Dose volume assessment of high dose rate Ir-192 endobronchial implants

被引:4
|
作者
Saw, CB
Korb, LJ
Pawlicki, T
Wu, A
机构
[1] W VIRGINIA UNIV,ROBERT C BYRD HLTH SCI CTR,DIV RADIAT ONCOL,MORGANTOWN,WV 26506
[2] HAHNEMANN UNIV,PITTSBURGH,PA
[3] ALLEGHENY GEN HOSP,MED COLL PENN,DEPT RADIAT ONCOL,PITTSBURGH,PA 15212
关键词
radiation therapy; brachytherapy; dosimetry; treatment planning;
D O I
10.1016/0360-3016(95)02121-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR Ir-192 Source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated, Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume, Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints, The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points, The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant, This study supports the existence of a relationship between the dwell position spacing acid the distance from the catheter aids to the reference dose or dose constraint points, Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter aids to the reference dose or dose constraint points.
引用
收藏
页码:917 / 922
页数:6
相关论文
共 50 条
  • [1] A METHOD TO CHECK TREATMENT TIME CALCULATIONS IN IR-192 HIGH-DOSE-RATE VOLUME IMPLANTS
    VENSELAAR, JLM
    BIERHUIZEN, HWJ
    KLOP, R
    MEDICAL PHYSICS, 1995, 22 (09) : 1499 - 1500
  • [2] Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization
    Gay, H. A.
    Allison, R. R.
    Downie, G. H.
    Mota, H. C.
    Austerlitz, C.
    Jenkins, T.
    Sibata, C. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : 2987 - 2999
  • [3] CALCULATION OF DOSE DISTRIBUTIONS FOR IR-192 IMPLANTS
    WELSH, AD
    DIXONBROWN, A
    STEDEFORD, JBH
    ACTA RADIOLOGICA ONCOLOGY, 1983, 22 (04): : 331 - 336
  • [4] Transit dose of an Ir-192 high dose rate brachytherapy stepping source
    Wong, TPY
    Fernando, W
    Johnston, PN
    Bubb, IF
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 323 - 331
  • [5] A dosimetric study on the Ir-192 high dose rate Flexisource
    Granero, D.
    Perez-Calatayud, J.
    Casal, E.
    Ballester, F.
    Venselaar, J.
    MEDICAL PHYSICS, 2006, 33 (12) : 4578 - 4582
  • [6] DOSE HOMOGENEITY INDEX FOR IR-192 INTERSTITIAL IMPLANTS
    WU, A
    ULIN, K
    STERNICK, ES
    MEDICAL PHYSICS, 1986, 13 (05) : 784 - 784
  • [7] CALIBRATION OF IR-192 HIGH-DOSE-RATE AFTERLOADING SYSTEMS
    GOETSCH, SJ
    ATTIX, FH
    PEARSON, DW
    THOMADSEN, BR
    MEDICAL PHYSICS, 1991, 18 (03) : 462 - 467
  • [8] STATISTICAL EVALUATION OF A TOTAL DOSE-DOSE RATE RELATIONSHIP IN ORAL TONGUE CANCER IR-192 IMPLANTS
    FEROLDI, P
    FRATA, P
    BARONCELLI, G
    BELLETTI, S
    STRAHLENTHERAPIE UND ONKOLOGIE, 1986, 162 (09): : 561 - 564
  • [9] DOSE AND DOSE-RATE IN IR-192 INTERSTITIAL IRRADIATION FOR CARCINOMA OF TONGUE
    INOUE, T
    HORI, S
    MIYATA, Y
    IKEDA, H
    SHIGEMATSU, Y
    FUCHIHATA, H
    TANAKA, Y
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1978, 17 (01): : 27 - 32
  • [10] HIGH-DOSE IR-192 IMPLANTS FOR TREATMENT OF EARLY BREAST-CARCINOMA
    WINTER, PJ
    TONG, D
    MAYLES, HMO
    CHAUDERY, MA
    FENTIMAN, IS
    BRACHYTHERAPY 2, 1989, : 509 - 511