Long-term Stability of LED Filament Standard Lamps for total luminous flux

被引:0
|
作者
Yan, Jinyun [1 ]
Liu, Hui [1 ]
Zhao, Weiqiang [1 ]
Su, Ying [1 ]
机构
[1] Natl Inst Metrol, 18 Bei San Huan Dong Lu, Beijing 100029, Peoples R China
来源
OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VIII | 2021年 / 11899卷
关键词
LED filament lamp; photometric standard; long-term stability; luminous flux;
D O I
10.1117/12.2602256
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
NIM has developed LED filament standard lamps for total luminous flux with excellent long-term stability, uniform distribution of luminous intensity, and the E27 Edison screw base which is compatible with present incandescent standard lamps. The standard lamp consists of six high-power LED filaments which are sealed in a G150 glass bulb and filled with He gas. All the 12 lamps were aged for 500 hours before the 315 days' long-term stability test. 9 lamps are lighted for 1 hour every day. One lamp is continuously operated for about 6000 hours, and 2 lamps are well stored on a shelf. The results show that the long-term stabilities of the 3 cases are better than 0.07%. This LED filament lamp could be promising as a transfer standard of total luminous flux.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] LONG-TERM STABILITY
    GOLDEMBERG, RL
    DRUG & COSMETIC INDUSTRY, 1988, 143 (05): : 26 - 26
  • [42] Long-term drift of the coronal source magnetic flux and the total solar irradiance
    Lockwood, M
    Stamper, R
    GEOPHYSICAL RESEARCH LETTERS, 1999, 26 (16) : 2461 - 2464
  • [43] Long-term performance of screwbase compact fluorescent lamps
    O'Rourke, C
    Figueiro, MG
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 2001, 30 (02): : 30 - +
  • [44] TOTAL LUMINOUS FLUX AND CHROMACITY MEASUREMENT FOR LED LUMINAIRES USING ABSOLUTE INTERATING SPHERE METHOD
    Pan, J.
    Qian, F.
    Min, F.
    Li, Y.
    27TH SESSION OF THE CIE, VOL. 1, PTS 1 AND 2, 2011, : 478 - 481
  • [45] LONG-TERM PRESERVATION OF ACTIVE LUMINOUS BACTERIA BY LYOPHILIZATION
    JANDA, I
    OPEKAROVA, M
    JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1989, 3 (01): : 27 - 29
  • [46] Long-term Stability of Total RNA in RNAstable® as Evaluated by Expression Microarray
    Stevenson, Holly S.
    Wang, Yonghong
    Muller, Rolf
    Edelman, Daniel C.
    BIOPRESERVATION AND BIOBANKING, 2015, 13 (02) : 114 - 122
  • [47] A Survey on Long-Term Stability of Stock Standard Solutions in Pesticide Residue Analysis
    Stefanelli, Patrizia
    Barbini, Danilo Attard
    Amendola, Graziella
    Generali, Tiziana
    Girolimetti, Silvana
    Pelosi, Patrizia
    Santilio, Angela
    FOOD ANALYTICAL METHODS, 2015, 8 (05) : 1164 - 1172
  • [48] EVALUATION OF THE UNCERTAINTY OF LONG-TERM STABILITY ON JAPANESE CERTIFIED REFERENCE STANDARD FOR ENZYMES
    Ueda, S.
    Hosogaya, S.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S812 - S812
  • [49] Long-term physico-chemical stability of standard parenteral nutritions for neonates
    Bouchoud, Lucie
    Sadeghipour, Farshid
    Klingmueller, Martin
    Fonzo-Christe, Caroline
    Bonnabry, Pascal
    CLINICAL NUTRITION, 2010, 29 (06) : 808 - 812
  • [50] A Survey on Long-Term Stability of Stock Standard Solutions in Pesticide Residue Analysis
    Patrizia Stefanelli
    Danilo Attard Barbini
    Graziella Amendola
    Tiziana Generali
    Silvana Girolimetti
    Patrizia Pelosi
    Angela Santilio
    Food Analytical Methods, 2015, 8 : 1164 - 1172