RESPONSE TIME OF MAGNETORHEOLOGICAL (MR) FLUID AND MR VALVES UNDER VARIOUS FLOW CONDITIONS

被引:0
|
作者
Sahin, Huseyin [1 ]
Wang, Xiaojie [1 ]
Miller, Mark [1 ]
Liu, Yanming [1 ]
Gordaninejad, Faramarz [1 ]
机构
[1] Univ Nevada, Dept Mech Engn, Composite & Intelligent Mat Lab, Reno, NV 89557 USA
来源
关键词
DAMPERS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The response time of magnetorheological (MR) fluids to an external magnetic field is a few milliseconds. However, the overall response time in MR devices under a magnetic field is a function of electromagnetic parameters, the capabilities of the driving electronics, as well as, the operation conditions. Therefore, the overall response time of a MR device depends on the internal device design parameters. In this work, the response times of MR fluid and MR fluid valves have been studied under various flow configurations. Two types of valving geometries; annular flow, and radial flow are considered in the MR fluid valve designs. The transient pressure response of MR fluid valves are evaluated by using a diaphragm pump with a constant volume flow rate. The performance of each MR valve is characterized using a voltage step input, as well as, a current step input while recording the activation electric voltage/current, magnetic flux density, and pressure drop as a function of time. The variation of the response time of the MR valves under constant volume flow rate is experimentally investigated. The system's time constant is determined under induced pressure changes. In order to obtain the response time of the MR fluid a Maxwell model with a time constant is employed to describe the field induced pressure behavior of MR fluid under a steady flow. The results demonstrate that the pressure response times of the MR fluid and the MR valves depend on the designs of the electric parameters and the valve geometry. MR valves in annular flow geometry have a slow falling response time compared to their rising response time. MR valves in radial flow geometry result in faster pressure response times both in rising and falling states.
引用
收藏
页码:369 / 376
页数:8
相关论文
共 50 条
  • [41] Experimental study of response time of magnetorheological fluid damper
    Guan, X. C.
    Guo, P. F.
    Bian, C. F.
    Ou, J. P.
    INTERNATIONAL CONFERENCE ON SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, PTS 1-3, 2007, 6423
  • [42] Research on Dynamic Response Time of Magnetorheological Fluid Dampers
    Zhang, Jinqiu
    Zhang, Lei
    Yue, Jie
    Gao, Yongqiang
    Peng, Zhizhao
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING, PTS 1-3, 2013, 278-280 : 44 - 49
  • [43] Development of fast response MR-fluid actuator
    Takesue, N
    Kiyota, Y
    Furusho, J
    SICE 2002: PROCEEDINGS OF THE 41ST SICE ANNUAL CONFERENCE, VOLS 1-5, 2002, : 949 - 953
  • [44] A comprehensive analysis of the response time of MR dampers
    Koo, JH
    Goncalves, FD
    Ahmadian, M
    SMART MATERIALS AND STRUCTURES, 2006, 15 (02) : 351 - 358
  • [45] EFFECTS OF FLUID INERTIA AND COMPRESSIBILITY ON PERFORMANCE OF VALVES AND FLOW METERS OPERATING UNDER UNSTEADY CONDITIONS
    MCCLOY, D
    JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1966, 8 (01): : 52 - &
  • [46] 4d flow MR hemodynamic mapping of surgical pericardial valves
    Sturla, F.
    Piatti, F.
    Jaworek, M.
    Lucherini, F.
    Siryk, S.
    Geppert, C.
    Tresova, D.
    Pluchinotta, F.
    Vismara, R.
    Redaelli, A.
    Tasca, G.
    Lombardi, M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 403 - 404
  • [47] MR response of PdPtMn/CoFeB synthetic ferrimagnet biased spin-valves
    Noma, K
    Aoshima, K
    Kane, J
    Kanai, H
    IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (05) : 2940 - 2942
  • [48] An experimental study on the effects of temperature and magnetic field strength on the magnetorheological fluid stability and MR effect
    Rabbani, Yahya
    Ashtiani, Mahshid
    Hashemabadi, Seyed Hassan
    SOFT MATTER, 2015, 11 (22) : 4453 - 4460
  • [49] Response Time of Flow Transient Process of Magnetorheological Finishing
    Yang Hang
    Song Shupiao
    Zhang Shuai
    Gan Huan
    Huang Wen
    He Jianguo
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (03)
  • [50] Temperature rise characteristic of MR fluid in a multi-disc MR clutch under slip condition
    Wang, Daoming
    Hou, Youfu
    Tian, Zuzhi
    Meng, Qingrui
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2015, 67 (02) : 85 - 92