The combination of intraoperative CT navigation and C-arm fluoroscopy for INFIX and percutaneous TITS screw placement in the treatment of pelvic ring injury: technical note

被引:5
|
作者
Hiyama, Akihiko [1 ]
Ukai, Taku [1 ]
Nomura, Satoshi [1 ]
Watanabe, Masahiko [1 ]
机构
[1] Tokai Univ, Sch Med, Dept Orthopaed Surg, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
关键词
Internal pelvic fixator; Transiliac-transsacral screw; Pelvic ring fracture; Intraoperative CT navigation; C-arm fluoroscopy; Pelvic ring injury; FIXATION; EMBOLIZATION; MANAGEMENT; FRACTURE; OUTCOMES; PATIENT;
D O I
10.1186/s13018-022-02920-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The subcutaneous screw rod system, commonly known as the internal pelvic fixator (INFIX), is useful in managing unstable pelvic ring fractures. Conventional INFIX and transiliac-transsacral (TITS) screw techniques are performed using C-arm fluoroscopy. There have been problems with medical exposure and screw insertion accuracy with these techniques. This work describes new INFIX and TITS techniques using intraoperative computed tomography (CT) navigation and C-arm fluoroscopy for pelvic ring fracture. Methods A typical case is presented in this study. An 86-year-old woman suffered from an unstable pelvic ring fracture due to a fall from a height. INFIX and TITS screw fixation with intraoperative CT navigation were selected to optimize surgical invasiveness and proper implant placement. Results The patient was placed in a supine position on a Jackson table. An intraoperative CT navigation was imaged, and screws were inserted under the navigation. Postoperative X-rays and CT confirmed that the screw was inserted correctly. This technique was less invasive to the patient and had little radiation exposure to the surgeon. Rehabilitation of walking practice was started early after the surgery, and she was able to walk with the assistance of a walker by the time of transfer. Conclusions The technique employed in our case study has the cumulative advantages of safety, accuracy, and reduced radiation exposure, together with the inherent advantages of functional outcomes of previously reported INFIX and TITS screw techniques. Further experience with this approach will refine this technique to overcome its limitations and facilitate its wider use.
引用
收藏
页数:8
相关论文
共 34 条
  • [21] Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation
    Kim, Terrence T.
    Drazin, Doniel
    Shweikeh, Faris
    Pashman, Robert
    Johnson, J. Patrick
    NEUROSURGICAL FOCUS, 2014, 36 (03)
  • [22] Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines: Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm® Guided Methods
    Shin, Myung-Hoon
    Ryu, Kyeong-Sik
    Park, Chun-Kun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2012, 52 (03) : 204 - 209
  • [23] Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation
    Liu Ya-jun
    Tian Wei
    Liu Bo
    Li Qin
    Hu Lin
    Li Zhi-yu
    Yuan Qiang
    Lue Yan-wei
    Sun Yu-zhen
    CHINESE MEDICAL JOURNAL, 2010, 123 (21) : 2995 - 2998
  • [24] Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for C1 Lateral Mass and C2 Pedicle Screw Placement for Atlantoaxial Instability
    Yang, Yong Liang
    Zhou, Dong Sheng
    He, Ji Liang
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (03): : 127 - 134
  • [25] A novel technique of cervical pedicle screw placement with a pilot screw under the guidance of intraoperative 3D imaging from C-arm cone-beam CT without navigation for safe and accurate insertion
    Masahiko Takahata
    Katsuhisa Yamada
    Iwata Akira
    Tsutomu Endo
    Hideki Sudo
    Hidetoki Yokoyama
    Norimasa Iwasaki
    European Spine Journal, 2018, 27 : 2754 - 2762
  • [26] A novel technique of cervical pedicle screw placement with a pilot screw under the guidance of intraoperative 3D imaging from C-arm cone-beam CT without navigation for safe and accurate insertion
    Takahata, Masahiko
    Yamada, Katsuhisa
    Akira, Iwata
    Endo, Tsutomu
    Sudo, Hideki
    Yokoyama, Hidetoki
    Iwasaki, Norimasa
    EUROPEAN SPINE JOURNAL, 2018, 27 (11) : 2754 - 2762
  • [27] Aortic arch injection with C-arm cone beam CT for radiosurgery treatment planning of cerebral arteriovenous malformations: technical note
    Radvany, Martin G.
    Ehtiati, Tina
    Huang, Judy
    Mahesh, Mahadevappa
    Gailloud, Philippe
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2012, 4 (05)
  • [28] CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: Accuracy of screw position, injury reduction and complications in 71 patients with 136 screws
    Pieske, Oliver
    Landersdorfer, Christoph
    Trumm, Christoph
    Greiner, Axel
    Wallmichrath, Jens
    Gottschalk, Oliver
    Rubenbauer, Bianka
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (02): : 333 - 339
  • [29] Comparison of the Accuracy of Pedicle Screw Placement Using a Fluoroscopy-Assisted Free-Hand Technique with Robotic-Assisted Navigation Using an O-Arm or 3D C-Arm in Scoliosis Surgery
    Li, Chao
    Li, Hao
    Su, Junxiao
    Wang, Zheng
    Li, Donglai
    Tian, Yonghao
    Yuan, Suomao
    Wang, Lianlei
    Liu, Xinyu
    GLOBAL SPINE JOURNAL, 2024, 14 (04) : 1337 - 1346
  • [30] Comparison of Cranial Facet Joint Violation Rates Between Open and Percutaneous Pedicle Screw Placement Using Intraoperative 3-D CT (O-arm) Computer Navigation
    Yson, Sharon C.
    Sembrano, Jonathan N.
    Sanders, Peter C.
    Santos, Edward Rainier G.
    Ledonio, Charles Gerald T.
    Polly, David W., Jr.
    SPINE, 2013, 38 (04) : E251 - E258