Gas filled prototype of a CdZnTe pixel detector

被引:0
|
作者
Ramsey, B
Sharma, D
Sipila, H
Gostilo, V
Loupilov, A
机构
[1] Baltic Sci Instrument, LV-1005 Riga, Latvia
[2] Metorex Int Oy, FIN-02631 Espoo, Finland
[3] George C Marshall Space Flight Ctr, Dept Space Sci, Huntsville, AL 35812 USA
关键词
Cdznte; pixel; imaging detectors;
D O I
10.1016/S0969-806X(01)00365-6
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
CdZnTe pixel structures are currently the most promising detectors for the focal planes of hard X-ray telescopes, for astronomical observation in the range 5-100keV. In Sharma et al. (Proc. SPIE 3765 (1999) 822) and Ramsey et al. (Nucl. Instrum. Methods A 458 (2001) 55) we presented preliminary results on the development of prototype 4 x 4 CdZnTe imaging detectors operated under vacuum. These pixel detectors were installed inside vacuum chambers on three-stage Peltier coolers providing detector temperatures down to -40 degreesC. A miniature sputter ion pump inside each chamber maintained the necessary vacuum of 10(-5)Torr. At a temperature of -20 degreesC we achieved an FWHM energy resolution of between 2% and 3% at 60 keV and approximate to 15% at 5.9 keV; however, the dependency on temperature was weak and at +20 degreesC the respective resolutions were 3% and 20%. As the detectors could be operated at room temperature without loss of their good characteristics it was possible to exclude the sputter ion pump and fill the chamber with dry nitrogen instead. We have tested a nitrogen-filled CdZnTe (5 x 5 x 1 mm(3)) prototype having 0.65 x 0.65 mm(2) readout pads on a 0.75 mm. pitch. The interpixel resistance at an applied voltage of 10 V was higher than 50 G Omega and the pixel leakage currents at room temperature with a bias of 200 V between each pad and the common electrode did not exceed 0.8 nA. The pixel detector inside the microassembly, which also contained the input stages of the preamplifiers, was installed on a Peltier cooler to maintain the detector temperature at +20 degreesC. To define real leakage currents of the pixels in their switched-on state we have checked the voltage on the preamplifiers feedback resistors. The resulting currents were 10-50 pA at a detector bias of 500 V. Under test, the typical energy resolution per pixel at +20 degreesC was approximate to3% at energy 59.6 keV and approximate to 20% at energy 5.9 keV, which are similar to the values obtained in the vacuum prototype at room temperature (Nucl. Instrum. Methods A 458 (2001) 55). Using the three stage Peltier cooler it is possible to cool the pixel detector in the nitrogen atmosphere to 0 degreesC which would slightly improve these spectrometrical characteristics. Thus the conclusion here is that the use of a nitrogen environment instead of a vacuum one did not cause any deterioration of the characteristics of the CdZnTe imaging detector. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:663 / 664
页数:2
相关论文
共 50 条
  • [21] A new design for the Gas Pixel Detector
    Muleri, Fabio
    Bellazzini, Ronaldo
    Brez, Alessandro
    Costa, Enrico
    Fabiani, Sergio
    Minuti, Massimo
    Pinchera, Michele
    Rubini, Alda
    Soffitta, Paolo
    Spandre, Gloria
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [22] Use of CdZnTe pixel arrays with multiplexer readout to map detector crystal properties
    Barber, HB
    Dereniak, E
    Eskin, JD
    Hilton, NR
    Marks, DG
    Matherson, KJ
    Woolfenden, JM
    Young, ET
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 286 - 290
  • [23] Silicon-Gas Pixel Detector
    Bashindzhagyan, G.
    Korotkova, N.
    Romaniouk, A.
    Sinev, N.
    Tikhomirov, V.
    INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS, 2017, 798
  • [24] Characterization of a CMOS Pixel Sensor prototype for the CEPC vertex detector
    Wang, Wei
    Wu, Tianya
    Liang, Zhijun
    Zhang, Ying
    Wei, Wei
    Li, Xiaoting
    Casanova, Raimon
    Wei, Xiaomin
    Zhang, Liang
    Dong, Jianing
    Lu, Weiguo
    Zheng, Ran
    Li, Mengzhao
    Yang, Xuan
    Fan, Yunyun
    Grinstein, Sebastian
    Costa, Joao Guimaraes da
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1056
  • [25] First results from the ALICE silicon pixel detector prototype
    Riedler, P
    Anelli, G
    Antinori, F
    Burns, M
    Banicz, K
    Caliandro, R
    Campbell, M
    Caselle, M
    Chochula, P
    Dinapoli, R
    Easo, S
    Elia, D
    Formenti, F
    Girone, M
    Gys, T
    van Hunen, JJ
    Jusko, A
    Kluge, A
    Krivda, M
    Lenti, V
    Luptak, M
    Manzari, V
    Meddi, F
    Morel, M
    Riggi, F
    Snoeys, W
    Stefanini, G
    Wyllie, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (01): : 111 - 118
  • [26] Radiation tolerance of prototype BTeV pixel detector readout chips
    Chiodini, G
    Appel, JA
    Cardoso, G
    Christian, DC
    Coluccia, MR
    Hall, B
    Hoff, J
    Kwan, SW
    Mekkaoui, A
    Yarema, R
    Zimmerman, S
    Uplegger, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (06) : 2895 - 2901
  • [27] A Monolithic Active Pixel Sensor prototype for the CEPC vertex detector
    Yang, Ping
    Ren, Weiping
    Sun, Xiangming
    Huang, Guangming
    Xiao, Le
    Gao, Chaosong
    Huang, Xing
    Zhou, Wei
    Li, Yashu
    Liu, Jianchao
    You, Bihui
    Zhang, Li
    Liu, Jun
    Zhang, Ying
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 : 82 - 86
  • [28] Performance of a prototype CdZnTe detector module for hard X-ray astrophysics
    Slavis, KR
    Dowkontt, P
    Duttweiler, F
    Epstein, JW
    Hink, PL
    Huszar, GL
    Kalemci, E
    Leblanc, PC
    Matteson, JL
    Pelling, MR
    Rothschild, RE
    Stephan, E
    Tümer, T
    Visser, G
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 249 - 256
  • [29] Test results of a CdZnTe pixel detector read out by RENA-2 IC
    Tümer, TO
    Cajipe, VB
    Clajus, M
    Duttweiler, F
    Hayakawa, S
    Matteson, JL
    Shirley, A
    Yossifor, O
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4369 - 4372
  • [30] First test results from a high resolution CdZnTe pixel detector with VLSI readout
    Cook, WR
    Boggs, SE
    Bolotnikov, AE
    Burnham, JA
    Harrison, FA
    Kecman, B
    Matthews, B
    Schindler, SM
    Fitzsimmons, MJ
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS, 1999, 3769 : 92 - 96