Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry

被引:27
|
作者
Robinson, Andrew P. [1 ]
Tipping, Jill [2 ]
Cullen, David M. [1 ]
Hamilton, David [2 ]
Brown, Richard [1 ]
Flynn, Alex [1 ]
Oldfield, Christopher [1 ]
Page, Emma [1 ,2 ]
Price, Emlyn [1 ]
Smith, Andrew [1 ]
Snee, Richard [1 ]
机构
[1] Univ Manchester, Schuster Lab, Sch Phys & Astron, Manchester M13 9PL, Lancs, England
[2] Christie NHS Fdn Trust, CMPE, Wilmslow Rd, Manchester M20 4BX, Lancs, England
来源
EJNMMI PHYSICS | 2016年 / 3卷 / 01期
基金
英国科学技术设施理事会;
关键词
Activity quantification; SPECT; Molecular radiotherapy; 3D printing; Absorbed dose; ABSORBED FRACTIONS; ELECTRONS; ACCURACY; SPHERES;
D O I
10.1186/s40658-016-0148-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Patient-specific absorbed dose calculations for molecular radiotherapy require accurate activity quantification. This is commonly derived from Single-Photon Emission Computed Tomography (SPECT) imaging using a calibration factor relating detected counts to known activity in a phantom insert. Methods: A series of phantom inserts, based on the mathematical models underlying many clinical dosimetry calculations, have been produced using 3D printing techniques. SPECT/CT data for the phantom inserts has been used to calculate new organ-specific calibration factors for Tc-99m and Lu-177. The measured calibration factors are compared to predicted values from calculations using a Gaussian kernel. Results: Measured SPECT calibration factors for 3D printed organs display a clear dependence on organ shape for Tc-99m and Lu-177. The observed variation in calibration factor is reproduced using Gaussian kernel-based calculation over two orders of magnitude change in insert volume for Tc-99m and Lu-177. These new organ-specific calibration factors show a 24, 11 and 8 % reduction in absorbed dose for the liver, spleen and kidneys, respectively. Conclusions: Non-spherical calibration factors from 3D printed phantom inserts can significantly improve the accuracy of whole organ activity quantification for molecular radiotherapy, providing a crucial step towards individualised activity quantification and patient-specific dosimetry. 3D printed inserts are found to provide a cost effective and efficient way for clinical centres to access more realistic phantom data.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [21] Use of patient specific 3D printed neurovascular phantoms to simulate mechanical thrombectomy
    Sommer, Kelsey N.
    Bhurwani, Mohammad Mahdi Shiraz
    Tutino, Vincent
    Siddiqui, Adnan
    Davies, Jason
    Snyder, Kenneth
    Levy, Elad
    Mokin, Maxim
    Ionita, Ciprian N.
    3D PRINTING IN MEDICINE, 2021, 7 (01)
  • [22] Anthropomorphic 3D Printed Prostate Simulator Applied to Dosimetry with Fricke Gel in Radiotherapy
    Cruz, Gisela Benacon
    de Andrade, Marcelino Monteiro
    Oliveira e Silva, Luis Felipe
    Faria, Sylvia de Sousa
    Leite, Edmario Brandao
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL. 2, 2019, 70 (02): : 745 - 752
  • [23] A Practical Workflow to Calculate 3D BED Composite Plan Using Organ-Specific Radiobiological Parameters
    Quashie, E.
    Tai, A.
    Prior, P. W., Jr.
    Awan, M. J.
    Schultz, C. J.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E242 - E242
  • [24] A review of 3D printed patient specific immobilisation devices in radiotherapy
    Asfia, Amirhossein
    Novak, James, I
    Mohammed, Mazher Iqbal
    Rolfe, Bernard
    Kron, Tomas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 13 : 30 - 35
  • [25] Camera-based radiotherapy dosimetry using dual-material 3D printed scintillator arrays
    Lynch, Nicholas
    Robar, James L.
    Monajemi, Thalat
    MEDICAL PHYSICS, 2023, 50 (03) : 1824 - 1842
  • [26] 3D Printed Calibration Micro-phantoms for Validation of Super-Resolution Ultrasound Imaging
    Ommen, Martin Lind
    Schou, Mikkel
    Beers, Christopher
    Jensen, Jorgen Arendt
    Larsen, Niels Bent
    Thomsen, Erik Vilain
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1212 - 1215
  • [27] 3D printed calibration micro-phantoms for super-resolution ultrasound imaging validation
    Ommen, Martin Lind
    Schou, Mikkel
    Beers, Christopher
    Jensen, Jorgen Arendt
    Larsen, Niels Bent
    Thomsen, Erik Vilain
    ULTRASONICS, 2021, 114
  • [28] Radiation dosimetry for thyroid cancer patients and validation using 3D printing phantoms
    El-Din M.M.E.
    Massoud E.
    El-Agamawi A.Y.
    Kany A.M.
    El-Din M.R.E.
    1600, Inderscience Publishers (14): : 339 - 351
  • [29] Fiducial detection and registration for 3D IMRT QA with organ-specific dose information
    Wang, Yi-Fang
    Dona, Olga
    Xu, Yuanguang
    Adamovics, John
    Wuu, Cheng-Shie
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (05): : 24 - 35
  • [30] In vitro 3D modeling of host organ-specific whole tumor responses to radiation
    Volgin, A.
    LeRoux, L.
    Maxwell, D.
    Schellingerhou, D.
    Thitai-Kumar, A.
    He, Y.
    Gelovani, J.
    Schwartz, D. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S682 - S683