First report for the electrochemical investigation of a new HIV integrase inhibitor dolutegravir: Its voltammetric determination in tablet dosage forms and human urine using a boron-doped diamond electrode

被引:13
|
作者
Allahverdiyeva, Shabnam [1 ]
Pinar, Pinar Talay [2 ]
Yardim, Yavuz [2 ]
Senturk, Zuhre [3 ]
机构
[1] Van Yuzuncu Yil Univ, Fac Sci, Dept Biochem, TR-65080 Van, Turkey
[2] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkey
[3] Van Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkey
关键词
Dolutegravir; Boron-doped diamond electrode; Square-wave adsorptive stripping voltammetry; Tablets; Urine; SIMULTANEOUS QUANTIFICATION; ANTIRETROVIRAL AGENTS; LIQUID-CHROMATOGRAPHY; MS/MS METHOD; DRUG; ELVITEGRAVIR; COBICISTAT; LAMIVUDINE; PLASMA;
D O I
10.1016/j.diamond.2021.108332
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, for the first time, the study of electrochemical investigation and voltammetric determination of HIV integrase inhibitor dolutegravir was described. The effect of pretreatment (anodically or cathodically) of borondoped diamond electrode was investigated in detail on the stripping voltammetric performance for this compound. Dolutegravir presented one or two oxidation peaks within the pH range 2.0-12.0 by using both pretreated electrodes. Employing square-wave stripping mode on the surface of cathodically pretreated boron-doped diamond electrode (after 60 s accumulation at +0.3 V) in Britton-Robinson buffer at pH 10.0, there was a linear dependence of the peak current at +0.79 V (vs. Ag/AgCl, 3 M NaCl) and dolutegravir concentration in the range of 1.0-50.0 mu g mL(-1) (2.38 x 10(-6) -1.19 x 10(-4) M), with a detection limit of 0.26 mu g mL(-1) (6.20 x 10(-7) M). The applicability of the developed approach for the quantification of dolutegravir was tested in the commercial tablet formulations and model human urine samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] First Report for the Electrooxidation of Antifungal Anidulafungin: Application to its Voltammetric Determination in Parenteral Lyophilized Formulation Using a Boron-doped Diamond Electrode in the Presence of Anionic Surfactant
    Ozok, Hande Izem
    Allahverdiyeva, Shabnam
    Yardim, Yavuz
    Senturk, Zuhre
    ELECTROANALYSIS, 2022, 34 (09) : 1487 - 1498
  • [32] Voltammetric determination of daminozide and its degradation product N,N-dimethylhydrazine using a boron-doped diamond electrode
    Usenko, Alona
    Chylkova, Jaromira
    Selesovska, Renata
    Sedlak, Milos
    Vana, Jiroi
    Bartacek, Jan
    Mikysek, Tomas
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 904
  • [33] Osteryoung square wave voltammetric determination of phenazopyridine hydrochloride in human urine and tablet dosage forms based on electrochemical reduction at carbon paste electrode
    Citak, Meryem
    Yilmaz, Selahattin
    Dilgin, Yusuf
    Tuerker, Guelen
    Yagmur, Sultan
    Erdugan, Hueseyin
    Erdugan, Necla
    CURRENT PHARMACEUTICAL ANALYSIS, 2007, 3 (02) : 141 - 145
  • [34] An advanced approach for electrochemical sensing of ibuprofen in pharmaceuticals and human urine samples using a bare boron-doped diamond electrode
    Svorc, Lubomir
    Strezova, Ivana
    Kianickova, Kristina
    Stankovic, Dalibor M.
    Otrisal, Pavel
    Samphao, Anchalee
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 822 : 144 - 152
  • [35] Square-wave voltammetric determination of hydroxychloroquine in pharmaceutical and synthetic urine samples using a cathodically pretreated boron-doped diamond electrode
    Deroco, Patricia Batista
    Vicentini, Fernando Campanha
    Oliveira, Geiser Gabriel
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 719 : 19 - 23
  • [36] Sensitive Voltammetric Method for Piroxicam Determination in Pharmaceutical, Urine and Tap Water Samples using an Anodically Pretreated Boron-Doped Diamond Electrode
    Rosseto, Hallyssonn Augusto Pires
    Matos, Roberto
    Medeiros, Roberta Antigo
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 5 (18): : 40 - 50
  • [37] First report for the voltammetric determination of Lamivudine anti-HIV drug in tablet dosage forms by glassy carbon electrode modified with polyaniline nanowires
    Nosrati, Mahtab
    Rafati, Amir Abbas
    Bagheri, Ahmad
    Assari, Parnaz
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (10):
  • [38] Anodic behavior of sertindole and its voltammetric determination in pharmaceuticals and human serum using glassy carbon and boron-doped diamond electrodes
    Altun, Yuksel
    Dogan-Topal, Burcu
    Uslu, Bengi
    Ozkan, Sibel A.
    ELECTROCHIMICA ACTA, 2009, 54 (06) : 1893 - 1903
  • [39] First electrochemical evaluation of favipiravir used as an antiviral option in the treatment of COVID-19: A study of its enhanced voltammetric determination in cationic surfactant media using a boron-doped diamond electrode
    Allahverdiyeva, Shabnam
    Yunusoglu, Oruc
    Yardim, Yavuz
    Senturk, Zuhre
    ANALYTICA CHIMICA ACTA, 2021, 1159
  • [40] Anodic behaviour of fulvestrant and its voltammetric determination in pharmaceuticals and human serum on highly boron-doped diamond electrode using differential pulse adsorptive stripping voltammetry
    B. Dogan-Topal
    Dilek Kul
    Sibel A. Ozkan
    B. Uslu
    Journal of Applied Electrochemistry, 2011, 41 : 1253 - 1260