Performance results of a new DOI detector block for a high resolution PET-LSO research tomograph HRRT

被引:0
|
作者
Schmand, M [1 ]
Eriksson, L [1 ]
Casey, ME [1 ]
Andreaco, MS [1 ]
Melcher, C [1 ]
Wienhard, K [1 ]
Flugge, G [1 ]
Nutt, R [1 ]
机构
[1] CTI PET Syst Inc, Knoxville, TN USA
来源
1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2 | 1998年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To improve the spatial resolution and uniformity in modern high resolution brain PET systems over the entire field of view (FOV), it is necessary to archive the depth of interaction (DOI) information and correct for spatial resolution degradation. In this work we present the performance results of a high resolution LSO/GSO phoswich block detector with DOI capability. This detector design will be used in the new CTI High Resolution Research Tomograph, ECAT HRRT. The two crystal layer (19x19x7.5 mm(3)) and a light guide are stacked on each other and mounted on a (2x2) PMT set, so that the corners of the phoswich are positioned over the PMT centers. The crystal phoswich is cut into a 8x8 matrix of discrete crystals. The separation of the LSO and the GSO layer by pulse shape discrimination allows discrete DOI information to be obtained. The high light output and the light guide design results in an accurate identification of the 128 single crystals per block. Flood source measurements document a very good homogeneity of events, energy centroid stability and energy resolution (14-20% FWHM) per single crystal. An intrinsic resolution of similar to 1.3 nm and the DOI feasibility is extracted by coincidence measurements with a single GSO crystal.
引用
收藏
页码:934 / 938
页数:5
相关论文
共 50 条
  • [31] Impact of New Scatter Correction Strategies on High-Resolution Research Tomograph Brain PET Studies
    Syahir Mansor
    Ronald Boellaard
    Marc C. Huisman
    Bart N. M. van Berckel
    Robert C. Schuit
    Albert D. Windhorst
    Adriaan A. Lammertsma
    Floris H. P. van Velden
    Molecular Imaging and Biology, 2016, 18 : 627 - 635
  • [32] Impact of New Scatter Correction Strategies on High-Resolution Research Tomograph Brain PET Studies
    Mansor, Syahir
    Boellaard, Ronald
    Huisman, Marc C.
    van Berckel, Bart N. M.
    Schuit, Robert C.
    Windhorst, Albert D.
    Lammertsma, Adriaan A.
    van Velden, Floris H. P.
    MOLECULAR IMAGING AND BIOLOGY, 2016, 18 (04) : 627 - 635
  • [33] Effect of measurement uncertainty on region of interest based and parametric binding potential estimates for the high resolution research tomograph (HRRT)
    Sossi, Vesna
    Blinder, Stephan
    Rahmim, Arman
    Dinelle, Katherine
    Cheng, Kevin J-C
    Lidstone, Sarah C.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4539 - +
  • [34] VOXEL-WISE QUANTIFICATION OF [11C]CURB IN HUMAN BRAIN WITH THE HIGH RESOLUTION RESEARCH TOMOGRAPH (HRRT)
    Rusjan, P.
    Boileau, I.
    Tong, J.
    Mizrahi, R.
    Wilson, A.
    Houle, S.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 : 624 - 625
  • [35] Performance evaluation of a four-layer LSO detector for a small animal DOI PET scanner: jPET-RD
    Tsuda, T
    Murayama, H
    Kitamura, K
    Inadama, N
    Yamaya, T
    Yoshida, E
    Nishikido, F
    Hamamoto, M
    Kawai, H
    Ono, Y
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3321 - 3324
  • [36] Resolution improvement using tapered fiber for a high resolution PET block detector
    Yamamoto, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1074 - 1077
  • [37] Resolution improvement using tapered fiber for a high resolution PET block detector
    Yamamoto, S
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1442 - 1445
  • [38] Performance characteristics of the High Resolution Research Tomograph - Comparison of three prototypes
    de Jong, HWAM
    Knoess, C
    Lammertsma, AA
    Lenox, M
    Vollmar, S
    Casey, M
    Wienhard, K
    Heiss, WD
    Boellaard, R
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3437 - 3439
  • [39] Design of a High Resolution, Monolithic Crystal, PET/MRI Detector with DOI Positioning Capability
    Miyaoka, Robert S.
    Li, Xiaoli
    Lockhart, Cate
    Lewellen, Tom K.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3961 - +
  • [40] Calibration procedure for a DOI detector of high resolution PET through a Gaussian mixture model
    Yoshida, E
    Kimura, Y
    Kitamura, K
    Murayama, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2543 - 2549