Probe calibration for freehand 3-D ultrasound

被引:87
|
作者
Lindseth, F [1 ]
Tangen, GA [1 ]
Lango, T [1 ]
Bang, J [1 ]
机构
[1] SINTEF, Unimed Ultrasound, N-7465 Trondheim, Norway
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2003年 / 29卷 / 11期
关键词
utrasound probe calibration; freehand 3-D ultrasound reconstruction; ultrasound-based surgical navigation; image-guided therapy; phantom study; accuracy evaluation; automatic point detection; image processing;
D O I
10.1016/S0301-5629(03)01012-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound (US) probe calibration establishes the rigid body transformation between the US image and a tracking device attached to the probe. This is an important requirement for correct 3-D reconstruction of freehand US images and, thus, for accurate surgical navigation based on US. In this study, we evaluated three methods for probe calibration, based on a single-point phantom, a wire-cross phantom requiring 2-D alignment and a wire phantom for freehand scanning. The processing of acquired data is fairly common to these methods and, to a great extent, based on automated procedures. The evaluation is based on quality measures in 2-D and 3-D reconstructed data. With each of the three methods, we calibrated a linear-array probe, a phased-array sector probe and an intraoperative probe. The freehand method performed best, with a 3-D navigation accuracy of 0.6 mm for one of the probes. This indicates that clinical accuracy in the order of I mm may be achieved in US-based surgical navigation.
引用
收藏
页码:1607 / 1623
页数:17
相关论文
共 50 条
  • [41] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471
  • [42] Freehand 3D ultrasound calibration using an electromagnetically tracked needle
    Zhang, Hui
    Banovac, Filip
    White, Amy
    Cleary, Kevin
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [43] Probe Localization for Freehand 3D Ultrasound by Tracking Skin Features
    Sun, Shih-Yu
    Gilbertson, Matthew
    Anthony, Brian W.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT II, 2014, 8674 : 365 - 372
  • [44] A novel temporal calibration method for 3-D ultrasound
    Rousseau, Francois
    Hellier, Pierre
    Barillot, Christian
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (08) : 1108 - 1112
  • [45] MEASURING FEMORAL TORSION IN VIVO USING FREEHAND 3-D ULTRASOUND IMAGING
    Passmore, Elyse
    Pandy, Marcus G.
    Graham, H. Kerr
    Sangeux, Morgan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (02): : 619 - 623
  • [46] Use of 3-d freehand endorectal ultrasound system with appropriate rectal phantom
    Warmath, JR
    Herline, AJ
    Galloway, RL
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1137 - 1140
  • [47] Calibration algorithm for freehand ultrasound
    Rao, Yao
    Peng, Yao
    Journal of Theoretical and Applied Information Technology, 2012, 45 (02) : 688 - 693
  • [48] 3-D calibration method and algorithm for freehand image of phased array ultrasonic testing
    Yao Rao
    Jia Cili
    Lu Wenhua
    Cheng Minye
    Yao Peng
    JOURNAL OF VIBROENGINEERING, 2014, 16 (04) : 1679 - 1688
  • [49] 3-D calibration method and algorithm for freehand image of phased array ultrasonic testing
    Rao, Y. (yaorao@2008.sina.com), 1679, Vibromechanika (16):
  • [50] Confhusius: A robust and fully automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    MEDICAL IMAGE ANALYSIS, 2005, 9 (01) : 25 - 38