In-stent restenosis associated with stent malapposition: Seven year optical coherence tomography findings

被引:12
|
作者
Santos, Maria C. [1 ]
Lin, Tina [1 ]
Barlis, Peter [1 ]
机构
[1] Univ Melbourne, Northern Hosp, Dept Cardiol, Melbourne, Vic 3076, Australia
关键词
Angiography; Coronary stents; Optical coherence tomography; ELUTING STENT; STRUT COVERAGE; IMPLANTATION; THROMBOSIS;
D O I
10.1016/j.ijcard.2010.02.068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stent thrombosis and in-stent restenosis remain significant issues in post-coronary angioplasty care despite advances in anti-platelet therapy and stent technology. Angiographic predictors of stent failure have been proposed, but its precise mechanism has been difficult to elucidate on conventional coronary angiography and intravascular ultrasound due to the low resolution of either approach. Optical coherence tomography (OCT) as a high-resolution intracoronary imaging modality has enabled more detailed insight into the interaction between implanted stent and underlying endothelium, the evolution of unstable plaque, and the pathogenesis of late lumen loss, affirming its place as an essential tool in the modern-day cardiac catheterisation laboratory. We present a case of in-stent restenosis seven years after bare-metal stent insertion, the mechanism of which was gross stent malapposition as clearly demonstrated on OCT examination. © 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:149 / 151
页数:3
相关论文
共 50 条
  • [41] Qualitative and quantitative neointimal characterization by optical coherence tomography in patients presenting with in-stent restenosis
    Xhepa, E.
    Byrne, R. A.
    Rivero, F.
    Rroku, A.
    Cuesta, J.
    Kufner, S.
    Bastante Valiente, T.
    Cassese, S.
    Garcia-Guimaraes, M.
    Schunkert, H.
    Joner, M.
    Perez-Vizcayno, M. J.
    Gonzalo, N.
    Alfonso, F.
    Kastrati, A.
    EUROPEAN HEART JOURNAL, 2018, 39 : 450 - 450
  • [42] In-stent restenosis characteristics and repeat stenting underexpansion: insights from optical coherence tomography
    Yin, Dong
    Mintz, Gary S.
    Song, Lei
    Chen, Zhaoyang
    Lee, Tetsumin
    Kirtane, Ajay J.
    Parikh, Manish A.
    Moses, Jeffrey W.
    Fall, Khady N.
    Jeremias, Allen
    Ali, Ziad A.
    Shlofmitz, Richard A.
    Maehara, Akiko
    EUROINTERVENTION, 2020, 16 (04) : E335 - U81
  • [43] Comparison of tissue characteristics in patients with in-stent restenosis: tissue analysis by optical coherence tomography
    Fusazaki, T.
    Itoh, T.
    Matsui, H.
    Sugawara, S.
    Ishikawa, Y.
    Komuro, K.
    Nakajima, S.
    Goto, I.
    Nakamura, M.
    EUROPEAN HEART JOURNAL, 2011, 32 : 404 - 404
  • [44] Qualitative and quantitative neointimal characterization by optical coherence tomography in patients presenting with in-stent restenosis
    Erion Xhepa
    Robert A. Byrne
    Fernando Rivero
    Andi Rroku
    Javier Cuesta
    Gjin Ndrepepa
    Sebastian Kufner
    Teresa Bastante Valiente
    Salvatore Cassese
    Marcos Garcia-Guimaraes
    Anna Lena Lahmann
    Himanshu Rai
    Heribert Schunkert
    Michael Joner
    María José Pérez-Vizcayno
    Nieves Gonzalo
    Fernando Alfonso
    Adnan Kastrati
    Clinical Research in Cardiology, 2019, 108 : 1059 - 1068
  • [45] Qualitative and quantitative neointimal characterization by optical coherence tomography in patients presenting with in-stent restenosis
    Xhepa, Erion
    Byrne, Robert A.
    Rivero, Fernando
    Rroku, Andi
    Cuesta, Javier
    Ndrepepa, Gjin
    Kufner, Sebastian
    Bastante Valiente, Teresa
    Cassese, Salvatore
    Garcia-Guimaraes, Marcos
    Lahmann, Anna Lena
    Rai, Himanshu
    Schunkert, Heribert
    Joner, Michael
    Jose Perez-Vizcayno, Maria
    Gonzalo, Nieves
    Alfonso, Fernando
    Kastrati, Adnan
    CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (09) : 1059 - 1068
  • [46] Difference in Optical Coherence Tomography Findings of Very Late In-Stent Restenosis Lesions Between After Bare-Metal Stent and Sirolimus-Eluting Stent Implantation
    Tada, Takeshi
    Kadota, Kazushige
    Habara, Seiji
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    CIRCULATION, 2014, 130
  • [47] Optical Coherence Tomography Findings in Patients Presenting With In-Stent Restenosis: A Prospective Observational Study of Patterns of Neointimal Hyperplasia and Associated Risk Factors
    Chaudhary, Gaurav
    Akhtar, Javed
    Roy, Shubhajeet
    Suresh, Timil
    Tewari, Jay
    Shukla, Ayush
    Chandra, Sharad
    Sharma, Akhil
    Pradhan, Akshyaya
    Bhandari, Monika
    Vishwakarma, Pravesh
    Sethi, Rishi
    Singh, Abhishek
    Dwivedi, Sudhanshu K.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [48] TISSUE CHARACTERISTICS OF IN-STENT TISSUE DETECTED BY OPTICAL COHERENCE TOMOGRAPHY MAY AFFECT RE-RESTENOSIS AFTER CUTTING BALLOON ANGIOPLASTY FOR IN-STENT RESTENOSIS
    Taniike, Masayuki
    Nishino, Masami
    Mori, Naoki
    Lee, Yasuharu
    Yoshimura, Takahiro
    Nakamura, Daisuke
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Morita, Hisaki
    Tanouchi, Jun
    Yamada, Yoshio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1802 - E1802
  • [49] Late acquired stent malapposition detected by optical coherence tomography examination
    Bouki, Konstantina P.
    Chatzopoulos, Dionissios N.
    Katsafados, Mihail G.
    Elaiopoulos, Dimitrios A.
    Psychari, Stavroula N.
    Apostolou, Thomas S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 137 (03) : E77 - E78
  • [50] In Vivo Optical Coherence Tomography of Very Late Drug-Eluting Stent Thrombosis Compared With Late In-Stent Restenosis
    Miyazaki, Shinichiro
    Hiasa, Yoshikazu
    Takahashi, Takefumi
    Yano, Yudai
    Minami, Tomoko
    Murakami, Naotsugu
    Mizobe, Michiko
    Tobetto, Yohei
    Nakagawa, Takafumi
    Chen, Po-Min
    Ogura, Riyo
    Miyajima, Hitoshi
    Yuba, Kenichiro
    Hosokawa, Shinobu
    Kishi, Koichi
    Ohtani, Ryuji
    CIRCULATION JOURNAL, 2012, 76 (02) : 390 - 398