Design and simulation of two phase hollow fiber contactors for simultaneous membrane based solvent extraction and stripping of organic acids and bases

被引:26
|
作者
Kertész, R [1 ]
Schlosser, S [1 ]
机构
[1] Slovak Univ Technol Bratislava, Dept Chem & Biochem Engn, Bratislava 81237, Slovakia
关键词
design; simulation; hollow fiber contactors; membrane based solvent extraction; membrane based solvent stripping; butyric acid; organic acids;
D O I
10.1016/j.seppur.2004.09.007
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A short-cut method for the design and simulation of two-phase hollow fiber (HF) contactors with variable mass-transfer and distribution coefficients taking into account reaction kinetics is presented. A parametric study of membrane based solvent extraction (MBSE) and stripping (MBSS) of butyric acid (BA) based on experimental data is given. For the systems with concentration dependent mass-transfer and distribution coefficients a method dividing the length of fibers into segments with the same inlet to outlet concentration difference in the feed phase is suggested. The mean values of mass-transfer and distribution coefficients are estimated for each segment independently. For the tested system with BA, convergence of the simulation results was achieved for more than 20 segments. Dependences of the total number of contactors (length of fibers) on the shell Reynolds number and approach to the equilibrium at the raffinate end of the HF contactor exhibit a minimum at about 0.9 and 0.40, respectively. The overall number of contactors in MBSE and MBSS is very sensitive to the increase in BA yield in MBSE above 0.85. For following process parameters: volumetric flow rate 1 m(3) h(-1), feed concentration 350 mol m(-3), yield of BA in MBSE 85%, Re-shell =0-9, approach to equilibrium at the raffinate end of the HF contactor 0.40, and concentration factor of 10, the number of contactors of Liqui-Cel type 10 in. x 28 in. (Celgard) in series, without parallel lines of contactors, is five in MBSE and eight in stripping. In case when two parallel lines of contactors are used the number of contactors in series is two in extraction and four in stripping. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:275 / 287
页数:13
相关论文
共 50 条
  • [21] Membrane-based solvent extraction of aroma compounds: Choice of configurations of hollow fiber modules based on experiments and simulation
    Bocquet, S.
    Gascons Viladomat, E.
    Muvdi Nova, C.
    Sanchez, J.
    Athes, V.
    Souchon, I.
    JOURNAL OF MEMBRANE SCIENCE, 2006, 281 (1-2) : 358 - 368
  • [22] Membrane-based extraction joined with membrane-based stripping in a circulating arrangement II.: Extraction of organic acids
    Vajda, M
    Sabolová, E
    Schlosser, S
    Mikulová, E
    CHEMICAL PAPERS, 2003, 57 (01) : 3 - 10
  • [23] Performance Evaluation of Hollow Fiber Membrane Contactors for Dispersion-Free Extraction of Cu2+ through Modelling and Simulation
    Muhammad, Amir
    Ali, Wajid
    Ahmad, Iftikhar
    Younas, Mohammad
    PERIODICA POLYTECHNICA-CHEMICAL ENGINEERING, 2017, 61 (02) : 133 - 143
  • [24] Membrane-based solvent extraction and stripping of zinc in a hollow-fibre contactor operating in a circulating mode
    Vajda, M
    Havalda, I
    Mácek, R
    DESALINATION, 2004, 163 (1-3) : 19 - 25
  • [25] Two-dimensional simulation of hollow fiber membrane fabricated by phase inversion method
    Yang, Xiao-Tian
    Xu, Zhen-Liang
    Wei, Yong-Ming
    Journal of Applied Polymer Science, 2006, 100 (03): : 2067 - 2074
  • [26] Composite hollow fiber membranes for organic solvent-based liquid-liquid extraction
    He, T
    Versteeg, LAM
    Mulder, MHV
    Wessling, M
    JOURNAL OF MEMBRANE SCIENCE, 2004, 234 (1-2) : 1 - 10
  • [27] Two-dimensional simulation of hollow fiber membrane fabricated by phase inversion method
    Yang, XT
    Xu, ZL
    Wei, YM
    JOURNAL OF APPLIED POLYMER SCIENCE, 2006, 100 (03) : 2067 - 2074
  • [28] EXTRACTION OF MONOCARBOXYLIC ACIDS AND ORGANIC-BASES IN 3-PHASE WATER POLAR-SOLVENT NONPOLAR SOLVENT SYSTEMS
    PYATNITSKII, IV
    FRANKOVSKII, VA
    YURCHENKO, VV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1983, 38 (10): : 1356 - 1359
  • [29] Single-stage and two-stage solvent extraction of Tl(III) in hollow-fiber contactors under recirculation mode of operation
    Trtic, TM
    Vladisavljevic, GT
    Comor, JJ
    SEPARATION SCIENCE AND TECHNOLOGY, 2001, 36 (02) : 295 - 312
  • [30] Automated hollow fiber microextraction based on two immiscible organic solvents for the extraction of two hormonal drugs
    Tajik, Mohammad
    Yamini, Yadollah
    Esrafili, Ali
    Ebrahimpour, Behnam
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 107 : 24 - 31