Scale inhibitor and recovery optimization for a brackish water supply: pilot test results and full-scale experiences

被引:1
|
作者
Duranceau, S [1 ]
Lovins, WA [1 ]
Foster, JV [1 ]
Taylor, D [1 ]
Morton, J [1 ]
Morton, C [1 ]
机构
[1] Boyle Engn Corp, Orlando, FL 32801 USA
关键词
dispersant; fouling; nanofiltration; reverse osmosis; scaling; scale inhibitor;
D O I
10.2166/ws.2003.0160
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pilot testing was conducted at a brackish water reverse osmosis water treatment plant to identify operational constraints associated with effective scaling control. The test program involved testing select inhibitors/dispersants, feed water pH, and operating recovery as part of a full-scale retrofit from a hollow fiber to spiral-wound reverse osmosis membrane facility. The test results indicated the facility could be operated at elevated recovery, but was sensitive to conditioning with sulfuric acid. Use of sulfuric acid addition to control calcium carbonate scaling was determined to increase calcium sulfate scaling. Membrane autopsy data confirmed calcium sulfate scaling onto the membrane surface with minimal biological and organic content. It was determined that recovery could be increased from 65 to 75 percent by discontinuing sulfuric acid addition and feeding only scale inhibitor. Scale inhibitors with dispersant properties were recommended for full-scale implementation.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 50 条
  • [31] Full-Scale Field Test of Wake Steering
    Fleming, Paul
    Annoni, Jennifer
    Scholbrock, Andrew
    Quon, Eliot
    Dana, Scott
    Schreck, Scott
    Raach, Steffen
    Haizmann, Florian
    Schlipf, David
    WAKE CONFERENCE 2017, 2017, 854
  • [32] FULL-SCALE TEST OF A COMPOSITE TRUSS.
    Bjorhovde, Reidar
    Structural Engineering Report, 1981, (97):
  • [33] Lessons from a full-scale fire test
    Izzuddin, BA
    Moore, DB
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2002, 152 (04) : 319 - 329
  • [34] UV/chlorine control of drinking water taste and odour at pilot and full-scale
    Wang, Ding
    Bolton, James R.
    Andrews, Susan A.
    Hofmann, Ron
    CHEMOSPHERE, 2015, 136 : 239 - 244
  • [35] Full-scale cold bending demonstration test
    Gergess, Antoine N.
    Sen, Rajan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (10) : 1295 - 1304
  • [36] PROPOSAL OF A FLOOD TEST SYSTEM FOR FULL-SCALE HOUSES USING A LARGE-SCALE WATER TANK
    Waki H.
    Takahashi T.
    Oyokawa T.
    Shinagawa K.
    Hirano S.
    Fukuwa N.
    AIJ Journal of Technology and Design, 2022, 28 (68) : 221 - 226
  • [37] Full-scale experiences with anaerobic treatment of industrial wastewater
    Frankin, RJ
    WATER SCIENCE AND TECHNOLOGY, 2001, 44 (08) : 1 - 6
  • [38] CONVENTIONAL RETAINING WALLS - PILOT AND FULL-SCALE STUDIES
    SYMONS, IF
    MURRAY, RT
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 1-DESIGN AND CONSTRUCTION, 1988, 84 : 519 - 538
  • [39] EGYPT MOVES FROM PILOT TO FULL-SCALE COMPOSTING
    HUGHES, EG
    BIOCYCLE, 1987, 28 (06) : 26 - 27
  • [40] PILOT FULL-SCALE PLANT FOR CONTINUOUS METHYLURACIL MANUFACTURE
    POPOV, VV
    LOPATIN, EB
    VITVITSKAYA, AS
    BALABANOVICH, GN
    FRIDMAN, IA
    MAKAROV, YN
    YEVSTIGNEYEVA, NB
    KHIMIKO-FARMATSEVTICHESKII ZHURNAL, 1989, 23 (10): : 1263 - 1266