Tibial Interference Screw Positioning Relative to the Bone Plug in ACL Reconstruction: A Biomechanical Comparison of Cortical Versus Cancellous-Sided Placement

被引:4
|
作者
Marsh, Nathan A. [1 ]
Antosh, Ivan J. [2 ]
O'Conor, Daniel K. [3 ]
Ortega, Raymond J. [3 ]
Paneral, Nicholas S. [3 ]
Cameron, Kenneth L. [4 ]
Posner, Matthew [3 ,4 ]
机构
[1] Womack Army Med Ctr, Ft Bragg, NC USA
[2] Dwight D Eisenhower Army Med Ctr, 300 E Hosp Rd, Ft Gordon, GA 30905 USA
[3] US Mil Acad, Dept Mech Engn, West Point, NY USA
[4] Keller Army Community Hosp, John A Feagin Jr Orthopaed Sports Med Fellowship, West Point, NY USA
关键词
ANTERIOR CRUCIATE LIGAMENT; GRAFT FIXATION DEVICES; TUNNEL MISMATCH; PATELLAR;
D O I
10.3928/01477447-20180815-03
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The biomechanical strength of a bone-patellar tendon-bone graft in the tibia may vary depending on whether the interference screw abuts the cancellous vs the cortical surface of the bone plug. In a porcine model 10x20-mm bone-patellar tendon-bone grafts were prepared and fixed in a 10-mm diameter tibial tunnel using a 9x25-mm titanium interference screw. the screw was positioned on the cancellous surface of the graft in group A vs the cortical side of the graft in group B (n=14). Specimens underwent precycling cyclic loading and load-to-failure testing. The mean ultimate failure load was 493 +/- 245 N for group A vs 304 +/- 145 N for group B (P=.008). Sixty-nine percent of specimens in group A survived 1000 cycles of load testing compared with 21% of specimens in group 13. Forty-three percent of specimens in group B sustained intratendinous failure adjacent to the bone plug compared with 15% of specimens in group A. Orientation of the tibial interference screw along the cancellous vs the cortical side of the graft results in superior cyclic loading and ultimate failure load characteristics. Additionally screw placement along the cortical side may weaken the tendon interface and lead to tendon failure under load. This study indicates that placement of the tibial interference screw along the cancellous side of the graft is biomechanically favorable. However the clinical ramifications of these findings are not clear.
引用
收藏
页码:337 / 342
页数:6
相关论文
共 33 条
  • [1] Biomechanical Comparison of a Novel Tibial Fixation Technique Versus Interference Screw Fixation for ACL Reconstruction Using Soft Tissue Grafts
    Sun, Tinghan
    Zhang, Hangzhou
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (08)
  • [2] BIOMECHANICAL PERFORMANCE OF METALLIC AND BIOABSORBABLE INTERFERENCE SCREW FOR TIBIAL GRAFT FIXATION IN ACL RECONSTRUCTION
    Ocampo More, Ari Digiacomo
    Almeida Pizzolatti, Andre Luiz
    Fancello, Eduardo
    de Mello Roesler, Carlos Rodrigo
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [3] Comparison between a novel human cortical bone screw and bioabsorbable interference screw for graft fixation of ACL reconstruction
    Shen, X. -Z.
    Qu, F.
    Li, C. -B.
    Qi, W.
    Lu, X.
    Li, H. -L.
    Guo, Q.
    Wang, J. -T.
    Zhao, G.
    Liu, Y. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 : 111 - 118
  • [4] Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods
    Christian Carulli
    Fabrizio Matassi
    Stefano Soderi
    Luigi Sirleo
    Giovanni Munz
    Massimo Innocenti
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 1264 - 1271
  • [5] Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods
    Carulli, Christian
    Matassi, Fabrizio
    Soderi, Stefano
    Sirleo, Luigi
    Munz, Giovanni
    Innocenti, Massimo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (04) : 1264 - 1271
  • [6] RADIOGRAPHIC ANALYSIS OF FEMORAL INTERFERENCE SCREW PLACEMENT DURING ACL RECONSTRUCTION - ENDOSCOPIC VERSUS OPEN TECHNIQUE
    LEMOS, MJ
    ALBERT, J
    SIMON, T
    JACKSON, DW
    ARTHROSCOPY, 1993, 9 (02): : 154 - 158
  • [7] Mechanical Evaluation of Bone-Patellar Tendon-Bone Graft Fixation to the Tibia in ACL Reconstruction: Bone Plug Tensioning and Fixation System versus Interference Screw
    Iuchi, Ryo
    Shino, Konsei
    Mae, Tatsuo
    Yamakawa, Satoshi
    Nakata, Ken
    JOURNAL OF KNEE SURGERY, 2024, 37 (13) : 894 - 901
  • [8] Significant Loss of ACL Graft Force With Tibial-Sided Soft Tissue Interference Screw Fixation Over 24 Hours: A Biomechanical Study
    Kruppa, Philipp
    Flies, Anne
    Wulsten, Dag
    Collette, Robert
    Duda, Georg N.
    Schaser, Klaus-Dieter
    Becker, Roland
    Kopf, Sebastian
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (05)
  • [9] Biomechanical evaluation of a medial knee reconstruction with comparison of bioabsorbable interference screw constructs and optimization with a cortical button
    Wijdicks, Coen A.
    Brand, Emily J.
    Nuckley, David J.
    Johansen, Steinar
    LaPrade, Robert F.
    Engebretsen, Lars
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (11) : 1532 - 1541
  • [10] Biomechanical evaluation of a medial knee reconstruction with comparison of bioabsorbable interference screw constructs and optimization with a cortical button
    Coen A. Wijdicks
    Emily J. Brand
    David J. Nuckley
    Steinar Johansen
    Robert F. LaPrade
    Lars Engebretsen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 1532 - 1541