SPIRE: The bolometer camera and spectrometer for FIRST

被引:0
|
作者
Gear, WK [1 ]
Griffin, MJ [1 ]
机构
[1] Cardiff Univ, Cardiff CF2 3YB, S Glam, Wales
关键词
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We describe the science goals and outline design for the I SPIRE instrument to be launched on the ESA cornerstone mission FIRST. SPIRE is a bolometer insrtument covering the wavelength range 200-670 microns and will have three imaging channels centred at approximately 250, 350 and 500 microns, along with a broad-band imaging Fourier transform spectrometer operating from 200-670 microns. The photometer will observe the same 4x8 arminute field of view with each channel with diffraction-limited angular resolution (18 arcseconds at 250 microns). The spectrometer will have a field-of-view of at least 2 x 2 arcminutes and will have spectral resolution adjustable from approximately 20 to 1000. The detector arrays will operate at 0.3 K. The primary science gods are deep extragalactic and galactic surveys for high-redshift galaxies and young protostellar sources respectively and follow-up spectrophotometric observations.
引用
收藏
页码:126 / 133
页数:8
相关论文
共 50 条
  • [21] TES Development for a Frequency Selective Bolometer Camera
    Datesman, Aaron M.
    Downes, Thomas P.
    Perera, Thushara A.
    Wang, Gensheng
    Yefremenko, Volodymyr G.
    Pearson, John E.
    Novosad, Valentyn
    Divan, Ralu
    Chang, Clarence L.
    Logan, Daniel W.
    Meyer, Stephan S.
    Wilson, Grant W.
    Bleem, Lindsey E.
    Crites, Abigail T.
    McMahon, Jeffrey J.
    Carlstrom, John E.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 548 - 552
  • [22] A Fourier transform spectrometer for ground testing of the Herschel/SPIRE instrument
    Spencer, LD
    Naylor, DA
    Swinyard, BM
    Aramburu, AA
    Fulton, TR
    Lim, TL
    Ronayette, SD
    Schofield, IS
    OPTICAL, INFRARED, AND MILLIMETER SPACE TELESCOPES, PTS 1-3, 2004, 5487 : 501 - 512
  • [23] Beam profile for the Herschel-SPIRE Fourier transform spectrometer
    Makiwa, Gibion
    Naylor, David A.
    Ferlet, Marc
    Salji, Carl
    Swinyard, Bruce
    Polehampton, Edward
    van der Wiel, Matthijs H. D.
    APPLIED OPTICS, 2013, 52 (16) : 3864 - 3875
  • [24] The Herschel/SPIRE Spectrometer Deglitching/Clipping Tasks and Statistical Analysis
    LeLeu, Guillaume
    Mealier, Anne-Laure
    Benielli, Dominique
    Baluteau, Jean-Paul
    Surace, Christian
    Fulton, Trevor R.
    Imhof, Peter
    Polehampton, Edward
    Vibert, Didier
    ASTRONOMICAL DATA ANALYSIS SOFTWARE AND SYSTEMS XXI, 2012, 461 : 749 - +
  • [25] Performance evaluation of the Herschel/SPIRE imaging Fourier transform spectrometer
    Naylor, David A.
    Baluteau, Jean-Paul
    Davis-Imhof, Peter
    Ferlet, Marc J.
    Fulton, Trevor R.
    Swinyard, Bruce M.
    SPACE TELESCOPES AND INSTRUMENTATION I: OPTICAL, INFRARED, AND MILLIMETER, PTS 1 AND 2, 2006, 6265
  • [26] Observing extended sources with the Herschel SPIRE Fourier Transform Spectrometer
    Wu, R.
    Polehampton, E. T.
    Etxaluze, M.
    Makiwa, G.
    Naylor, D. A.
    Salji, C.
    Swinyard, B. M.
    Ferlet, M.
    van der Wiel, M. H. D.
    Smith, A. J.
    Fulton, T.
    Griffin, M. J.
    Baluteau, J. -P.
    Benielli, D.
    Glenn, J.
    Hopwood, R.
    Imhof, P.
    Lim, T.
    Lu, N.
    Panuzzo, P.
    Pearson, C.
    Sidher, S.
    Valtchanov, I.
    ASTRONOMY & ASTROPHYSICS, 2013, 556
  • [27] Towards a Graphical User Interface for the SPIRE spectrometer pipeline.
    Ordenovic, C.
    Surace, C.
    Baluteau, J. P.
    Benielli, D.
    Davis, P.
    Fulton, T.
    ADVANCED SOFTWARE AND CONTROL FOR ASTRONOMY II, PTS 1 & 2, 2008, 7019
  • [28] A low-background 3He bolometer array test facility and its use in evaluating prototype arrays for FIRST-SPIRE
    Hargrave, PC
    Maffei, B
    Hermoso, R
    Gannaway, G
    Griffin, MJ
    Ade, PAR
    Haynes, CV
    Tucker, CE
    Moseley, SH
    Bock, JJ
    Rodriguez, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2): : 427 - 431
  • [29] The data processing pipeline for the Herschel SPIRE Fourier Transform Spectrometer
    Fulton, T.
    Naylor, D. A.
    Polehampton, E. T.
    Valtchanov, I.
    Hopwood, R.
    Lu, N.
    Baluteau, J. -P.
    Mainetti, G.
    Pearson, C.
    Papageorgiou, A.
    Guest, S.
    Zhang, L.
    Imhof, P.
    Swinyard, B. M.
    Griffin, M. J.
    Lim, T. L.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2016, 458 (02) : 1977 - 1989
  • [30] The Herschel/SPIRE Spectrometer Phase Correction Data Processing Tasks
    Fulton, Trevor
    Naylor, David
    Polehampton, Edward
    Hopwood, Rosalind
    Valtchanov, Ivan
    Lu, Nanyao
    Marchili, Nicola
    Zaretski, Jeremy
    ASTRONOMICAL DATA ANALYSIS SOFTWARE AND SYSTEMS: XXIV, 2015, 495 : 343 - 346