Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes

被引:32
|
作者
Mynttinen, Elsi [1 ]
Wester, Niklas [2 ]
Lilius, Tuomas [3 ,4 ,5 ]
Kalso, Eija [3 ,5 ,6 ]
Mikladal, Bjorn [7 ]
Varjos, Ilkka [7 ]
Sainio, Sami [8 ]
Jiang, Hua [9 ]
Kauppinen, Esko I. [9 ]
Koskinen, Jari [2 ]
Laurila, Tomi [1 ]
机构
[1] Aalto Univ, Dept Elect Engn & Automat, Espoo 02150, Finland
[2] Aalto Univ, Dept Chem & Mat Sci, Espoo 02150, Finland
[3] Univ Helsinki, Dept Pharmacol, Helsinki 00290, Finland
[4] Univ Helsinki, Dept Clin Pharmacol, Helsinki 00290, Finland
[5] Helsinki Univ Hosp, Helsinki 00290, Finland
[6] Univ Helsinki, Pain Clin, Dept Anesthesiol Intens Care & Pain Med, Helsinki 00290, Finland
[7] Canatu Oy, Vantaa 01720, Finland
[8] SLAC Natl Accelerator Lab, Stanford Synchrotron Radiat Lightsource, Menlo Pk, CA 94025 USA
[9] Aalto Univ, Dept Appl Phys, Espoo 02150, Finland
关键词
X-RAY-ABSORPTION; VOLTAMMETRIC OXIDATION; HUMAN-PLASMA; DRUGS; ABUSE; SPECTROSCOPY; ALCOHOLS; CODEINE; NEXAFS; ACIDS;
D O I
10.1021/acs.analchem.0c00450
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Oxycodone is a strong opioid frequently used as an analgesic. Although proven efficacious in the management of moderate to severe acute pain and cancer pain, use of oxycodone imposes a risk of adverse effects such as addiction, overdose, and death. Fast and accurate determination of oxycodone blood concentration would enable personalized dosing and monitoring of the analgesic as well as quick diagnostics of possible overdose in emergency care. However, in addition to the parent drug, several metabolites are always present in the blood after a dose of oxycodone, and to date, there is no electrochemical data available on any of these metabolites. In this paper, a single-walled carbon nanotube (SWCNT) electrode and a Nafion-coated SWCNT electrode were used, for the first time, to study the electrochemical behavior of oxycodone and its two main metabolites, noroxycodone and oxymorphone. Both electrode types could selectively detect oxycodone in the presence of noroxycodone and oxymorphone. However, we have previously shown that addition of a Nafion coating on top of the SWCNT electrode is essential for direct measurements in complex biological matrices. Thus, the Nafion/SWCNT electrode was further characterized and used for measuring clinically relevant concentrations of oxycodone in buffer solution. The limit of detection for oxycodone with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5-10 mu M in buffer solution. This study shows that the fabricated Nafion/SWCNT sensor has potential to be applied in clinical concentration measurements.
引用
收藏
页码:8218 / 8227
页数:10
相关论文
共 50 条
  • [21] Electrochemical behavior and determination of uric acid at single-walled carbon nanotube modified gold electrodes
    Wei, SG
    Zhao, FQ
    Zeng, BZ
    MICROCHIMICA ACTA, 2005, 150 (3-4) : 219 - 224
  • [22] Fabrication and electrochemical properties of free-standing single-walled carbon nanotube film electrodes
    牛志强
    马文君
    董海博
    李金柱
    周维亚
    Chinese Physics B, 2011, 20 (02) : 514 - 520
  • [23] Fabrication and electrochemical properties of free-standing single-walled carbon nanotube film electrodes
    Niu Zhi-Qiang
    Ma Wen-Jun
    Dong Hai-Bo
    Li Jin-Zhu
    Zhou Wei-Ya
    CHINESE PHYSICS B, 2011, 20 (02)
  • [24] Effect of electrochemical functionalization of single-walled carbon nanotube electrodes in flexible enzymatic biofuel cells
    Momaya, Divyang
    Ohno, Yutaka
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2021, 60 (06)
  • [25] Electrochemical Behavior and Determination of Uric Acid at Single-Walled Carbon Nanotube Modified Gold Electrodes
    Shuhong Wei
    Faqiong Zhao
    Baizhao Zeng
    Microchimica Acta, 2005, 150 : 219 - 224
  • [26] Electron Transfer Kinetics at Single-Walled Carbon Nanotube Electrodes using Scanning Electrochemical Microscopy
    Dumitrescu, Ioana
    Dudin, Petr V.
    Edgeworth, Jonathan P.
    Macpherson, Julie V.
    Unwin, Patrick R.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (06): : 2633 - 2639
  • [27] Comparison of double-walled with single-walled carbon nanotube electrodes by electrochemistry
    Moore, Katherine E.
    Flavel, Benjamin S.
    Ellis, Amanda V.
    Shapter, Joseph G.
    CARBON, 2011, 49 (08) : 2639 - 2647
  • [28] Electrochemical properties of high-power supercapacitors using single-walled carbon nanotube electrodes
    An, KH
    Kim, WS
    Park, YS
    Moon, JM
    Bae, DJ
    Lim, SC
    Lee, YS
    Lee, YH
    ADVANCED FUNCTIONAL MATERIALS, 2001, 11 (05) : 387 - 392
  • [29] Single-Walled Carbon Nanotube-Coated Flexible and Soft Screen-Printed Electrochemical Biosensor for Ochratoxin A Detection
    Abera, Biresaw Demelash
    Shkodra, Bajramshahe
    Douaki, Ali
    Ibba, Pietro
    Cantarella, Giuseppe
    Petti, Luisa
    Lugli, Paolo
    2020 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2020,
  • [30] Chemical detection with a single-walled carbon nanotube capacitor
    Snow, ES
    Perkins, FK
    Houser, EJ
    Badescu, SC
    Reinecke, TL
    SCIENCE, 2005, 307 (5717) : 1942 - 1945