Chromatography columns packed with thermoresponsive-cationic-polymer-modified beads for therapeutic drug monitoring

被引:9
|
作者
Nagase, Kenichi [1 ]
Takagi, Hikaru [1 ]
Nakada, Hideo [1 ,2 ]
Ishikawa, Haruki [1 ,2 ]
Nagata, Yoshiko [1 ]
Aomori, Tohru [1 ,2 ]
Kanazawa, Hideko [1 ]
机构
[1] Keio Univ, Fac Pharm, Minato Ku, 1-5-30 Shibakoen, Tokyo 1058512, Japan
[2] Keio Univ Hosp, Dept Pharm, Shinjuku Ku, 35 Shinanomachi, Tokyo 1608582, Japan
基金
日本学术振兴会; 日本科学技术振兴机构;
关键词
TEMPERATURE-RESPONSIVE CHROMATOGRAPHY; COPOLYMER BRUSH SURFACES; MONOLITHIC SILICA RODS; HIGH-SPEED SEPARATION; BASIC BIOMOLECULES; LIPOSOMES; MICELLES; CELLS;
D O I
10.1038/s41598-022-16928-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Therapeutic drug monitoring, which is used to determine appropriate drug doses, is critical in pharmacological therapy. In this study, we developed thermoresponsive chromatography columns with various cationic properties for effective therapeutic drug monitoring. Thermoresponsive cationic copolymer poly(N-isopropylacrylamide-co-n-butyl methacrylate-co-N,N-dimethylaminopropyl acrylamide) (P(NIPAAm-co-BMA-co-DMAPAAm))-modified silica beads, which were used as the chromatographic stationary phase, were prepared by modifying the radical initiator of the silica beads, followed by radical polymerization. Characterization of the prepared silica beads demonstrated that thermoresponsive polymers with various cationic properties successfully modified the beads. The elution behavior of several steroids in the prepared bead-packed columns at various temperatures indicated that the optimal column operating temperature was 30 degrees C. Appropriate measurement conditions for 13 drugs were investigated by varying the cationic properties of the columns and the pH of the mobile phase. Drug concentrations in serum samples were determined using the developed columns and mobile phases with a suitable pH. Voriconazole concentrations in human serum samples were determined using the developed columns with all-aqueous mobile phases. We anticipate that the developed chromatography columns can be used for therapeutic drug monitoring because drug concentrations can be measured using all-aqueous mobile phases that are suitable in clinical settings.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] High-Performance Liquid Chromatography for Therapeutic Drug Monitoring of Serum Lenvatinib
    Watanabe, Yusuke
    Doki, Kosuke
    Sekine, Ikuo
    Hara, Hisato
    Homma, Masato
    THERAPEUTIC DRUG MONITORING, 2020, 42 (04) : 554 - 558
  • [32] Microemulsions and nanoemulsions modified with cationic surfactants for improving the solubility and therapeutic efficacy of loaded drug indomethacin
    Mirgorodskaya, Alla B.
    Koroleva, Marina Yu
    Kushnazarova, Rushana A.
    Mishchenko, Ekaterina, V
    Petrov, Konstantin A.
    Lenina, Oxana A.
    Vyshtakalyuk, Alexandra B.
    Voloshina, Alexandra D.
    Zakharova, Lucia Ya
    NANOTECHNOLOGY, 2022, 33 (15)
  • [33] Designable size exclusion chromatography columns based on dendritic polymer-modified porous silica particles
    Sakai, K
    Teng, TC
    Katada, A
    Harada, T
    Yoshida, K
    Yamanaka, K
    Asami, Y
    Sakata, M
    Hirayama, C
    Kunitake, M
    CHEMISTRY OF MATERIALS, 2003, 15 (21) : 4091 - 4097
  • [34] Short metal capillary columns packed with polymer0coated fibrous materials in high-temperature gas chromatography
    Saito, Y
    Ogawa, M
    Imaizumi, M
    Ban, K
    Abe, A
    Takeichi, T
    Wada, H
    Jinno, K
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2005, 43 (10) : 536 - 541
  • [35] Gas chromatography-mass spectrometry assay method for the therapeutic drug monitoring of the antiepileptic drug tiagabine
    Chollet, DF
    Castella, E
    Goumaz, L
    Anderegg, G
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (03) : 641 - 646
  • [36] Synthesis and characterisation of cationic quaternary ammonium-modified polyvinyl alcohol hydrogel beads as a drug delivery embolisation system
    Heaysman, Clare L.
    Phillips, Gary J.
    Lloyd, Andrew W.
    Lewis, Andrew L.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2016, 27 (03) : 1 - 10
  • [37] Temperature-responsive molecular recognition chromatography using phenylalanine and tryptophan derived polymer modified silica beads
    Hiruta, Yuki
    Kanazashi, Ryosuke
    Ayano, Eri
    Okano, Teruo
    Kanazawa, Hideko
    ANALYST, 2016, 141 (03) : 910 - 917
  • [38] ONLINE SUPERCRITICAL FLUID EXTRACTION AND CHROMATOGRAPHY OF ORGANOTINS WITH PACKED MICROBORE COLUMNS AND FORMIC-ACID MODIFIED CARBON-DIOXIDE
    OUDSEMA, JW
    POOLE, CF
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (10-11): : 426 - 434
  • [39] Synthesis and characterisation of cationic quaternary ammonium-modified polyvinyl alcohol hydrogel beads as a drug delivery embolisation system
    Clare L. Heaysman
    Gary J. Phillips
    Andrew W. Lloyd
    Andrew L. Lewis
    Journal of Materials Science: Materials in Medicine, 2016, 27
  • [40] High-performance liquid chromatography with ultraviolet detection for therapeutic drug monitoring of everolimus
    Baldelli, S
    Murgia, S
    Merlini, S
    Zenoni, S
    Perico, N
    Remuzzi, G
    Cattaneo, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 99 - 105