Tibial Interference Screw Positioning Relative to the Bone Plug in ACL Reconstruction: A Biomechanical Comparison of Cortical Versus Cancellous-Sided Placement

被引:4
|
作者
Marsh, Nathan A. [1 ]
Antosh, Ivan J. [2 ]
O'Conor, Daniel K. [3 ]
Ortega, Raymond J. [3 ]
Paneral, Nicholas S. [3 ]
Cameron, Kenneth L. [4 ]
Posner, Matthew [3 ,4 ]
机构
[1] Womack Army Med Ctr, Ft Bragg, NC USA
[2] Dwight D Eisenhower Army Med Ctr, 300 E Hosp Rd, Ft Gordon, GA 30905 USA
[3] US Mil Acad, Dept Mech Engn, West Point, NY USA
[4] Keller Army Community Hosp, John A Feagin Jr Orthopaed Sports Med Fellowship, West Point, NY USA
关键词
ANTERIOR CRUCIATE LIGAMENT; GRAFT FIXATION DEVICES; TUNNEL MISMATCH; PATELLAR;
D O I
10.3928/01477447-20180815-03
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The biomechanical strength of a bone-patellar tendon-bone graft in the tibia may vary depending on whether the interference screw abuts the cancellous vs the cortical surface of the bone plug. In a porcine model 10x20-mm bone-patellar tendon-bone grafts were prepared and fixed in a 10-mm diameter tibial tunnel using a 9x25-mm titanium interference screw. the screw was positioned on the cancellous surface of the graft in group A vs the cortical side of the graft in group B (n=14). Specimens underwent precycling cyclic loading and load-to-failure testing. The mean ultimate failure load was 493 +/- 245 N for group A vs 304 +/- 145 N for group B (P=.008). Sixty-nine percent of specimens in group A survived 1000 cycles of load testing compared with 21% of specimens in group 13. Forty-three percent of specimens in group B sustained intratendinous failure adjacent to the bone plug compared with 15% of specimens in group A. Orientation of the tibial interference screw along the cancellous vs the cortical side of the graft results in superior cyclic loading and ultimate failure load characteristics. Additionally screw placement along the cortical side may weaken the tendon interface and lead to tendon failure under load. This study indicates that placement of the tibial interference screw along the cancellous side of the graft is biomechanically favorable. However the clinical ramifications of these findings are not clear.
引用
收藏
页码:337 / 342
页数:6
相关论文
共 33 条
  • [21] Short and proximalized interference screw fixation leads to tibial tunnel bone re-growth and better hamstring graft integration in ACL reconstruction
    Simon-Sanchez, Francisco J.
    Perelli, Simone
    Pizza, Nicola
    Delmedico, Michelangelo
    Morales-Avalos, Rodolfo
    Claramunt, Raul Torres
    Monllau, Joan C.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024,
  • [22] Biomechanical comparison of Tibial-sided supplemental fixation techniques in Bone-Patellar Tendon-Bone anterior cruciate ligament reconstruction
    Hurwit, Daniel J.
    Habet, Nahir A.
    Meade, Joshua D.
    Berk, Alexander N.
    Young, Bradley L.
    Odum, Susan
    Wang, Schangcheng
    Schallmo, Michael S.
    Fleischli, James E.
    Trofa, David P.
    Saltzman, Bryan M.
    KNEE, 2023, 41 : 66 - 71
  • [23] Reverse Anterior Cruciate Ligament Reconstruction Fixation: A Biomechanical Comparison Study of Tibial Cross-Pin and Femoral Interference Screw Fixation
    Lawley, Richard J.
    Klein, Samuel E.
    Chudik, Steven C.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (03): : 625 - 632
  • [24] RETRACTED: Biodegradable screw versus a press-fit bone plug fixation for ACL reconstruction. A prospective randomized study (Retracted Article)
    Geiges, B.
    von Falck, C.
    Knobloch, K.
    Haasper, C.
    Meller, R.
    Krettek, C.
    Hankemeier, S.
    Brand, J.
    Jagodzinski, M.
    UNFALLCHIRURG, 2013, 116 (02): : 109 - 117
  • [25] Biomechanical Comparison of 2 Anterior Cruciate Ligament Graft Preparation Techniques for Tibial Fixation: Adjustable-Length Loop Cortical Button or Interference Screw
    Mayr, Raul
    Heinrichs, Christian Heinz
    Eichinger, Martin
    Coppola, Christian
    Schmoelz, Werner
    Attal, Rene
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (06): : 1380 - 1385
  • [26] Adjustable-length loop cortical button versus interference screw fixation in quadriceps tendon anterior cruciate ligament reconstruction - A biomechanical in vitro study
    Karkosch, Roman Frederik
    Ettinger, Max
    Bachmaier, Samuel
    Wijdicks, Coen A.
    Smitha, Tomas
    CLINICAL BIOMECHANICS, 2018, 60 : 60 - 65
  • [27] A Comparison of Two-Year Anterior Cruciate Ligament Reconstruction Clinical Outcomes Using All-Soft Tissue Quadriceps Tendon Autograft With Femoral/Tibial Cortical Suspensory Fixation Versus Tibial Interference Screw Fixation
    Greif, Dylan N.
    Shallop, Brandon J.
    Allegra, Paul R.
    Cade, William H., II
    Minesinger, Kayla E.
    Luxenburg, Dylan
    Kaplan, Lee D.
    Baraga, Michael G.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2022, 38 (03): : 881 - 891
  • [28] Biomechanical Evaluation of Cross-Pin Versus Interference Screw Tibial Fixation Using a Soft-Tissue Graft During Transtibial Posterior Cruciate Ligament Reconstruction
    Lee, Yong Seuk
    Wang, Joon Ho
    Bae, Ji Hoon
    Lim, Hong Chul
    Park, Jung Ho
    Ahn, Jin Hwan
    Bae, Tae Soo
    Lim, Bee-Oh
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (09): : 989 - 995
  • [29] Adjustable-Loop Femoral Cortical Suspensory Fixation for Patellar Tendon Anterior Cruciate Ligament Reconstruction A Time Zero Biomechanical Comparison With Interference Screw Fixation
    Mickelson, Dayne T.
    Lefebvre, Thomas
    Gall, Ken
    Riboh, Jonathan C.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2018, 46 (08): : 1857 - 1862
  • [30] Biomechanical Comparison of Epiphyseal Anterior Cruciate Ligament Fixation Using a Cortical Button Construct Versus an Interference Screw and Sheath Construct in Skeletally Immature Cadaveric Specimens
    Dukas, Alex G.
    Shea, Kevin G.
    Nissen, Carl W.
    Obopilwe, Elifho
    Fabricant, Peter D.
    Cannamela, Peter C.
    Milewski, Matthew D.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (06):