brachytherapy;
iodine-125;
prostate;
radiation dosimetry;
Monte Carlo;
D O I:
10.1118/1.1601914
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
The SeedLink(TM) brachytherapy system is comprised from an assembly of I-Plant(TM) 3500 interstitial brachytherapy seeds and bioresorbable spacers joined together by a 6-mm-long titanium sleeve centered over each seed. This device is designed to maintain specified spacing between seeds during treatment thereby decreasing implant preparation time and reducing radionuclide migration within the prostate and periprostatic region. Reliable clinical treatment and planning applications necessitate accurate dosimetric data for source evaluation, therefore the authors report the results of a Monte Carlo study designed to calculate the AAPM Task Group Report No. 43 dosimetric parameters for the SeedLink brachytherapy source and compare these values against previously published Monte Carlo study results of the I-Plant 3500 brachytherapy seed. For this investigation, a total of 1 X 10(9) source photon histories were processed for each set of in-water and in-air calculations using the MCNP4C2 Monte Carlo radiation transport code (RSICC). Statistically, the radial dose function, g(r), and the dose-rate constant, Lambda, were identical to the values calculated previously for the Model 3500 with the dose-rate constant evaluated to be Lambda=1.000+/-0.026 cGyh(-1) U-1. The titanium sleeve used in SeedLink to bind together Model 3500 seeds and spacers resulted in slightly greater dosimetric anisotropy as exhibited in the anisotropy function, F(r, theta), the anisotropy factor, phi(an) (r), and the anisotropy constant, (φ) over bar (an), which was calculated to be (φ) over bar (an)=0.91+/-0.01, or roughly 2% lower than the value calculated previously for the Model 3500. These results indicate that the radiological characteristics of the SeedLink dosimetry system are comparable to those obtained for previously characterized single seeds such as the Implant Sciences Model 3500 I-Plant seed. (C) 2003 American Association of Physicists in Medicine.
机构:
Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, IranUniv Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Joya, Musa
Nedaie, Hassan Ali
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, IranUniv Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Nedaie, Hassan Ali
Geraily, Ghazale
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, IranUniv Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Geraily, Ghazale
Rezaei, Hadi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Dept Nucl Med, Tehran, IranUniv Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Rezaei, Hadi
Bromand, Awaz
论文数: 0引用数: 0
h-index: 0
机构:
Shahid Beheshti Univ Med Sci, Sch Med, Dept Biomed Engn & Med Phys, Tehran, IranUniv Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Bromand, Awaz
Ghorbani, Mahdi
论文数: 0引用数: 0
h-index: 0
机构:
Kabul Univ Med Sci, Dept Radiol, Kabul, AfghanistanUniv Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Ghorbani, Mahdi
Sheikhzadeh, Peyman
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
Ghor Inst Higher Educ, Dept Phys, Ghor, AfghanistanUniv Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Tehran, Iran
机构:
Tufts Univ, Sch Med, New England Med Ctr 246, Dept Radiat Oncol, Boston, MA 02111 USATufts Univ, Sch Med, New England Med Ctr 246, Dept Radiat Oncol, Boston, MA 02111 USA