T2-prepared balanced steady-state free precession (bSSFP) for quantifying whole-blood oxygen saturation at 1.5T

被引:11
|
作者
Rodriguez-Soto, Ana E. [1 ]
Abdulmalik, Osheiza [2 ]
Langham, Michael C. [1 ]
Schwartz, Nadav [3 ]
Lee, Hyunyeol [1 ]
Wehrli, Felix W. [1 ]
机构
[1] Univ Penn, Dept Radiol, Lab Struct Physiol & Funct Imaging, Philadelphia, PA 19104 USA
[2] Childrens Hosp Philadelphia, Div Hematol, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Obstet & Gynecol, Perelman Sch Med, Maternal & Child Hlth Res Program, Philadelphia, PA 19104 USA
关键词
T-2-based oximetry; whole blood; oxygen saturation; CEREBRAL METABOLIC-RATE; MAGNETIC-RESONANCE; MRI QUANTIFICATION; T-2; BRAIN; RELAXATION; VALIDATION; SUSCEPTIBILITY; CONSUMPTION; CONTRAST;
D O I
10.1002/mrm.26835
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo establish a calibration equation to convert human blood T-2 to the full range of oxygen saturation levels (HbO(2)) and physiologic hematocrit (Hct) values using a T-2-prepared balanced steady-state free precession sequence (T-2-SSFP) at 1.5T. MethodsBlood drawn from 10 healthy donors (29.13.9 years old) was prepared into samples of varying HbO(2) and Hct (n=79), and imaged using T-2-SSFP sequence at 37 degrees C and interrefocusing interval (180)=12 ms. The relationship between blood T-2, HbO(2), and Hct was established based on the model R2=R2,plasma+Hct(R2,RBC-R2,plasma)+k<bold>Hct</bold>(1-Hct)<bold></bold>(1-HbO2)2. Measured R-2 and HbO(2) levels were fit by the model yielding values of R2,plasma, R2,RBC, and k. T-2-SSFP and the established calibration equation were applied to extract HbO(2) at the superior sagittal sinus (SSS) in vivo and were compared with susceptometry-based oximetry. ResultsConstants derived from the fit were: k=74.2 [s(-1)], R2,plasma =1.5 [s(-1)], R2,RBC =11.6 [s(-1)], the R-2 of the fit was 0.95. Average HbO(2) at the SSS in seven healthy volunteers was 65%+/- 7% and 66%+/- 7% via T-2- and susceptometry-based oximetry, respectively. Bland-Altman analysis indicated agreement between the two oximetric methods with no significant bias. ConclusionThe calibration constants presented here should ensure improved accuracy for whole-blood oximetry based on T-2-SSFP at 1.5T. Magn Reson Med 79:1893-1900, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:1893 / 1900
页数:8
相关论文
共 50 条
  • [21] Optimization of the Balanced Steady State Free Precession (bSSFP) Pulse Sequence for Magnetic Resonance Imaging of the Mouse Prostate at 3T
    Mallett, Christiane L.
    Foster, Paula J.
    PLOS ONE, 2011, 6 (04):
  • [22] Rapid 3D in vivo 1H human lung respiratory imaging at 1.5T using ultra-fast balanced steady-state free precession
    Pusterla, Orso
    Bauman, Grzegorz
    Wielpuetz, Mark O.
    Nyilas, Sylvia
    Latzin, Philipp
    Heussel, Claus P.
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 1059 - 1069
  • [23] Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 T - Comparison with steady-state free precession technique at 1.5 T
    Liu, Xin
    Bi, Xiaoming
    Huang, Jie
    Jerecic, Renate
    Carr, James
    Li, Debiao
    INVESTIGATIVE RADIOLOGY, 2008, 43 (09) : 663 - 668
  • [24] 130 Contrast-enhanced whole-heart coronary MR angiography at 3.0 T: comparison to steady-state free precession technique at 1.5 T
    Xin Liu
    Xiaoming Bi
    Nondas Leloudas
    Renate Jerecic
    James Carr
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [25] A NEW METHOD OF MEASURING T2 USING STEADY-STATE FREE PRECESSION
    MATSUI, S
    KURODA, M
    KOHNO, H
    JOURNAL OF MAGNETIC RESONANCE, 1985, 62 (01) : 12 - 18
  • [26] Optimization of steady-state free precession MRI for lung ventilation imaging with 19F C3F8 at 1.5T and 3T
    Maunder, Adam
    Rao, Madhwesha
    Robb, Fraser
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1130 - 1142
  • [27] Revisiting the Potential of Alternating Repetition Time Balanced Steady-State Free Precession Imaging of the Abdomen at 3 T
    Gurney-Champion, Oliver J.
    Nederveen, Aart J.
    Klaassen, Remy
    Engelbrecht, Marc R.
    Bel, Arjan
    van Laarhoven, Hanneke W. M.
    Stoker, Jaap
    Goncalves, Sonia I.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 560 - 568
  • [28] Brain oxygen saturation assessment in neonates using T2-prepared blood imaging of oxygen saturation and near-infrared spectroscopy
    Alderliesten, Thomas
    De Vis, Jill B.
    Lemmers, Petra M. A.
    Hendrikse, Jeroen
    Groenendaal, Floris
    van Bel, Frank
    Benders, Manon J. N. L.
    Petersen, Esben T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (03): : 902 - 913
  • [29] Phase imaging with multiple phase-cycled balanced steady-state free precession at 9.4T
    Kim, Jae-Woong
    Kim, Seong-Gi
    Park, Sung-Hong
    NMR IN BIOMEDICINE, 2017, 30 (06)
  • [30] Measurement of T1ρ dispersion with compressed sensing and magnetization prepared radial balanced steady-state free precession in spontaneous human osteoarthritis
    Pala, S.
    Paajanen, A.
    Ristaniemi, A.
    Nippolainen, E.
    Afara, I. O.
    Nykanen, O.
    Nissi, M. J.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (05) : 2127 - 2139