Scale inhibitor and recovery optimization for a brackish water supply: pilot test results and full-scale experiences

被引:1
|
作者
Duranceau, S [1 ]
Lovins, WA [1 ]
Foster, JV [1 ]
Taylor, D [1 ]
Morton, J [1 ]
Morton, C [1 ]
机构
[1] Boyle Engn Corp, Orlando, FL 32801 USA
关键词
dispersant; fouling; nanofiltration; reverse osmosis; scaling; scale inhibitor;
D O I
10.2166/ws.2003.0160
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pilot testing was conducted at a brackish water reverse osmosis water treatment plant to identify operational constraints associated with effective scaling control. The test program involved testing select inhibitors/dispersants, feed water pH, and operating recovery as part of a full-scale retrofit from a hollow fiber to spiral-wound reverse osmosis membrane facility. The test results indicated the facility could be operated at elevated recovery, but was sensitive to conditioning with sulfuric acid. Use of sulfuric acid addition to control calcium carbonate scaling was determined to increase calcium sulfate scaling. Membrane autopsy data confirmed calcium sulfate scaling onto the membrane surface with minimal biological and organic content. It was determined that recovery could be increased from 65 to 75 percent by discontinuing sulfuric acid addition and feeding only scale inhibitor. Scale inhibitors with dispersant properties were recommended for full-scale implementation.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 50 条
  • [1] OZONATION OF COLORED GROUNDWATER PILOT-SCALE AND FULL-SCALE EXPERIENCES
    TAN, L
    AMY, G
    RIGBY, M
    RENNA, J
    KEMP, K
    OZONE-SCIENCE & ENGINEERING, 1991, 13 (01) : 109 - 125
  • [2] Operating experiences with full-scale and pilot-scale membrane bioreactors (MBRs)
    Gomez, Marcel
    Dvorak, Lukas
    Ruzickova, Iveta
    CURRENT OPINION IN BIOTECHNOLOGY, 2011, 22 : S78 - S79
  • [3] Full-scale test of buried water supply pipeline network with explosion simulation earthquake
    Wang, Chuang
    Liu, Wei
    Li, Jie
    Tongji Daxue Xuebao/Journal of Tongji University, 2015, 43 (10): : 1487 - 1496
  • [4] Shaking Table Test of Water Supply Pipes Installed in a Full-Scale Masonry Structure
    Houli Wu
    Endong Guo
    Dezhang Sun
    Chenxi Mao
    Haoyu Zhang
    Zhibin Liu
    KSCE Journal of Civil Engineering, 2022, 26 : 824 - 836
  • [5] Shaking Table Test of Water Supply Pipes Installed in a Full-Scale Masonry Structure
    Wu, Houli
    Guo, Endong
    Sun, Dezhang
    Mao, Chenxi
    Zhang, Haoyu
    Liu, Zhibin
    KSCE JOURNAL OF CIVIL ENGINEERING, 2022, 26 (02) : 824 - 836
  • [6] Comparison of ultraviolet pilot trial results with full-scale operation
    Hartz, K
    Griffith, J
    WATER-ENGINEERING & MANAGEMENT, 2001, 148 (01): : 37 - 40
  • [7] Full-scale and pilot-scale soil washing
    Mann, MJ
    JOURNAL OF HAZARDOUS MATERIALS, 1999, 66 (1-2) : 119 - 136
  • [8] Full-scale and pilot-scale soil washing
    14497 North Dale Mabry Highway, Tampa, FL 33618, United States
    J. Hazard. Mater., 1-2 (119-136):
  • [9] PILOT AND FULL-SCALE TREATMENT EXPERIENCES ON PAPER-MILL EFFLUENTS
    OZTURK, I
    EROGLU, V
    TOROZ, I
    WATER SCIENCE AND TECHNOLOGY, 1990, 22 (09) : 255 - 263
  • [10] FULL-SCALE PRESSURIZED WATER-REACTOR SAFETY VALVE TEST-RESULTS
    AUBLE, TE