Monte Carlo calculated TG-43 dosimetry parameters for the SeedLink™ 125iodine brachytherapy system

被引:2
|
作者
Medich, DC
Munro, JJ
机构
[1] Univ Massachusetts, Radiat Lab, Lowell, MA 01854 USA
[2] Implant Sci Corp, Wakefield, MA 01880 USA
关键词
brachytherapy; iodine-125; prostate; radiation dosimetry; Monte Carlo;
D O I
10.1118/1.1601914
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The SeedLink(TM) brachytherapy system is comprised from an assembly of I-Plant(TM) 3500 interstitial brachytherapy seeds and bioresorbable spacers joined together by a 6-mm-long titanium sleeve centered over each seed. This device is designed to maintain specified spacing between seeds during treatment thereby decreasing implant preparation time and reducing radionuclide migration within the prostate and periprostatic region. Reliable clinical treatment and planning applications necessitate accurate dosimetric data for source evaluation, therefore the authors report the results of a Monte Carlo study designed to calculate the AAPM Task Group Report No. 43 dosimetric parameters for the SeedLink brachytherapy source and compare these values against previously published Monte Carlo study results of the I-Plant 3500 brachytherapy seed. For this investigation, a total of 1 X 10(9) source photon histories were processed for each set of in-water and in-air calculations using the MCNP4C2 Monte Carlo radiation transport code (RSICC). Statistically, the radial dose function, g(r), and the dose-rate constant, Lambda, were identical to the values calculated previously for the Model 3500 with the dose-rate constant evaluated to be Lambda=1.000+/-0.026 cGyh(-1) U-1. The titanium sleeve used in SeedLink to bind together Model 3500 seeds and spacers resulted in slightly greater dosimetric anisotropy as exhibited in the anisotropy function, F(r, theta), the anisotropy factor, phi(an) (r), and the anisotropy constant, (φ) over bar (an), which was calculated to be (φ) over bar (an)=0.91+/-0.01, or roughly 2% lower than the value calculated previously for the Model 3500. These results indicate that the radiological characteristics of the SeedLink dosimetry system are comparable to those obtained for previously characterized single seeds such as the Implant Sciences Model 3500 I-Plant seed. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2503 / 2508
页数:6
相关论文
共 50 条
  • [21] Monte Carlo Determination of Dosimetric Parameters of a New 125I Brachytherapy Source According to AAPM TG-43 (U1) Protocol
    Baghani, Hamid Reza
    Lohrabian, Vahid
    Aghamiri, Mahmoud Reza
    Robatjazi, Mostafa
    ARCHIVES OF IRANIAN MEDICINE, 2016, 19 (03) : 186 - 191
  • [22] Investigation of TG-43 Dosimetric Parameters for 192Ir Brachytherapy Source Using GATE Monte Carlo Code
    Joya, Musa
    Nedaie, Hassan Ali
    Geraily, Ghazale
    Rezaei, Hadi
    Bromand, Awaz
    Ghorbani, Mahdi
    Sheikhzadeh, Peyman
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 268 - 273
  • [23] Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source
    Simiele, S.
    Palmer, B.
    DeWerd, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3625 - 3625
  • [24] Monte Carlo calculated TG-60 dosimetry parameters for the β- emitter 153Sm brachytherapy source
    Sadeghi, Mahdi
    Taghdiri, Fatemeh
    Hosseini, S. Hamed
    Tenreiro, Claudio
    MEDICAL PHYSICS, 2010, 37 (10) : 5370 - 5375
  • [25] Impact of magnetic fields on calculated AAPM TG-43 parameters for 192Ir and 60Co HDR brachytherapy sources: A Monte Carlo study
    Ranjbar, Sahar
    Gholami, Somayeh
    Longo, Francesco
    Sharp, Ryan
    Meigooni, Ali S.
    APPLIED RADIATION AND ISOTOPES, 2020, 159
  • [26] Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapy
    Vijande, Javier
    Ballester, Facundo
    Ouhib, Zoubir
    Granero, Domingo
    Carmen Pujades-Claumarchirant, M.
    Perez-Calatayud, Jose
    BRACHYTHERAPY, 2012, 11 (06) : 528 - 535
  • [27] Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources
    Safigholi, Habib
    Chamberland, Marc J. P.
    Taylor, Randle E. P.
    Martinov, Martin P.
    Rogers, D. W. O.
    Thomson, Rowan M.
    MEDICAL PHYSICS, 2023, 50 (03) : 1928 - 1941
  • [28] A discretized approach to determining TG-43 brachytherapy dosimetry parameters:: case study using Monte Carlo calculations for the MED3633 103Pd source
    Rivard, MJ
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (06) : 775 - 782
  • [29] Polymer gel dosimetry for the TG-43 dosimetric characterization of a new 125I interstitial brachytherapy seed
    Papagiannis, P.
    Pantelis, E.
    Georgiou, E.
    Karaiskos, P.
    Angelopoulos, A.
    Sakelliou, L.
    Stiliaris, S.
    Baltas, D.
    Seimenis, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (08): : 2101 - 2111