Reliability Analysis of the 3-min All-Out Exercise Test for Cycle Ergometry

被引:55
|
作者
Johnson, Tyler M.
Sexton, Patrick J.
Placek, Ashley M.
Murray, Steven R. [2 ]
Pettitt, Robert W. [1 ]
机构
[1] Minnesota State Univ, Dept Human Performance, ATC, CSCS,Viola Holbrook Human Performance Lab, Mankato, MN 56001 USA
[2] Colorado Mesa Univ, Dept Kinesiol, Grand Junction, CO USA
来源
关键词
ANAEROBIC CAPACITY; CRITICAL POWER; POWER-DURATION RELATIONSHIP; MAXIMUM OXYGEN UPTAKE; MAXIMAL OXYGEN-UPTAKE; CRITICAL POWER; WORK CAPACITY; ANAEROBIC THRESHOLD; UPTAKE KINETICS; O-2; UPTAKE; VO2MAX; TOLERANCE; CRITERIA; CONSTANT;
D O I
10.1249/MSS.0b013e318224cb0f
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
JOHNSON, T. M., P. J. SEXTON, A. M. PLACEK, S. R. MURRAY, and R. W. PETTITT. Reliability Analysis of the 3-min All-Out Exercise Test for Cycle Ergometry. Med. Sci. Sports Exerc., Vol. 43, No. 12, pp. 2375-2380, 2011. The 3-min all-out exercise test (3 MT) is purported to estimate critical power (CP) and anaerobic work capacity (W') and serve as an exercise mode for measuring maximum oxygen uptake ((V) over dotO(2max)). Reliability analysis of the 3 MT has been confined to CP, not W', and verification of "true" (V) over dotO(2max) was exclusive to a graded exercise test (GXT). Purpose: We conducted a reliability analysis of the 3 MT and compared (V) over dotO(2max) values from the 3 MT with a GXT and an exhaustive square-wave verification bout. Methods: Upon completion of a custom GXT and square-wave verification protocol, 11 subjects of various aerobic powers completed two 3 MTs (separate visits). CP, W', average power during 150 s from the 3 MT, and (V) over dotO(2max) values were assessed using typical error (TE), coefficient of variation (CV), and intraclass correlation (alpha). Results: CP (W) (trial 1 = 206 +/- 47, trial 2 = 206 +/- 42) did not differ between 3 MT trials (P = 0.37) and was reliable (TE = 15 W, CV = 7%, alpha = 0.93). W' was less reliable (TE = 2864 J, CV = 28%, alpha = 0.76) but did not alter power-duration estimates from the two 3 MTs (P > 0.05). Variability for (V) over dotO(2max) (TE (mL.kg(-1).min(-1))) between the GXT and the verification bout (1.16) was more consistent than the first (2.03) or second (2.69) 3 MT. Conclusions: The 3 MT yields reliable estimates of CP and consistent estimates of the power-duration relationship. Power for 150 s, in comparison with W', is a more reliable metric of short-term power performance. The square-wave protocol is recommended over the 3 MT for verifying true (V) over dotO(2max).
引用
收藏
页码:2375 / 2380
页数:6
相关论文
共 50 条
  • [11] Repeatability and Variability of the 3-Min All-Out Test at the Subject Level
    Vijay Sarthy M. Sreedhara
    Gregory M. Mocko
    Randolph E. Hutchison
    Journal of Science in Sport and Exercise, 2023, 5 : 77 - 86
  • [12] Load Determination for the 3-Minute All-Out Exercise Test for Cycle Ergometry
    Dicks, Nathan D.
    Jamnick, Nicholas A.
    Murray, Steven R.
    Pettitt, Robert W.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2016, 11 (02) : 197 - 203
  • [13] Test-retest reliability of a 3-min isokinetic all-out test using two different cadences
    de Lucas, Ricardo Dantas
    Greco, Camila Coelho
    Dekerle, Jeanne
    Correa Carita, Renato Aparecido
    Antonacci Guglielmo, Luiz Guilherme
    Denadai, Benedito Sergio
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2014, 17 (06) : 645 - 649
  • [14] Validity and reliability of the 3-min all-out running test to measure critical velocity in hot environments
    Kuo, Yu-Hsuan
    Cheng, Ching-Feng
    Hsu, Wei-Chieh
    Wong, Del P.
    RESEARCH IN SPORTS MEDICINE, 2017, 25 (04) : 470 - 479
  • [15] Determination of critical power using a 3-min all-out cycling test
    Vanhatalo, Anni
    Doust, Jonathan H.
    Burnley, Mark
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (03): : 548 - 555
  • [16] Responses during exhaustive exercise at critical power determined from the 3-min all-out test
    Bergstrom, Haley C.
    Housh, Terry J.
    Zuniga, Jorge M.
    Traylor, Daniel A.
    Lewis, Robert W.
    Camic, Clayton L.
    Schmidt, Richard J.
    Johnson, Glen O.
    JOURNAL OF SPORTS SCIENCES, 2013, 31 (05) : 537 - 545
  • [17] A 3-min all-out cycling test is sensitive to a change in critical power
    Vanhatalo, Anni
    Doust, Jonathan H.
    Burnley, Mark
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (09): : 1693 - 1699
  • [18] Determination Of Critical Power In Rowing By Using 3-min All-out Test
    Cheng, Ching-Feng
    Yang, Yi-Shan
    Lin, Hui-Mei
    Lee, Chia-Lun
    Wang, Chun-Yi
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 947 - 947
  • [19] High-intensity Cycling Intervals Are Prescribed Accurately Using The 3-min All-out Exercise Test
    Dicks, Nathan D.
    Roloff, Zachery A.
    Krynski, Luke M.
    Pettitt, Robert W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 567 - 567
  • [20] Effects of Prior Voluntary Hyperventilation on the 3-min All-Out Cycling Test in Men
    Johnson, Michael A.
    Sharpe, Graham R.
    Needham, Robert S.
    Williams, Neil C.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2021, 53 (07) : 1482 - 1494