Directed Air Flow to Reduce Airborne Particulate and Bacterial Contamination in the Surgical Field During Total Hip Arthroplasty

被引:29
|
作者
Stocks, Gregory W. [2 ]
O'Connor, Daniel P. [1 ]
Self, Sean D. [3 ]
Marcek, Geoff A. [3 ]
Thompson, Brandon L. [2 ]
机构
[1] Univ Houston, Lab Integrated Physiol, Houston, TX 77204 USA
[2] Fondren Orthoped Grp, Houston, TX USA
[3] Nimbic Syst Inc, Houston, TX USA
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 05期
关键词
infection; intraoperative; operating room; environment; OPERATING-ROOM ENVIRONMENT; JOINT REPLACEMENT OPERATIONS; ORTHOPEDIC IMPLANT-SURGERY; TOTAL KNEE REPLACEMENT; ULTRAVIOLET-RADIATION; SITE INFECTION; ULTRACLEAN AIR; VENTILATION; COUNTS; PREVENTION;
D O I
10.1016/j.arth.2010.07.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study evaluated the use of a system that delivers a small field of local, directed air from a high-efficiency particulate air (HEPA) filter to reduce airborne particulate and airborne bacteria in the surgical field during total hip arthroplasty. Thirty-six patients were randomized into 3 groups: with directed air flow, with the directed air flow system present but turned off, and control. Airborne particulate and bacteria were collected from within 5 cm of the surgical wound. All particulate and bacterial counts at the surgical site were significantly lower in the directed air flow group (P<.001). The directed air flow system was effective in reducing airborne particulate and colony-forming units in the surgical field during total hip arthroplasty.
引用
收藏
页码:771 / 776
页数:6
相关论文
共 50 条
  • [31] CORR InsightsA®: Does Preadmission Cutaneous Chlorhexidine Preparation Reduce Surgical Site Infections After Total Hip Arthroplasty?
    Spires, Steven S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (07) : 1589 - 1591
  • [32] Comment on: Purifying air over the operating field with a new mobile laminar airflow device to reduce the possibility of airborne contamination
    Wroblewski, Keith J.
    Hacopian, Alex
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (04): : 513 - 513
  • [33] Femoral Vein Blood Flow During a Total Hip Arthroplasty Using a Modified Heuter Approach
    Mednick, Rachel E.
    Alvi, Hasham M.
    Morgan, Courtney E.
    Stover, Michael D.
    Manning, David W.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (05): : 786 - 789
  • [34] Ultrasound-assisted surgical retrieval of the lost femoral trial head during total hip arthroplasty
    Kuiran Jiao
    Abistanand Ankam
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2019, 66 : 1520 - 1521
  • [35] Ultrasound-assisted surgical retrieval of the lost femoral trial head during total hip arthroplasty
    Jiao, Kuiran
    Ankam, Abistanand
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2019, 66 (12): : 1520 - 1521
  • [36] Does Surgical Approach During Total Hip Arthroplasty Alter Gait Recovery During the First Year Following Surgery?
    Queen, Robin M.
    Schaeffer, Jordan F.
    Butler, Robert J.
    Berasi, Carl C.
    Kelley, Scott S.
    Attarian, David E.
    Bolognesi, Michael P.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 1639 - 1643
  • [37] AIR-EMBOLISM DURING TOTAL HIP-REPLACEMENT - COMPARISON OF 2 SURGICAL TECHNIQUES
    EVANS, RD
    PALAZZO, MGA
    ACKERS, JWL
    BRITISH JOURNAL OF ANAESTHESIA, 1989, 62 (03) : 243 - 247
  • [38] Intraoperative bacterial contamination in total hip and knee arthroplasty is associated with operative duration and peeling of the iodine-containing drape from skin
    Hanada, Mitsuru
    Hotta, Kensuke
    Furuhashi, Hiroki
    Matsuyama, Yukihiro
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (05): : 917 - 921
  • [39] Intraoperative bacterial contamination in total hip and knee arthroplasty is associated with operative duration and peeling of the iodine-containing drape from skin
    Mitsuru Hanada
    Kensuke Hotta
    Hiroki Furuhashi
    Yukihiro Matsuyama
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 917 - 921
  • [40] Surgical treatment of obturator nerve palsy resulting from extrapelvic extrusion of cement during total hip arthroplasty
    Pecina, M
    Lucijanic, I
    Rosic, D
    JOURNAL OF ARTHROPLASTY, 2001, 16 (04): : 515 - 517