The quality of reporting of diagnostic accuracy studies published in ophthalmic journals

被引:33
|
作者
Siddiqui, MAR
Azuara-Blanco, A
Burr, J
机构
[1] Grampian Univ Hosp NHS Trust, Dept Ophthalmol, Aberdeen, Scotland
[2] Univ Aberdeen, Hlth Serv Res Unit, Aberdeen AB9 1FX, Scotland
关键词
D O I
10.1136/bjo.2004.051862
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards far Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO=5, Archives= 1, BJO=2, IOVS=2, and Ophthalmology= 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n=,4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.
引用
收藏
页码:261 / 265
页数:5
相关论文
共 50 条
  • [21] Adherence to the Standards for Reporting of Diagnostic Accuracy Studies (STARD): a survey of four journals in laboratory medicine
    Zheng, Fei-Fei
    Shen, Wei-Hong
    Gong, Fang
    Hu, Zhi-De
    Lippi, Giuseppe
    Simundic, Ana-Maria
    Bossuyt, Patrick M. M.
    Plebani, Mario
    Zhang, Kaiping
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (11)
  • [22] Quality of Reporting in Randomized Trials Published in High-Quality Surgical Journals
    Sinha, Sidhartha
    Sinha, Shrestha
    Ashby, Elizabeth
    Jayaram, Raja
    Grocott, Michael P. W.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2009, 209 (05) : 565 - 571
  • [23] ADEQUATE REPORTING OF DENTAL DIAGNOSTIC ACCURACY STUDIES IS LACKING: AN ASSESSMENT OF REPORTING IN RELATION TO THE STANDARDS FOR REPORTING OF DIAGNOSTIC ACCURACY STUDIES STATEMENT
    Durkan, Michael
    Chauhan, Ravi
    Pandis, Nicolaos
    Cobourne, Martyn T.
    Seehra, Jadbinder
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2019, 19 (03) : 283 - 294
  • [24] Reporting Bias in Imaging Diagnostic Test Accuracy Studies: Are Studies With Positive Conclusions or Titles Submitted and Published Faster?
    Treanor, Lee M.
    Frank, Robert A.
    Atyani, Almohannad
    Sharifabadi, Anahita Dehmoobad
    Hallgrimson, Zachary
    Fabiano, Nicholas
    Salameh, Jean-Paul
    McGrath, Trevor A.
    Korevaar, Daniel A.
    Bossuyt, Patrick
    McInnes, Matthew D. F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 216 (01) : 225 - 232
  • [25] Reporting quality of randomised controlled trials published in prosthodontic and implantology journals
    Kloukos, D.
    Papageorgiou, S. N.
    Doulis, I.
    Petridis, H.
    Pandis, N.
    JOURNAL OF ORAL REHABILITATION, 2015, 42 (12) : 914 - 925
  • [26] The statistical reporting quality of articles published in 2010 in five dental journals
    Vahanikkila, Hannu
    Tjaderhane, Leo
    Nieminen, Pentti
    ACTA ODONTOLOGICA SCANDINAVICA, 2015, 73 (01) : 76 - 80
  • [27] Quality of Intervention Reporting in Randomized Clinical Trials Published in Urology Journals
    Johnson, Bradley S.
    Fladie, Ian
    Jellison, Sam
    McMurray, Megan
    Narayan, Vikram
    Vassar, Matt
    EUROPEAN UROLOGY, 2020, 77 (03) : 296 - 298
  • [28] Improving the quality of reporting of studies of diagnostic accuracy: Let's STARD now
    Christopher, Mary M.
    VETERINARY CLINICAL PATHOLOGY, 2007, 36 (01) : 6 - 6
  • [29] The quality of reporting of diagnostic accuracy studies in diabetic retinopathy screening: a systematic review
    Zafar, Atif
    Khan, Ghulam Ishaq
    Siddiqui, M. A. Rehman
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 36 (06): : 537 - 542
  • [30] The quality of reporting of diagnostic accuracy studies in glaucoma using scanning laser polarimetry
    Paranjothy, Bhuma
    Shunmugam, Manoharan
    Azuara-Blanco, Augusto
    JOURNAL OF GLAUCOMA, 2007, 16 (08) : 670 - 675