Fire safety case study of a railway tunnel: Smoke evacuation

被引:3
|
作者
Van Maele, Karim [1 ]
Merci, Bart [1 ]
机构
[1] Univ Ghent, Fac Engn, Dept Flow Heat & Combust Mech, B-9000 Ghent, Belgium
来源
THERMAL SCIENCE | 2007年 / 11卷 / 02期
关键词
tunnel fire safety; smoke control; simulation; fire dynamics simulator;
D O I
10.2289/TSCI0702207M
中图分类号
O414.1 [热力学];
学科分类号
摘要
When afire occurs in a tunnel, it is of great importance to assure the safety of the occupants of the tunnel. This is achieved by creating smoke-free spaces in the tunnel through control of the smoke gases. In this paper, results are presented of a study concerning the fire safety in a real scale railway tunnel test case. Numerical simulations are performed in order to examine the possibility of natural ventilation of smoke in inclined tunnels. Several aspects are taken into account: the length of the simulated tunnel section, the slope of the tunnel and the possible effects of external wind at one portal of the funnel. The Fire Dynamics Simulator of the National Institute of Standards and Technology, USA, is applied to perform the simulations. The simulations show that for the local behaviour of the smoke during the early stages of the fire, the slope of the tunnel is of little importance. Secondly, the results show that external wind and/or pressure conditions have a large effect on the smoke gases inside the tunnel. Finally, some idea for the value of the critical ventilation velocity is given. The study also shows that computational fluid dynamics calculations are a valuable tool for large scale, real life complex fire cases.
引用
收藏
页码:207 / 222
页数:16
相关论文
共 50 条
  • [11] VERIFICATION OF NUMERICAL MODEL OF FIRE AND SMOKE DEVELOPMENT IN RAILWAY TUNNEL
    Horova, Kamila
    Wald, Frantisek
    Apeltauer, Jiri
    APPLICATIONS OF STRUCTURAL FIRE ENGINEERING, 2017,
  • [12] Numerical Simulation for Smoke Flow of the Underground Railway Tunnel Fire
    Li, Lixin
    Zhao, Lanying
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 1454 - 1457
  • [13] Simulation of the Evacuation of People in a Road Tunnel in the Event of Fire - Case Study
    Schmidt-Polonczyk, Natalia
    Burtan, Zbigniew
    Liszka, Piotr
    ARCHIVES OF MINING SCIENCES, 2021, 66 (01) : 13 - 28
  • [14] Study On The Smoke Evacuation And Safety-evaluation Of Oversized Shield Machine In Tunnel Drilling
    Wang, Weimin
    ADVANCES IN STRUCTURAL ENGINEERING, PTS 1-3, 2011, 94-96 : 2226 - 2232
  • [15] A Study on the Evacuation of an Extra-Long Highway Tunnel Fire-A Case Study of Chengkai Tunnel
    Wang, Kai
    Hu, Jingwei
    Chen, Ruiding
    Wang, Jianhua
    SUSTAINABILITY, 2023, 15 (06)
  • [16] Smoke extraction experiments in case of fire in a tunnel
    Vauquelin, O
    Mégret, O
    FIRE SAFETY JOURNAL, 2002, 37 (05) : 525 - 533
  • [17] VERIFICATION AND VALIDATION OF A NUMERICAL MODEL OF FIRE AND SMOKE DEVELOPMENT IN A RAILWAY TUNNEL
    Cabova, Kamila
    Apeltauer, Jiri
    Wald, Frantisek
    ACTA POLYTECHNICA, 2016, 56 (06) : 432 - 439
  • [18] SIMULATION ANALYSIS OF SMOKE CHARACTERISTIC FOR TRAIN FIRE IN METROPOLIS RAILWAY TUNNEL
    Han, Xin
    Wu, Guan-Hai
    Cong, Bei-Hua
    Liu, Qing-Qing
    Hu, Zheng
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 1634 - 1638
  • [19] A Case Study of High Power Fire and Evacuation Process in an Urban Road Tunnel
    Krol, Aleksander
    Krol, Malgorzata
    MODERN TRAFFIC ENGINEERING IN THE SYSTEM APPROACH TO THE DEVELOPMENT OF TRAFFIC NETWORKS, 2020, 1083 : 202 - 215
  • [20] Experimental and numerical study on the smoke and velocity distribution in an extra-long railway tunnel fire
    Tao, Liangliang
    Yan, Xiaonan
    Zhang, Yimin
    Zeng, Yanhua
    Fang, Yong
    Bai, Yun
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 117 (117)