The combination of intraoperative CT navigation and C-arm fluoroscopy for INFIX and percutaneous TITS screw placement in the treatment of pelvic ring injury: technical note

被引:5
|
作者
Hiyama, Akihiko [1 ]
Ukai, Taku [1 ]
Nomura, Satoshi [1 ]
Watanabe, Masahiko [1 ]
机构
[1] Tokai Univ, Sch Med, Dept Orthopaed Surg, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
关键词
Internal pelvic fixator; Transiliac-transsacral screw; Pelvic ring fracture; Intraoperative CT navigation; C-arm fluoroscopy; Pelvic ring injury; FIXATION; EMBOLIZATION; MANAGEMENT; FRACTURE; OUTCOMES; PATIENT;
D O I
10.1186/s13018-022-02920-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The subcutaneous screw rod system, commonly known as the internal pelvic fixator (INFIX), is useful in managing unstable pelvic ring fractures. Conventional INFIX and transiliac-transsacral (TITS) screw techniques are performed using C-arm fluoroscopy. There have been problems with medical exposure and screw insertion accuracy with these techniques. This work describes new INFIX and TITS techniques using intraoperative computed tomography (CT) navigation and C-arm fluoroscopy for pelvic ring fracture. Methods A typical case is presented in this study. An 86-year-old woman suffered from an unstable pelvic ring fracture due to a fall from a height. INFIX and TITS screw fixation with intraoperative CT navigation were selected to optimize surgical invasiveness and proper implant placement. Results The patient was placed in a supine position on a Jackson table. An intraoperative CT navigation was imaged, and screws were inserted under the navigation. Postoperative X-rays and CT confirmed that the screw was inserted correctly. This technique was less invasive to the patient and had little radiation exposure to the surgeon. Rehabilitation of walking practice was started early after the surgery, and she was able to walk with the assistance of a walker by the time of transfer. Conclusions The technique employed in our case study has the cumulative advantages of safety, accuracy, and reduced radiation exposure, together with the inherent advantages of functional outcomes of previously reported INFIX and TITS screw techniques. Further experience with this approach will refine this technique to overcome its limitations and facilitate its wider use.
引用
收藏
页数:8
相关论文
共 34 条
  • [1] The combination of intraoperative CT navigation and C-arm fluoroscopy for INFIX and percutaneous TITS screw placement in the treatment of pelvic ring injury: technical note
    Akihiko Hiyama
    Taku Ukai
    Satoshi Nomura
    Masahiko Watanabe
    Journal of Orthopaedic Surgery and Research, 17
  • [2] Advancements in pelvic ring fracture surgery: Assessing INFIX screw placement accuracy with CT navigation
    Hiyama, Akihiko
    Ukai, Taku
    Tanaka, Tatsumi
    Watanabe, Masahiko
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (07):
  • [3] O-arm navigation for sacroiliac screw placement in the treatment for posterior pelvic ring injury
    Shengyu Lu
    Keqin Yang
    Cailing Lu
    Ping’ou Wei
    Zhi Gan
    Zhipeng Zhu
    Haitao Tan
    International Orthopaedics, 2021, 45 : 1803 - 1810
  • [4] O-arm navigation for sacroiliac screw placement in the treatment for posterior pelvic ring injury
    Lu, Shengyu
    Yang, Keqin
    Lu, Cailing
    Wei, Ping'ou
    Gan, Zhi
    Zhu, Zhipeng
    Tan, Haitao
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1803 - 1810
  • [5] Technical note: A comparison of physician doses in C-Arm and CT fluoroscopy procedures
    Troville, Jonathan
    Knott, Emily
    Reynoso-Mejia, Carlos Alberto
    Wagner, Martin
    Lee, Fred T.
    Szczykutowicz, Timothy P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):
  • [6] Technical and clinical outcome of percutaneous CT fluoroscopy-guided screw placement in unstable injuries of the posterior pelvic ring
    Frederik F. Strobl
    Sophia M. Haeussler
    Philipp M. Paprottka
    Ralf-Thorsten Hoffmann
    Oliver Pieske
    Maximilian F. Reiser
    Christoph G. Trumm
    Skeletal Radiology, 2014, 43 : 1093 - 1100
  • [7] Technical and clinical outcome of percutaneous CT fluoroscopy-guided screw placement in unstable injuries of the posterior pelvic ring
    Strobl, Frederik F.
    Haeussler, Sophia M.
    Paprottka, Philipp M.
    Hoffmann, Ralf-Thorsten
    Pieske, Oliver
    Reiser, Maximilian F.
    Trumm, Christoph G.
    SKELETAL RADIOLOGY, 2014, 43 (08) : 1093 - 1100
  • [8] Minimally Invasive Percutaneous Modified Iliac Screw Placement Using Intraoperative Navigation: A Technical Note
    Tanasansomboon, Teerachat
    Tejapongvorachai, Tawechai
    Yingsakmongkol, Wicharn
    Limthongkul, Worawat
    Kotheeranurak, Vit
    Singhatanadgige, Weerasak
    WORLD NEUROSURGERY, 2021, 146 : 240 - 245
  • [9] Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
    Giuseppe La Rocca
    Edoardo Mazzucchi
    Fabrizio Pignotti
    Luigi Aurelio Nasto
    Gianluca Galieri
    Alessandro Olivi
    Vincenzo De Santis
    Pierluigi Rinaldi
    Enrico Pola
    Giovanni Sabatino
    Journal of Orthopaedics and Traumatology, 2022, 23
  • [10] Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
    Wei-Xing Xu
    Wei-Guo Ding
    Bin Xu
    Tian-Hong Hu
    Hong-Feng Sheng
    Jia-Fu Zhu
    Xiao-Long Zhu
    BMC Musculoskeletal Disorders, 21