Outdoor synthetic temperature for the calculation of space heating load

被引:7
|
作者
Hong, TZ [1 ]
Jiang, Y [1 ]
机构
[1] Tsing Hua Univ, Dept Thermal Engn, HVAC Div, Beijing 100084, Peoples R China
关键词
heating load calculation; outdoor design conditions; residential buildings; stochastic analysis; thermal performance of buildings;
D O I
10.1016/S0378-7788(98)00013-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Methods to select the outdoor design temperature (ODT) for heating load calculation specified in current design codes in different countries are firstly discussed. Then a new method namely Stochastic Analysis is presented to determine the outdoor synthetic temperature (OST), which fully considers the randomness of weather and internal casual gains, and the thermal performance of buildings. The concept of OST enables the design of space heating system to be the trade-off between economics and risk. Finally, case studies of the influence of different building components on OST of a residential room in Beijing have been studied, which shows that OST depends upon building structures as well as weather conditions. It is recommended that OST rather than ODT should be employed in heating load calculation hence, sizing equipment for space heating systems. (C) 1998 Published by Elsevier Science S.A. All rights reserved.
引用
收藏
页码:269 / 277
页数:9
相关论文
共 50 条
  • [42] THE POTENTIAL FOR LOAD MANAGEMENT THROUGH THE APPLICATION OF PASSIVE SOLAR SPACE HEATING
    PFEIFFER, HG
    ROBERTS, PL
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 41 : 14 - 15
  • [43] Compensation of induction heating load edge-effect by space control
    Forzan, Michele
    Lupi, Sergio
    Toffano, Ezio
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2011, 30 (05) : 1558 - 1569
  • [44] An overview of simulation tools for predicting the mean radiant temperature in an outdoor space
    Naboni, Emanuele
    Meloni, Marco
    Coccolo, Silvia
    Kaempf, Jerome
    Scartezzini, Jean-Louis
    CISBAT 2017 INTERNATIONAL CONFERENCE FUTURE BUILDINGS & DISTRICTS - ENERGY EFFICIENCY FROM NANO TO URBAN SCALE, 2017, 122 : 1112 - 1117
  • [45] Minimum Load Shedding Calculation Based on Static Voltage Security Region in Load Injection Space
    Dong Zeyin
    Miao Weiwei
    Jia Hongjie
    2011 IEEE REGION 10 CONFERENCE TENCON 2011, 2011, : 959 - 963
  • [46] The research on relationship of load rate and outdoor temperature for air-cooled unit
    Gao, Liying
    Li, Rui
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 1210 - 1213
  • [47] The effect of temperature on airborne filamentous fungi in the indoor and outdoor space of a hospital
    Fariba Abbasi
    Mohammad Reza Samaei
    Environmental Science and Pollution Research, 2019, 26 : 16868 - 16876
  • [48] The effect of temperature on airborne filamentous fungi in the indoor and outdoor space of a hospital
    Abbasi, Fariba
    Samaei, Mohammad Reza
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (17) : 16868 - 16876
  • [49] Optimization of heating curves for heat pumps in operation: Outdoor temperature ranges for energy-efficient heating curve shifts
    Potthoff, Ugne
    Brudermueller, Tobias
    Hopf, Konstantin
    Wortmann, Felix
    APPLIED ENERGY, 2025, 389
  • [50] OUTDOOR AIR - CALCULATION AND DELIVERY
    WARDEN, D
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1995, 37 (06): : 54 - &