Novel Instrument for Temperature Measurements in Borehole Heat Exchangers

被引:11
|
作者
Aranzabal, Nordin [1 ]
Martos, Julio [1 ]
Steger, Hagen [2 ]
Blum, Philipp [2 ]
Soret, Jesus [1 ]
机构
[1] Univ Valencia, Dept Elect Engn, E-46100 Burjassot, Spain
[2] Karlsruhe Inst Technol, Inst Appl Geosci AGW, D-76131 Karlsruhe, Germany
关键词
Borehole heat exchanger (BHE); embedded operating system; field-programmable gate array (FPGA); ground source heat pump (GSHP); open source; system on a chip (SoC); temperature profile; thermal response test (TRT); THERMAL RESPONSE TEST; GROUNDWATER-FLOW; NUMERICAL-ANALYSIS; SYSTEMS; VALIDATION; SIMULATION; MODELS; TESTS; FIELD;
D O I
10.1109/TIM.2018.2860818
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The thermal response test (TRT) is the standard method for characterizing the thermal properties of the ground and those of a borehole heat exchanger (BHE). During the TRT, the inlet and outlet temperatures of the BHE are monitored. However, this test typically considers the ground as a homogeneous, isotropic, and infinite media, and therefore, it only determines the bulk and effective parameters, such as effective thermal conductivity and thermal borehole resistance. Hence, the enhanced TRT protocols are necessary where the depth-dependent temperatures are measured to estimate depth-specific thermal properties. Thus, a novel instrument with a data logger to automatically obtain the temperature measurements along the BHE is introduced. This device is based on a Zynq-7000 all programmable system on a chip. It has a dual-core central processing unit and a field-programmable gate array on one chip, thus providing a versatile architecture that reduces cost and improves efficiency in comparison with other systems of similar characteristics. This paper describes the implemented hardware and software developments that range from user interface application to a free-distribution operating system based on an embedded Linux. The proposed instrument can be easily incorporated throughout a TRT, and the nonspecialized staff can remotely manage or visualize the results through a menu-driven interface. The device is tested in a specific BHE installation and validated with standard Pt100-temperature-sensors. The results are comparable and, therefore, demonstrate the applicability of this novel instrument called Geowire.
引用
收藏
页码:1062 / 1070
页数:9
相关论文
共 50 条
  • [22] Geotechnical considerations in the design of borehole heat exchangers
    Zymnis, Despina M.
    Whittle, Andrew J.
    CANADIAN GEOTECHNICAL JOURNAL, 2021, 58 (09) : 1247 - 1262
  • [23] Optimization of the utilization of deep borehole heat exchangers
    Pan, Sheng
    Kong, Yanlong
    Chen, Chaofan
    Pang, Zhonghe
    Wang, Jiyang
    GEOTHERMAL ENERGY, 2020, 8 (01)
  • [24] Uncertainty in numerical models of borehole heat exchangers
    Ruehaak, Wolfram
    Steiner, Sarah
    Welsch, Bastian
    Sass, Ingo
    GRUNDWASSER, 2015, 20 (04) : 243 - 251
  • [25] Efficient numerical modeling of borehole heat exchangers
    Al-Khoury, R.
    Koelbel, T.
    Schramedei, R.
    COMPUTERS & GEOSCIENCES, 2010, 36 (10) : 1301 - 1315
  • [26] Temperature distribution in a field of long Borehole Heat Exchangers (BHEs) subjected to a monthly averaged heat flux
    Zanchini, E.
    Lazzari, S.
    ENERGY, 2013, 59 : 570 - 580
  • [28] Heat transfer analysis of short helical borehole heat exchangers
    Zarrella, A. (angelo.zarrella@unipd.it), 1600, Elsevier Ltd (102):
  • [29] Heat transfer analysis of short helical borehole heat exchangers
    Zarrella, Angelo
    De Carli, Michele
    APPLIED ENERGY, 2013, 102 : 1477 - 1491
  • [30] A novel solution for vertical borehole heat exchangers in multilayered ground with the Robin boundary condition
    Guo, Y.
    Zhao, J.
    Liu, W. V.
    APPLIED THERMAL ENGINEERING, 2024, 255