
作者
John, J. [1 ]
Wagner, W. W.
Kuiper, J. H.
机构
[1] Robert Jones & Agnes Hunt Orthopaed Hosp, Oswestry SY10 7AQ, Shrops, England
[2] Robert Jones & Agnes Hunt Orthopaed Hosp, Clin Biomech, Oswestry SY10 7AQ, Shrops, England
关键词
D O I
10.1007/s00264-006-0238-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Tension-band wiring is commonly used to treat transverse patella fractures. The most common configuration has parallel Kirschner (K) wires and a stainless steel wire loop placed in a vertically oriented figure of eight. Early mobilisation is important but can cause detrimental displacement at the fracture site. A wooden model of a transversely fractured patella was used to compare different fixation constructs. The fracture was fixed using two K wires and a stainless steel wire loop. One or two wire twists were used, placed either arbitrarily or at corners of the loop. The loop was oriented either vertically or horizontally. Interfragmentary compression at the point of wire breakage and permanent displacement on cyclic loading was measured for each construct. Placement of the figure of eight in a horizontal orientation with two wire twists at the corner improved interfragmentary compression by 63% (p < 0.05, Tukey post hoc test). On cyclic loading, all constructs with vertical figure of eight but none with a horizontal construct failed (p=0.01; Fisher's exact test). Permanent fracture displacement after cyclic loading was 67% lower with horizontal figure of eight constructs (p < 0.05; t test). Placing wire twists at the corner and a horizontal placement of figure of eight improves stability of the construct.
引用
收藏
页码:703 / 707
页数:5
相关论文
共 27 条
  • [21] K-wire position in tension-band wiring technique affects stability of wires and long-term outcome in surgical treatment of olecranon fractures
    van der Linden, Sabine C.
    van Kampen, Albert
    Jaarsma, Ruurd L.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (03) : 405 - 411
  • [22] Treatment of displaced fractures of the patella: Tension band wiring technique with the one-end or both-ends K-wire bending fixation method
    Huang, Po-Hua
    Hsu, Chi-Hsiang
    Hsu, Shan-Ling
    Liu, Hao-Chen
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (01)
  • [23] A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study
    Han, Fucai
    Pearce, Christopher Jon
    Ng, David Q. K.
    Ramruttun, Amit K.
    Chong, Desmond Y. R.
    Murphy, Diarmuid
    Lim, Chin Tat
    Lee, Bernard C. S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (02): : 270 - 276
  • [24] Clinical results of treatment using a modified K-wire tension band versus a cannulated screw tension band in transverse patella fractures: A strobe-compliant retrospective observational study
    Tan, Honglue
    Dai, Pengyi
    Yuan, Yanhao
    MEDICINE, 2016, 95 (40)
  • [25] Letter to the Editor regarding "Treatment of displaced fractures of the patella: Tension band wiring technique with the one-end or both-ends K-wire bending fixation method"
    Sinha, Nirmal Kumar
    Bhardwaj, Amit
    Rao, Ashutosh Sadashiva
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (03)
  • [26] The Effect of Interface Orientation During Uniaxial Tension of Functionally Gradient Materials of a Stainless Steel-Copper System Formed by the Wire-Feed Electron Beam Additive Manufacturing
    K. S. Osipovich
    A. V. Chumaevskii
    E. N. Moskvichev
    E. A. Kolubaev
    Russian Physics Journal, 2023, 66 : 1039 - 1045
  • [27] The Effect of Interface Orientation During Uniaxial Tension of Functionally Gradient Materials of a Stainless Steel-Copper System Formed by the Wire-Feed Electron Beam Additive Manufacturing
    Osipovich, K. S.
    Chumaevskii, A. V.
    Moskvichev, E. N.
    Kolubaev, E. A.
    RUSSIAN PHYSICS JOURNAL, 2023, 66 (10) : 1039 - 1045