Experimental Validation of a Microwave System for Brain Stroke 3-D Imaging

被引:32
|
作者
Rodriguez-Duarte, David O. [1 ]
Vasquez, Jorge A. Tobon [1 ]
Scapaticci, Rosa [2 ]
Turvani, Giovanna [1 ]
Cavagnaro, Marta [3 ]
Casu, Mario R. [1 ]
Crocco, Lorenzo [2 ]
Vipiana, Francesca [1 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, I-10129 Turin, Italy
[2] Natl Res Council Italy, Inst Electromagnet Sensing Environm, I-80124 Naples, Italy
[3] Sapienza Univ Rome, Dept Informat Engn Elect & Telecommun, I-00184 Rome, Italy
关键词
microwave imaging; biomedical imaging; brain stroke monitoring; antenna array; hemorrhagic stroke; ischemic stroke; DIELECTRIC-PROPERTIES; PHANTOM; TIME;
D O I
10.3390/diagnostics11071232
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper experimentally validates the capability of a microwave prototype device to localize hemorrhages and ischemias within the brain as well as proposes an innovative calibration technique based on the measured data. In the reported experiments, a 3-D human-like head phantom is considered, where the brain is represented either with a homogeneous liquid mimicking brain dielectric properties or with ex vivo calf brains. The microwave imaging (MWI) system works at 1 GHz, and it is realized with a low-complexity architecture formed by an array of twenty-four printed monopole antennas. Each antenna is embedded into the "brick" of a semi-flexible dielectric matching medium, and it is positioned conformal to the head upper part. The imaging algorithm exploits a differential approach and provides 3-D images of the brain region. It employs the singular value decomposition of the discretized scattering operator obtained via accurate numerical models. The MWI system analysis shows promising reconstruction results and extends the device validation.
引用
收藏
页数:18
相关论文
共 50 条
  • [11] A Design of Geometry and Antennas Layout of 3D Microwave Imaging System for Brain Stroke Monitoring
    Tesarik, Jan
    Hrncir, Josef
    Pokorny, Tomas
    2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS-SPRING), 2019, : 3342 - 3347
  • [12] Field-Based Discretization of the 3-D Contrast Source Inversion Method Applied to Brain Stroke Microwave Imaging
    Mariano, Valeria
    Vasquez, Jorge A. Tobon
    Rodriguez-Duarte, David O.
    Vipiana, Francesca
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2024, 8 (03): : 290 - 297
  • [13] Experimental assessment of a 3-D plenoptic endoscopic imaging system
    Hanh N.D.Le
    Ryan Decker
    Axel Krieger
    Jin U.Kang
    Chinese Optics Letters, 2017, 15 (05) : 72 - 76
  • [14] Experimental assessment of a 3-D plenoptic endoscopic imaging system
    Le, Hanh N. D.
    Decker, Ryan
    Krieger, Axel
    Kang, Jin U.
    CHINESE OPTICS LETTERS, 2017, 15 (05)
  • [15] 3-D imaging system
    不详
    MATERIALS PERFORMANCE, 2002, 41 (09) : 12 - 13
  • [16] Microwave Imaging Device Prototype for Brain Stroke 3D Monitoring
    Vasquez, J. A. Tobon
    Rodriguez-Duarte, D. O.
    Origlia, C.
    Turvani, G.
    Scapaticci, R.
    Casu, M. R.
    Crocco, L.
    Vipiana, F.
    2022 INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY (IWAT), 2022, : 200 - 202
  • [17] 3-D Microwave Imaging for Breast Cancer
    Cheng, George
    Zhu, Yong
    Grzesik, Jan
    RADIOENGINEERING, 2012, 21 (04)
  • [18] 3-D Ghost Imaging with Microwave Radar
    Xu, Ran
    Li, Yachao
    Xing, Mengdao
    Shao, Peng
    2014 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS & TECHNIQUES (IST), 2014, : 190 - 194
  • [19] 3-d volume imaging and 3-D angiography of the fetal brain
    Pooh, RK
    Pooh, KH
    PERINATAL MEDICINE OF THE NEW MILLENNIUM, 2001, : 371 - 374
  • [20] Sparse 2-D arrays for 3-D phased array imaging - Experimental validation
    Austeng, A
    Holm, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1087 - 1093