Experimental Investigation of the Behavior of a Lattice Steel Column Repaired with Pultruded GFRP Profiles

被引:7
|
作者
Zhan, Yang [1 ]
Wu, Gang [1 ]
Yang, Li-Sheng [2 ]
机构
[1] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Sch Civil Engn, Nanjing 210096, Jiangsu, Peoples R China
[2] Jiangsu Elect Power Design Inst, Nanjing 211102, Jiangsu, Peoples R China
关键词
Lattice steel structures; Pultruded GFRP profiles; Repair; GFRP-to-steel bolted joints; Joint slippage; MEMBERS; DESIGN;
D O I
10.1061/(ASCE)CF.1943-5509.0000600
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a series of joint tests and full-scale structural tests were performed to assess the effectiveness of pultruded glass fiber-reinforced polymer (GFRP) profiles for rehabilitating lattice steel columns. The data for the displacements and strains of typical members were recorded. The experimental results showed that the failure modes are generally identical for the original column, the column restored using angles, and the column that adopted the stiffer GFRP-to-steel bolted joints (using steel cover plates, bolts, and nuts) repaired with pultruded GFRP sections. In contrast, the failure pattern of the column that used the ordinary GFRP-to-steel bolted joints (only using bolts and nuts) was not the same. Additionally, the ultimate strength of the specimen that employed the stiffer GFRP-to-steel connections was slightly higher than that of the specimen retrofitted by angles, and the ultimate capacity of the sample that adopted the ordinary GFRP-to-steel connections was significantly lower than that of the sample restored by angles because of the premature failure of the ordinary GFRP-tosteel connections. Additionally, better coordination in the working capacity of the GFRP members was exhibited by the restored structure. Furthermore, joint slippage dramatically decreased the stiffness of the structure, and its influence on the load-bearing capacity and failure mode is not obvious if the structure is subjected to the transverse loading. The conclusion is that pultruded GFRP profiles can be used for retrofitting of lattice steel structures and that the performance of GFRP-to-steel connections is a key factor in this novel method. This preliminary investigation into the feasibility of using pultruded GFRP profiles in the repair of lattice steel structures shows promising results and provides a basis for the development of other FRP shapes for application in the rehabilitation of lattice steel structures. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Design and Experimental Investigation of a new-style Pultruded GFRP Mid- Beam
    Zhang, Wei
    Zhang, Mingyi
    Gao, Litang
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 388 - 392
  • [32] Experimental Investigation of Long Term Seawater Durability and Shear Properties of Pultruded GFRP Composite
    Moyeenuddin Ahmad Sawpan
    Journal of Polymers and the Environment, 2021, 29 : 3574 - 3586
  • [33] Experimental Investigation of Physical and Mechanical Characteristics of Pultruded/Hand Lay-Up GFRP Thin-Walled Structural Sections and GFRP Pultruded Ribbed Rebars
    Mehra, Ankit Singh
    Singh, Shamsher Bahadur
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024,
  • [34] Experimental and Numerical Investigation on the Behavior of Eccentrically Loaded Hybrid Steel and GFRP RC Columns
    Haitham Al-Thairy
    Marwa Al-hamzawi
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2023, 47 : 2689 - 2716
  • [35] Experimental and Numerical Behavior of Encased Pultruded GFRP Beams under Elevated and Ambient Temperatures
    Mahmood, Enas M.
    Ibrahim, Teghreed H.
    Allawi, Abbas A.
    El-Zohairy, Ayman
    FIRE-SWITZERLAND, 2023, 6 (05):
  • [36] Creep behavior of pultruded GFRP elements - Part 1: Literature review and experimental study
    Sa, Mario F.
    Gomes, Augusto M.
    Correia, Joao R.
    Silvestre, Nuno
    COMPOSITE STRUCTURES, 2011, 93 (10) : 2450 - 2459
  • [37] An experimental study of the behavior of connections for pultruded GFRP I-beams and rectangular tubes
    Smith, SJ
    Parsons, ID
    Hjelmstad, KD
    COMPOSITE STRUCTURES, 1998, 42 (03) : 281 - 290
  • [38] Exterior weak-axis beam-to-column bolted connections between GFRP I-shaped pultruded profiles using stainless steel cleats
    Mathew, Ajith
    Gonilha, Jose A.
    Nadir, Yashida
    Ye, Yuyi
    ENGINEERING STRUCTURES, 2024, 314
  • [39] Fire protection systems for building floors made of pultruded GFRP profiles Part 1: Experimental investigations
    Correia, Joao R.
    Branco, Fernando A.
    Ferreira, Joao G.
    Bai, Yu
    Keller, Thomas
    COMPOSITES PART B-ENGINEERING, 2010, 41 (08) : 617 - 629
  • [40] EXPERIMENTAL BEHAVIOR OF STEEL COLUMN BASES
    HON, KK
    MELCHERS, RE
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1988, 9 (01) : 35 - 50