High-resolution CdTe detector and applications to imaging devices

被引:90
|
作者
Takahashi, T [1 ]
Watanabe, S
Kouda, M
Sato, G
Okada, Y
Kubo, S
Kuroda, Y
Onishi, M
Ohno, R
机构
[1] Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2298510, Japan
[2] Univ Tokyo, Dept Phys, Bunkyo Ku, Tokyo 1130033, Japan
[3] Clear Pulse Co Ltd, Chuo Ku, Ohta, Tokyo 1430024, Japan
[4] Mitsubishi Heavy Ind Co Ltd, Nagoya Guidance & Prop Syst Works, Aichi 4858561, Japan
[5] Daiichi Syst Engn Co Ltd, Aichi 4858561, Japan
[6] ACRORAD, Okinawa 9042234, Japan
关键词
CdTe; CdZnTe; pixel detector;
D O I
10.1109/23.940067
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using a high quality Cadmium Telluride (CdTe) wafer, we formed a Schottky junction and operated the detector as a diode (CdTe diode). The low leakage current of the CdTe diode allows us to apply a much higher bias voltage than was possible with the previous CdTe detectors. For a relatively thin detector of similar to 0.5 mm thick, the high bias voltage results in a high electric field in the device. Both the improved charge collection efficiency and the low-leakage current lead to an energy resolution of 1.1 keV FWHM at 60 keV for a 2 x 2 mm(2) device and 2 keV for a 10 x 10 mm(2) device at 5 degreesC without any charge-loss correction electronics. For astrophysical applications, we have developed an initial prototype CdTe pixel detector based on the CdTe diode. The detector has 400 pixels with a pixel size of 625 x 625 mum(2). Each pixel is gold-stud bonded to a fanout board and routed to a front end ASIC to measure pulse height information for each gamma -ray photon.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 50 条
  • [41] High-Resolution Numerical Study of Conductance and Noise Imaging of Mesoscopic Devices
    M. Macucci
    P. Marconcini
    Journal of Computational Electronics, 2004, 3 : 429 - 433
  • [42] A HIGH-RESOLUTION BETA- DETECTOR
    CHARON, Y
    CUZON, JC
    TRICOIRE, H
    VALENTIN, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 748 - 753
  • [43] A miniaturized detector for high-resolution SEMPA
    R. Frömter
    H.P. Oepen
    J. Kirschner
    Applied Physics A, 2003, 76 : 869 - 871
  • [44] Large area gamma-ray imaging detector based on high resolution CdTe diode
    Mitani, T
    Nakamura, H
    Uno, S
    Takahashi, T
    Nakazawa, K
    Watanabe, S
    Tajima, H
    Nomachi, M
    Fukazawa, Y
    Kubo, S
    Kuroda, Y
    Onishi, M
    Ohno, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 274 - 277
  • [45] High-Resolution Numerical Study of Conductance and Noise Imaging of Mesoscopic Devices
    Macucci, M.
    Marconcini, P.
    JOURNAL OF COMPUTATIONAL ELECTRONICS, 2004, 3 (3-4) : 429 - 433
  • [46] Efficient atmospheric simulation for high-resolution radar imaging applications
    Cheong, B.L. (boonleng@doppler.unl.edu), 1600, American Meteorological Society (21):
  • [47] A miniaturized detector for high-resolution SEMPA
    Frömter, R
    Oepen, HP
    Kirschner, J
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2003, 76 (06): : 869 - 871
  • [48] Applications of high-resolution in vivo imaging for small animal research
    Theodoropoulos, Catherine
    TRANSGENIC RESEARCH, 2006, 15 (06) : 789 - 789
  • [49] High resolution X-ray imaging detector based on polycrystalline CdTe thick films
    Sorgenfrei, R.
    Zwerger, A.
    Disch, C.
    Fiederle, M.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3716 - 3718
  • [50] Clinical applications of high-resolution ocular magnetic resonance imaging
    Tanitame, Keizo
    Sone, Takashi
    Kiuchi, Yoshiaki
    Awai, Kazuo
    JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (09) : 695 - 705