Highly Sensitive Ratiometric Fluorescent Detection of Indium(III) Using Fluorescent Probe Based on Phosphoserine as a Receptor

被引:37
|
作者
Mehta, Pramod Kumar [1 ]
Hwang, Gi Won [1 ]
Park, Joohee [1 ]
Lee, Keun-Hyeung [1 ]
机构
[1] Inha Univ, Ctr Design & Applicat Mol Catalysts, Dept Chem & Chem Engn, Incheon 402751, South Korea
基金
新加坡国家研究基金会;
关键词
AGGREGATION-INDUCED EMISSION; HEAVY-METAL IONS; LIQUID-CHROMATOGRAPHY; AMINO-ACIDS; BINDING; CELLS; SPECTROMETRY; CHEMOSENSOR; SELECTIVITY; EXTRACTION;
D O I
10.1021/acs.analchem.8b01440
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Indium is one of the most widely used scarce metals for manufacturing various electronic devices including notebooks, mobile phones, and PC monitors. Recent studies revealed that indium and its compound could cause several soo toxicities to human beings and animals. However, there is no report about ratiometric fluorescent detection of In(III) in aqueous solutions. We synthesized a fluorescent probe (1) for In(III) based on a phosphoserine as a receptor with a pyrene fluorophore using solid phase synthesis. 1 showed highly sensitive ratiometric response to In(III) in purely aqueous solutions by increasing excimer emission intensity at 476 nm with a concomitant decrease in monomer emission intensity at 395 nm. 1 showed sensitive ratiometric responses to In(III) over a wide range of pH (2 < pH < 8) and exhibited a highly selective ratiometric response to In(III) among 18 tested metal including Al(III) and Ga(III). Job's plot analysis indicated that 1 preferred to form a 2:1 complex with In(III) and the binding affinity for In(III) was measured to be 2.3 X 10(12) M-2 (R-2 = 0.989). 1 showed linear ratiometric responses to nanomolar concentrations (0-750 nM) of In(III) and the detection limit was calculated to be 64 nM (R-2 = 0.992) in aqueous solution. The binding mode study using NMR, IR, and CD spectroscopies revealed that the phosphate and the amide groups of the receptor of 1 played an important role for the binding with In(III). Moreover, 1 was suitable for the ratiometric detection of In(III) in tap water and groundwater. 1 showed much better detection properties than those of the colorimetric methods using EDTA with Eriochrome black T (EBT) and 4-(2-pyridylazo) resorcinol (PAR) for the detection of In(III) in tap water and groundwater.
引用
收藏
页码:11256 / 11264
页数:9
相关论文
共 50 条
  • [41] A FRET based ratiometric fluorescent probe for detection of sulfite in food
    Zhang, Gongxiao
    Ji, Ruixue
    Kong, Xiangyu
    Ning, Fujiao
    Liu, Aikun
    Cui, Jichun
    Ge, Yanqing
    RSC ADVANCES, 2019, 9 (02) : 1147 - 1150
  • [42] Reversible ratiometric detection of highly reactive hydropersulfides using a FRET-based dual emission fluorescent probe
    Kawagoe, Ryosuke
    Takashima, Ippei
    Uchinomiya, Shohei
    Ojida, Akio
    CHEMICAL SCIENCE, 2017, 8 (02) : 1134 - 1140
  • [43] A ratiometric fluorescent probe for fast and sensitive detection of peroxynitrite: a boronate ester as the receptor to initiate a cascade reaction
    Zhou, Ji
    Li, Yang
    Shen, Jiaoning
    Li, Qiang
    Wang, Rui
    Xu, Yufang
    Qian, Xuhong
    RSC ADVANCES, 2014, 4 (93) : 51589 - 51592
  • [44] A Highly Sensitive and Selective Fluorescent Probe for the Detection of Cerium(III) Using Tridentate Based-Oxazolidine: Experimental and DFT Investigations
    Promkatkaew, Malinee
    Chuaitammakit, Laksamee Chaicharoenwimolkul
    Naree, Kitiya
    Sillapa, Jinnapus
    Kongsriprapan, Sopanat
    JOURNAL OF FLUORESCENCE, 2023, 33 (01) : 145 - 152
  • [45] A Highly Sensitive and Selective Fluorescent Probe for the Detection of Cerium(III) Using Tridentate Based-Oxazolidine: Experimental and DFT Investigations
    Malinee Promkatkaew
    Laksamee Chaicharoenwimolkul Chuaitammakit
    Kitiya Naree
    Jinnapus Sillapa
    Sopanat Kongsriprapan
    Journal of Fluorescence, 2023, 33 : 145 - 152
  • [46] The quinoline derivative of ratiometric and sensitive fluorescent zinc probe based on deprotonation
    Du, Jianjun
    Fan, Jiangli
    Peng, Xiaojun
    Li, Honglin
    Sun, Shiguo
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (01) : 337 - 341
  • [47] Branch-Migration Based Fluorescent Probe for Highly Sensitive Detection of Mercury
    Wang, Shanshan
    Lin, Bin
    Chen, Li
    Li, Na
    Xu, Jiaju
    Wang, Jing
    Yang, Yuxiang
    Qi, Yan
    She, Yongxin
    Shen, Xiantao
    Xiao, Xianjin
    ANALYTICAL CHEMISTRY, 2018, 90 (20) : 11764 - 11769
  • [48] A Novel Ratiometric Fluorescent Probe for Detection of Perborate
    Zang Qi-Guang
    Chen Song
    Hou Zhi-Lin
    Li Juan
    Liu You-Nia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (01) : 118 - 122
  • [49] Development of a ratiometric fluorescent probe for the detection of peroxynitrite
    Sun, Ningning
    Cai, Yijin
    Yan, Haijun
    Yang, Wenge
    Hu, Yonghong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 317
  • [50] A new ratiometric fluorescent probe for the detection of thiophenols
    Zhai, Qisong
    Yang, Shengjun
    Fang, Yuli
    Zhang, Haiyan
    Feng, Guoqiang
    RSC ADVANCES, 2015, 5 (114): : 94216 - 94221