Does cochlear nerve size affect postoperative hearing performance in pediatric patients with cochlear implants and normal cochlear nerves?

被引:0
|
作者
Gozen, Emine Deniz [1 ]
Yener, H. Murat [1 ]
Kara, Halide [2 ]
Atas, Ahmet [2 ]
Kizilkilic, Osman [3 ]
Cansiz, Harun [1 ]
机构
[1] Istanbul Univ Cerrahpasa, Otorhinolaryngol Dept, Med Fac, Istanbul, Turkey
[2] Istanbul Univ, Fac Hlth Sci, Audiol Dept, Istanbul, Turkey
[3] Istanbul Univ Cerrahpasa, Radiodiagnost Dept, Med Fac, Istanbul, Turkey
关键词
Cochlear implantation; Prelingual deafness; Cochlear nerve morphology; Auditory perception; LANGUAGE-DEVELOPMENT; SPOKEN LANGUAGE; INNER-EAR; CHILDREN; OUTCOMES; SPEECH; PERCEPTION; DIAMETER; APLASIA;
D O I
10.1016/j.bjorl.2020.06.019
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Introduction: Cochlear implantation is an effective treatment method for severe to profound hearing loss. Many factors that may influence cochlear implantation success have been explained in previous studies. Apart from those, minor differences in size of normal cochlear nerves may affect postoperative performance. Objective: To investigate whether the minor differences in cochlear nerve size in normal cochlear nerves affect postoperative cochlear implant performance. Methods: 30 pediatric prelingually deaf patients who were treated with cochlear implantation were included in this study. From the reconstructed parasagittal magnetic resonance images, the diameter and cross-sectional area of the cochlear nerve on the ipsilateral and contralateral side were measured. Auditory evaluations were performed 1, 3, 6 and 12 months following the first fitting. All the analysis was performed by using EARS (R), evaluation of auditory responses to speech tool. Correlation between cochlear nerve diameter, cross-sectional area and postoperative auditory perception was analyzed to determine whether variation in cochlear nerve size contributes to postoperative auditory performance. Results: The mean diameter of the cochlear nerve on the ipsilateral side was 718.4 mu m (504.5-904.3 mu m) and mean cross sectional area was 0.015 cm(2) (0.012-0.018 cm(2)). On the contralateral side the mean cochlear nerve diameter was 714.4 mu m (502.6-951.4 mu m) and mean cross sectional area was 0.014 cm(2) (0.011-0.019 cm(2)). The correlation between the diameter and cross-sectional area of the ipsilateral and contralateral cochlear nerve revealed no significance. Mean score at first month monosyllable-trochee-polysyllable test, MTP1, was 0.17 (0.08-0.33), at 6th month with 6 words test, 6th month MTP6 was 0.72 (0.39-1.0), at 6th month with 12 words, 6th month MTP 12 was 0.46 (0.17-0.75) and at 12th month with 12 words, 12th month MTP12 was 0.73 (0.25-1.0). There was no correlation between the monosyllable-trochee-polysyllable test, values at any time with the diameter of the ipsilateral cochlear nerve. However, the first month MTP, 6th month MTP6 and 12th month MTP12 correlated with the cross-sectional area of the ipsilateral cochlear nerve. Conclusion: Measuring the cross sectional area of the normal appearing cochlear nerve may give important prognostic knowledge on cochlear implant outcomes. In patients with a larger cross sectional area the auditory performance was better and faster. Although normal appearing, slight differences on cross sectional area of the cochlear nerve may affect performance. Measuring the size of the cochlear nerve on parasagittal magnetic resonance images may provide beneficial information on the postoperative rehabilitation process.
引用
收藏
页码:390 / 398
页数:9
相关论文
共 50 条
  • [21] Does Cochlear Nerve Size Differ Among Societies?
    Imamoglu, Hakan
    Erkoc, Mustafa Fatih
    Dogan, Mansur
    Durmus, Kasim
    Mavili, Ertugrul
    Vurdem, Umit Erkan
    Aydemir, Eylem Itir
    ERCIYES MEDICAL JOURNAL, 2015, 37 (01) : 16 - 18
  • [22] Binaural Pitch Fusion in Children With Normal Hearing, Hearing Aids, and Cochlear Implants
    Hartling, Curtis L.
    Fowler, Jennifer R.
    Stark, Gemaine N.
    Glickman, Bess
    Eddolls, Morgan
    Oh, Yonghee
    Ramsey, Katrina
    Reiss, Lina A. J.
    EAR AND HEARING, 2020, 41 (06): : 1545 - 1559
  • [23] Overimitation of Children With Cochlear Implants or Hearing Aids in Comparison With Children With Normal Hearing
    Wang, Zhidan
    Zhu, Xiaoyu
    Fong, Frankie T. K.
    Meng, Jing
    Wang, Haijing
    INFANTS & YOUNG CHILDREN, 2020, 33 (01): : 84 - 92
  • [24] SPEECH PERFORMANCE BY PATIENTS WITH MULTICHANNEL COCHLEAR IMPLANTS
    PARKIN, JL
    DANKOWSKI, MK
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1986, 95 (02) : 205 - 209
  • [25] Timbre recognition in Danish children with hearing aids, cochlear implants or normal hearing
    Kepp, Nille Elise
    Schioth, Christina
    Percy-Smith, Lone
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2022, 159
  • [26] Guidelines for the performance of MRI in patients with cochlear implants
    Dubrulle, F.
    Vincent, C.
    Varoquaux, A.
    Ernst, O.
    Veillon, F.
    JOURNAL DE RADIOLOGIE, 2011, 92 (10): : 872 - 877
  • [27] Hearing performance of cochlear implant patients in noise
    Hamzavi, J
    Baumgartner, WD
    Gstoettner, W
    UPDATES IN COCHLEAR IMPLANTATION, 2000, 57 : 320 - 322
  • [28] Spatial Acuity in 2-to-3-Year-Old Children With Normal Acoustic Hearing, Unilateral Cochlear Implants, and Bilateral Cochlear Implants
    Grieco-Calub, Tina M.
    Litovsky, Ruth Y.
    EAR AND HEARING, 2012, 33 (05): : 561 - 572
  • [29] Language skills and phonological awareness in children with cochlear implants and normal hearing
    Soleymani, Zahra
    Mahmoodabadi, Najmeh
    Nouri, Mina Mohammadi
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2016, 83 (04) : 16 - 21
  • [30] Mandarin tone recognition in English speakers with normal hearing and with cochlear implants
    Nie, Kaibao
    Hannaford, Sophia
    Director, Hannah M.
    Nishigaki, Micah A.
    Drennan, Ward R.
    Rubinstein, Jay T.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2019, 58 (12) : 913 - 922