Dual contrast enhanced magnetic resonance imaging of the liver with superparamagnetic iron oxide followed by gadolinium for lesion detection and characterization

被引:37
|
作者
Kubaska, S [1 ]
Sahani, DV [1 ]
Saini, S [1 ]
Hahn, PF [1 ]
Halpern, E [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Abdominal Imaging & Intervent, Boston, MA 02114 USA
关键词
iron oxide; gadolinium; liver; MRI; signal intensity;
D O I
10.1053/crad.2000.0673
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: Iron oxide contrast agents are useful for lesion detection, and extracellular gadolinium chelates are advocated for lesion characterization. We undertook a study to determine if dual contrast enhanced liver imaging with sequential use of ferumoxides particles and gadolinium (Gd)-DTPA can be performed in the same imaging protocol. MATERIALS AND METHODS: Sixteen patients underwent dual contrast magnetic resonance imaging (MRT) of the liver for evaluation of known/suspected focal lesions which included, metastases (n = 5), hepatocellular carcinoma (HCC; n = 3), cholangiocharcinoma (n = 1) and focal nodular hyperplasia (FNH; n = 3). Pre- and post-iron oxide T1-weighted gradient recalled echo (GRE) and T2-weighted fast spin echo (FSE) sequences were obtained, followed by post-Gd-DTPA (0.1 mmol/kg) multi-phase dynamic T1-weighted out-of-phase GRE imaging. Images were analysed in a blinded fashion by three experts using a three-point scoring system for lesion conspicuity on pre- and post-iron oxide T1 images as well as for reader's confidence in characterizing liver lesions on post Gd-DTPA T1 images. RESULTS: No statistically significant difference in lesion conspicuity was observed on pre- and post-iron oxide T1-GRE images in this small study cohort. The presence of iron oxide did not appreciably diminish image quality of post-gadolinium sequences and did not prevent characterization of liver lesions. CONCLUSION: Our results suggest that characterization of focal liver lesion with Gd-enhanced liver MRI is still possible following iron oxide enhanced imaging. Radiology, 56, 410-415 (C) 2001 The Royal College of Radiology.
引用
收藏
页码:410 / 415
页数:6
相关论文
共 50 条
  • [41] Hepatocellular lesions with increased iron uptake on superparamagnetic iron oxide-enhanced magnetic resonance imaging in cirrhosis or chronic hepatitis: comparison of four magnetic resonance sequences for lesion conspicuity
    Tanabe, Masahiro
    Ito, Katsuyoshi
    Shimizu, Ayame
    Fujita, Takeshi
    Onoda, Hideko
    Yamatogi, Shigenari
    Washida, Yasuo
    Matsunaga, Naofumi
    MAGNETIC RESONANCE IMAGING, 2009, 27 (06) : 801 - 806
  • [42] Superparamagnetic iron oxide-enhanced versus gadolinium-enhanced MR imaging for differential diagnosis of focal liver lesions
    Vogl, TJ
    Hammerstingl, R
    Schwarz, W
    Mack, MG
    Muller, PK
    Pegios, W
    Keck, H
    EiblEibesfeldt, A
    Hoelzl, J
    Woessmer, B
    Bergman, C
    Felix, R
    RADIOLOGY, 1996, 198 (03) : 881 - 887
  • [43] Ultrasmall Superparamagnetic Iron Oxide Nanoparticles as Nanocarriers for Magnetic Resonance Imaging: Development and In Vivo Characterization
    Si, Ge
    Hapuarachchige, Sudath
    Artemov, Dmitri
    ACS APPLIED NANO MATERIALS, 2022, 5 (07) : 9625 - 9632
  • [44] MAGNETIC-RESONANCE-IMAGING WITH SUPERPARAMAGNETIC IRON-OXIDE PARTICLES FOR THE DETECTION OF MYOCARDIAL REPERFUSION
    ROZENMAN, Y
    ZOU, XM
    KANTOR, HL
    MAGNETIC RESONANCE IMAGING, 1991, 9 (06) : 933 - 939
  • [45] Integration of gadolinium in nanostructure for contrast enhanced-magnetic resonance imaging
    Marasini, Ramesh
    Tuyen Duong Thanh Nguyen
    Aryal, Santosh
    WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY, 2020, 12 (01)
  • [46] The feasibility of superparamagnetic iron oxide-enhanced magnetic resonance imaging for assessing liver lesions in patients with contraindications for iodine CT contrast media or gadolinium-based MR contrast media: a retrospective case-control study
    Kurata, Chishio
    Saito, Kazuhiro
    Shirota, Natsuhiko
    Araki, Yoichi
    Sugimoto, Katsutoshi
    Tajima, Yu
    Yunaiyama, Daisuke
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, : 4612 - 4621
  • [47] Phase characteristic of superparamagnetic iron oxide particles in magnetic resonance imaging
    Zhu, Haitao
    Demachi, Kazuyuki
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2010, 33 (1-2) : 721 - 726
  • [48] Phase Characteristic of Superparamagnetic Iron Oxide Particles in Magnetic Resonance Imaging
    Zhu, Haitao
    Demachi, Kazuyuki
    APPLIED ELECTROMAGNETICS AND MECHANICS (II), 2009, 13 : 283 - 284
  • [49] Monomer-coated very small superparamagnetic iron oxide particles as contrast medium for magnetic resonance imaging - Preclinical in vivo characterization
    Wagner, S
    Schnorr, J
    Pilgrimm, H
    Hamm, B
    Taupitz, M
    INVESTIGATIVE RADIOLOGY, 2002, 37 (04) : 167 - 177
  • [50] Superparamagnetic Iron Oxide-Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain
    Thorek, Daniel L. J.
    Weisshaar, Christine L.
    Czupryna, Julie C.
    Winkelstein, Beth A.
    Tsourkas, Andrew
    MOLECULAR IMAGING, 2011, 10 (03) : 206 - 214