Bone marrow edema around the hip in non-traumatic pain: dual-energy CT vs MRI

被引:22
|
作者
Foti, Giovanni [1 ]
Faccioli, Niccolo [2 ]
Silva, Ronaldo [3 ]
Oliboni, Eugenio [1 ]
Zorzi, Claudio [4 ]
Carbognin, Giovanni [1 ]
机构
[1] IRCCS Sacro Cuore Don Calabria Hosp, Dept Radiol, Via Don A Sempreboni 10, I-37024 Negrar, Italy
[2] Verona Univ Hosp, Dept Radiol, Verona, Italy
[3] IRCCS Sacro Cuore Don Calabria Hosp, Clin Res Unit, Negrar, Italy
[4] IRCCS Sacro Cuore Don Calabria Hosp, Dept Orthoped Surg, Negrar, Italy
关键词
Hip joint; Magnetic resonance imaging; Multidetector computed tomography; Bone marrow; FEMORAL-HEAD; TRANSIENT OSTEOPOROSIS; CORE DECOMPRESSION; OSTEONECROSIS; RELIABILITY; FRACTURES; NECROSIS; LESIONS; UPDATE;
D O I
10.1007/s00330-020-06775-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) in identifying bone marrow edema (BME) around the hip joint in non-traumatic patients. Methods This prospective IRB-approved study was conducted between January 2019 and October 2019 and included 59 consecutive patients (18 males, 41 females; mean age 61.5 years, range 32-82) who were assessed by DECT and magnetic resonance imaging (MRI) within a 5-day period. Diagnostic accuracy values for diagnosing BME on a per-patient and on a per-partition-basis analysis were calculated for DECT images by two readers (R1 and R2, with 15 and 10 years of experience, respectively), using MRI as reference for diagnosis. Inter-observer agreements were calculated withk-statistics. Apvalue of < 0.05 was considered as statistically significant. Results MRI depicted BME in 44/59 patients (74.58%), with the involvement of 83/708 (11.72%) partitions. The sensitivity, specificity, and accuracy of R1 and R2 were 95.45% (42/44), 86.67% (13/15), and 93.22% (55/59) for R1, and 86.36% (38/44), 80.00% (12/15), and 84.75% (50/59) for R2. For both readers, the BME detection rate was higher in patients with severe edema (100%) in comparison to patients with mild edema (91.30% and 73.91%). In the partition-basis analysis, sensitivity, specificity, and accuracy ranges were 33.3 to 100%, 91.84 to 100%, and 88.14 to 100%, respectively. The inter-observer agreement for patients' analysis was substantial (k = 0.7065), whereas for partition analysis ranged from fair (k = 0.2976) to near-perfect (k = 1.000). Conclusion DECT can accurately identify BME around the hip joint, in comparison to MRI.
引用
收藏
页码:4098 / 4106
页数:9
相关论文
共 50 条
  • [41] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Foti, Giovanni
    Beltramello, Alberto
    Catania, Matteo
    Rigotti, Stefano
    Serra, Gerardo
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (06): : 487 - 494
  • [42] Dual-Energy CT of Material Decomposition Analysis for Detection with Bone Marrow Edema in Patients with Vertebral Compression Fractures
    Akisato, Kyouhei
    Nishihara, Reisuke
    Okazaki, Hajime
    Masuda, Takanori
    Hironobe, Ayako
    Ishizaki, Hiromi
    Shota, Kondo
    Yamaguchi, Hiroshi
    Funama, Yoshinori
    ACADEMIC RADIOLOGY, 2020, 27 (02) : 227 - 232
  • [43] Traumatic bone marrow edema of the calcaneus: Evaluation of color-coded virtual non-calcium dual-energy CT in a multi-reader diagnostic accuracy study
    Booz, Christian
    Noeske, Jochen
    Albrecht, Moritz H.
    Lenga, Lukas
    Martin, Simon S.
    Wichmann, Julian L.
    Huizing, Nicole A.
    Eichler, Katrin
    Nour-Eldin, Nour-Eldin A.
    Vogl, Thomas J.
    Yel, Ibrahim
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 118 : 207 - 214
  • [44] Detection of different degree traumatic vertebral bone marrow oedema by virtual non-calcium technique of dual-source dual-energy CT
    Wang, Y.
    Chen, Y.
    Zheng, H.
    Huang, X.
    Shan, C.
    Bao, Y.
    CLINICAL RADIOLOGY, 2020, 75 (02) : 156.e11 - 156.e19
  • [45] Diagnostic Performance of Dual-Energy CT for the Detection of Traumatic Bone Marrow Lesions in the Ankle: Comparison with MR Imaging
    Guggenberger, Roman
    Gnannt, Ralph
    Hodler, Juerg
    Krauss, Bernhard
    Wanner, Guido A.
    Csuka, Esther
    Payne, Barbara
    Frauenfelder, Thomas
    Andreisek, Gustav
    Alkadhi, Hatem
    RADIOLOGY, 2012, 264 (01) : 164 - 173
  • [46] Diagnostic accuracy of color-coded virtual noncalcium dual-energy CT for the assessment of bone marrow edema in sacral insufficiency fracture in comparison to MRI
    Booz, Christian
    Noeske, Jochen
    Albrecht, Moritz H.
    Lenga, Lukas
    Martin, Simon S.
    Bucher, Andreas M.
    Huizinga, Nicole A.
    Wichmann, Julian L.
    Vogl, Thomas J.
    Yel, Ibrahim
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [47] Diagnostic efficacy of dual-energy CT virtual non-calcium technique in the diagnosis of bone marrow edema of sacroiliac joints in ankylosing spondylitis
    Lu, Hongyue
    Li, Zhi
    Liang, Ziheng
    Liu, Yuqi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [48] Diagnostic Value of Dual-Energy CT Virtual Noncalcium for the Assessment of Bone Marrow Edema of Wrist in Patients with Rheumatoid Arthritis
    Xu, Guodong
    Qian, Jie
    Yang, Yekun
    Ding, Yuchen
    Chen, Yingchi
    Li, Xingcan
    Zhang, Yucheng
    Jia, Zhongzheng
    ACADEMIC RADIOLOGY, 2024, 31 (09) : 3740 - 3748
  • [49] Feasibility of Dual-Energy Cone-Beam CT of Bone Marrow Edema Using Dual-Layer Flat Panel Detectors
    Liu, Stephen Z.
    Zhao, Chumin
    Herbst, Magdalena
    Weber, Thomas
    Vogt, Sebastian
    Ritschl, Ludwig
    Kappler, Steffen
    Siewerdsen, Jeffrey H.
    Zbijewski, Wojciech
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [50] Use of dual-energy CT to detect and depict bone marrow oedema in rheumatoid arthritis: is it ready to substitute MRI?
    Wu, Haijun
    Zhang, Guangfeng
    Huang, Xiaoyu
    Liang, Changhong